• Title/Summary/Keyword: ozone in Korea

Search Result 775, Processing Time 0.046 seconds

Effect of Air Pollution on Emergency Room Visits for Asthma : a Time Series Analysis (대기오염과 천식발작의 관련성에 관한 시계열적 연구)

  • Ju, Young-Su;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.1
    • /
    • pp.61-72
    • /
    • 2001
  • Objectives : To evaluate the hypothesis that increasing ambient levels of ozone or particulate matter are associated with increased emergency room visits for asthma and to quantify the strength of association, if any, between these. Methods : Daily counts of emergency room visits for asthma, air quality, and weather data were collected from hospitals with over 200 beds and from monitoring Stations in Seoul, Korea from 1994 through 1997. Daily counts of emergency mom visits for asthma attack were analyzed using a general additive Poisson model, with adjustment for the effects of secular trend, seasonal variation, Sunday and holiday, temperature, and humidly, according to levels of ozone and particulate matter. Results : The association between daily counts of emergency room visits for asthma attack and ozone levels was statistically significant in summer(from June to August), and the RR by unit inclement of 100 ppb ozone was 1.30(95% CI = $1.11\sim1.52$) without lag time. With restriction of the period from April to September in 1996, the RR was 1.37(95% CI = $1.06\sim1.76$), and from June to August in 1995, the RR was 1.62(95% CI = $1.12\sim2.35$). In the data for children$(5\sim14yr)$, the RR was 2.57(95% CI = $1.31\sim5.05$) with restriction of the period from April to September in 1997. There was no Significant association between TSP levels and asthma attacks, but a slight association was seen between PM10 levels and asthma attacks in a very restricted period. Conclusion : There was a statistically significant association between ambient levels of ozone and daily counts of emergency room visits for asthma attack. Therefore, we must make efforts to effectively minimize air pollution, in order to protect public health.

  • PDF

The decolorization treatment of dye solutions by ozone (Ozone을 이용한 염료용액의 탈색 처리)

  • Lee, Soo-Kyung;Cho, Hwan;Jeong, Hee-Cheon
    • Textile Coloration and Finishing
    • /
    • v.8 no.5
    • /
    • pp.17-24
    • /
    • 1996
  • Dye solutions were tested in order to find the optimal condition of ozonation and determine the progress of degradation, i.e., change of the parameters characterizing the dye solutions. From the results of our experiment we can conclude that almost all of the color was removed within a 10 minute time period. An ozone oxidation results in the effective removal of COD(60%). but the elimination of the total organic carbon(TOC) was not successful, only about 15~40% of TOC was removed from dyeing wastewater in 30 minutes. The color removal is much effective in using ozonation method.

  • PDF

The comparison and observation of Stratospheric ozone using Ozone LIDAR and Ozone sonde in Korean Peninsula (오존라이더와 오존존데의 공동관측을 통한 한반도 성층권 오