• Title/Summary/Keyword: ozone treatments

Search Result 58, Processing Time 0.022 seconds

Sludge reduction by Enzyme Pretreatment (효소 전처리를 통한 슬러지 저감)

  • 김정래;심상준;최수형;염익태
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.93-97
    • /
    • 2004
  • We investigate the effect of enzyme pretreatment using protease, carbohydrase, and lipase on improvement of sludge treatment efficiency by measuring SCOD and TCOD. The enzyme-pretreatment increases SCOD of excess sludge. In addition, the amount of sludge reduction during digestion, in terms of SCOD and TCOD, are enhanced by enzyme-pretreatment. Among pretense, carbohydrase, and lipase, pretense showed the best enhancement of the sludge treatment efficiency. Sludge digestion followed by ozone and enzyme treatments showed more effective sludge treatment when compared with ozone treatment alone. Therefore, we expect that enzyme pretreatment can be used as a useful tool for enhancing the sludge treatment efficiency.

Growth Inhibition against Contaminants in Aseptic Chocolate Milk Using Physicochemical Methods (물리.화학적 처리에 의한 멸균 초콜릿 우유 오염균의 생육억제 효과)

  • Choi, Moon-Kyoung;Yoon, So-Young;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Lee, Chung-Jo;Jung, Ji-Yeon;Kwak, Ji-Hee;Kim, Min-Ji;Kim, Dong-Hyun;SunWoo, Chan;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1157-1163
    • /
    • 2011
  • This study was conducted to investigate the cause of microbiological contaminants in aseptic chocolate milk and evaluate the effect of a physicochemical treatment on the growth inhibition of isolated bacterial strains. The bacterium isolated from aseptic chocolate milk was identified as Bacillus lentus and was named B. lentus M1. In the heat and pH treatment, the growth of B. lentus was inhibited at 110$^{\circ}C$ for >15 min and at pH's <5 and >10. An electrolyzed water treatment against B. lentus M1, revealed 5 mm growth past the inhibition zone. The effect of ozone gas on B. lentus M1 growth was evaluated using viable cell counts. When the initial number of B. lentus M1 was $10^2$ and $10^3$ CFU, the bacteria were completely suppressed by ozone gas treatment for 10 and 30 min, respectively. In a microwave treatment, B. lentus M1 was sterilized following microwave treatment for 1 min. As the result of ${\gamma}$-irradiation against B. lentus M1, numbers decreased as the ${\gamma}$-irradiation dosage increased. These results show the growth inhibition effects against contaminants in aseptic chocolate milk using physicochemical treatments.

Investigation of the Optimum Operational Condition of Bio-Hydrogen Production from Waste Activated Sludge (폐활성 슬러지로부터 생물학적 수소 생산을 위한 최적 조건 연구)

  • Kim, Dong-Kun;Lee, Yun-Jie;Yu, Myong-Jin;Pak, Dae-Won;Kim, Mi-Sun;Sang, Byoung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.362-367
    • /
    • 2006
  • Waste activated sludge(WAS) collected from domestic wastewater treatment plant is biomass that contains large quantities of organic matter. However, relevant literature show that the bio-hydrogen yield using WAS was too low. In this study, the effect of pretreatment of WAS on hydrogen yield was investigated. Pretreatment includes acid and alkali treatments, grinding, heating, ozone and ultrasound methods. After pretreatment organic matters of WAS were solubilized and soluble chemical oxygen demand(SCOD) was increased by 14.6 times. Batch experiments were conducted to investigate the effects of pre-treatment methods and buffer solution, hydrogen partial pressure, and sodium ion on hydrogen production from WAS by using heated anaerobic mixed cultures. Experimental results showed that addition of buffer solution, efficient pre-treatment method with alkali solution, and gas sparging condition markedly increased the hydrogen yield to 0.52 mmol $H_2/g$-DS.

Effect of Freezing on the Physicochemical Properties of Semi-dried Red Pepper (냉동조건에 따른 반건조 홍고추의 물리.화학적 특성 변화)

  • Kim, Bo-Yeon;Lee, Kyoung-Hae
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.362-370
    • /
    • 2009
  • Quality changes in semi-dried red pepper (SRP) treated with ozone water were observed upon storage (at $-18^{\circ}C$) after freezing at $-10^{\circ}C$, $-20^{\circ}C$, and $-40^{\circ}C$. Drip loss after treatment was greater than in control peppers, but no significant difference was evident between treatments (p<0.05). We observed that differences between samples decreased as storage time increased. Texture after treatment did not change significantly over a 3-month period. The redness (a-value) after treatment was greater than in the control, but no sample showed significant color alteration after the 3-month period. The capsaicinoid content decreasedas storage time increased, and was also affected by the freezing temperature. However, carotenoid content was not influenced by freezing or storage temperature. Ascorbic acid and free sugar contents showed decreases of 47% and 6.5%, respectively, after semi-drying. The results of sensory evaluation indicated no significant difference between samples in terms of color appearance.

Control Indian meal moth Plodia interpunctella by gas treatment

  • Han, Gyung Deok;Kwon, Hyeok;Jin, Hyun Jung;Kum, Ho Jung;Kim, Bo Hwan;Kim, Wook
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.45-45
    • /
    • 2017
  • The Indian meal moth, Plodia interpunctella, is one of the most important pests of stored food in the food processing industry worldwide. To control the Indian meal moth, methyl bromide, phosphine, high carbon dioxide, sulfuryl fluoride and plant essential oil fumigation have been considered. However, these treatments have disadvantages. For example, depleting the ozone layer, showing resistance in insect, low control efficacy or need high cost for treatment. Chlorine dioxide ($ClO_2$) is strong disinfectant and insecticide. The gas caused a malfunction in enzymes. The oxidative stress induced by $ClO_2$ gas treatment damaged to a physiological system and all life stages of P. interpunctella. The gaseous $ClO_2$ is a convincing alternative to methyl bromide for controlling P. interpunctella. The gaseous $ClO_2$ was generated by a chlorine dioxide generator (PurgoFarm Co., Ltd., Hwasung, Korea). It generated highly pure $ClO_2$ gas and the gas blown out through a vent into a test chamber. Gas entry to the chamber was automatically controlled and monitored by a PortaSene II gas leak detector (Analytical Technology, Collegeville, PA, USA). The properly prepared eggs, larvae, pupae, and adults of P. interpunctella were used in this experiment. Data were analyzed using SAS 9.4. Percentage data were statistically analyzed after arcsine-root transformation. Analysis of variance was performed using general linear model, and means were separated by the least significant difference test at P < 0.05. Fumigation is an effective management technique for controlling all stages of P. interpunctella. We found that $ClO_2$ gas treatment directly effects on egg, larvae, pupae and adults of P. interpunctella. The gas treatment with proper concentration for over a day achieved 100 % mortality in all stages of P. interpunctella and short time treatment or low concentration gas treatment results showed that the egg hatchability, pupation rate, and adult emergency rate were lowered compare with untreated control. Also, abnormal pupae or adult rate were increased. Gaseous $ClO_2$ treatment induced insecticidal reactive oxygen species (ROS), and it resulted in fatal oxidative stress in P. interpunctella. Taken together, these results showed that exposure proper concentration and time of the gas control all stages of P. interpunctella by inducing fatal oxidative stress. Further studies will be required to apply the gas treatment under real-world condition and to understanding physiological reaction in P. interpunctella caused by oxidative stress.

  • PDF

Effects of Ozonated Water Treatment on Pesticide Residues and Catechin Content in Green Tea Leaves (녹차의 잔류농약과 카테친 함량에 미치는 오존수 처리 효과)

  • Jung, Kyung-Hee;Seo, Il-Won;Nam, He-Jung;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.265-270
    • /
    • 2008
  • This study examined the effects of treating green tea leaves with ozonated water by evaluating pesticide residue levels and catechin content. The pesticide residue levels of tea leaves treated with carbendazim, captain, diazinon, fenthim, dichlorvos, and chlorpyrifos ranged from 43.2 to 48.2 ppm. For leaves treated by soaking or watering with tap water, or with 0.25 ppm of ozone water for 30 min. Pesticide residue levels were reduced by 24.0-30.2%, 30.3-33.6%, 52.4-70.5%, and 65.5-80.2%, respectively. No major differences in catechin content were observed in the leaves according to the soaking and rinsing treatments using ozonated or tap water.

Effect of Physicochemical Treatment on Growth Inhibition of Hanseniaspora uvarum Y1 from Yogurt (물리·화학적 처리에 의한 요구르트 오염균의 생육 억제효과)

  • SunWoo, Chan;Lee, So-Young;Yoon, So-Young;Jung, Ji-Yeon;Kim, Koth-Bong-Woo-Ri;Lee, Chung-Jo;Kwak, Ji-Hee;Kim, Min-Ji;Kim, Dong-Hyun;Jung, Seul-A;Kim, Hyun-Jee;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.12
    • /
    • pp.1781-1786
    • /
    • 2011
  • This study was conducted to investigate the cause of microbiological contamination in yogurt and evaluate the effect of physicochemical treatment on the growth inhibition of Hanseniaspora uvarum isolated from yogurt. The yeast strain Hanseniaspora uvarum Y1 was subjected to heat and pH treatments. H. uvarum Y1 was killed at $70^{\circ}C$ and $80^{\circ}C$ after 15 min and survived in a wide pH range from pH 2 to 9. However, it did not survive under pH 1 and over pH 10. In a disk diffusion susceptibility test on H. uvarum Y1, a clear zone (5 mm) of growth inhibition was observed upon treatment with electrolyzed water. The effect of ozone gas on the growth of H. uvarum Y1 was evaluated by viable cell count. Initial cell numbers of $10^2$ and $10^3$ CFU/mL of H. uvarum Y1 were completely killed by treatment for 10 and 30 min, respectively. H. uvarum Y1 was also sterilized by microwave treatment for 1 min. When treated with gamma-irradiation, the rate of killing of H. uvarum Y1 was proportional to the irradiation dose. and complete killing occurred at a dose of 50 kGy.

Efficacy of Listeria Innocua Reduction on Enoki Mushrooms by Utilization of an Air Sterilization Device (공기 살균 장치 적용 팽이버섯 재배사의 Listeria Innocua 저감 효과)

  • Lee, Hyun-Dong;Yu, Byeong-Kee;Seo, Da-Som;Kim, Se-Ri;Lee, Chan-Jung;Kwak, Kang-Su
    • Journal of Mushroom
    • /
    • v.19 no.3
    • /
    • pp.210-215
    • /
    • 2021
  • For sterilization of microorganisms of the Listeria genus contaminating enoki mushroom, pilot mushroom grower equipped with air sterilization devices were developed. Sterilization experiments were performed using physical and chemical treatments. Internal temperature and humidity were controlled, maintaining 6.62℃±0.30 in the upper shelves, 6.46℃±0.24 in the middle shelves, and 6.48℃±0.25 in the lower shelves. Humidities were 79.97%±4.42, 79.43%±4.06, and 79.94±4.30%, respectively, with a temperature setting of 6.5℃, and a relative humidity of 75%. A suitable enoki mushroom cultivation stage for air sterilizer application was during the growth stage, with temperature in the 6.5~8.5℃ range, and humidity of 70~80%. At these same internal conditions, the ozone concentration in the mushroom cultivator was found to be 160 ppb during ion-cluster generator operation. After physical sterilization, the Listeria innocua survival rate was 0.1 to 0.9% using ion cluster sterilization, and 9.3 to 10.6% using UV air sterilization. The Listeria innocua survival rates on different materials were 9.3~10.6% on the metal specimen, and 9.9~16.2% on the plastic wrapper. The survival rate was particularly high on the rough side of the plastic wrapper. Ion cluster air sterilization is a labor-saving and effective method for suppressing the occurrence of Listeria bacteria on mushroom growers walls and shelves. For the plastic wrapper, chemical sterilization is more effective than physical sterilization.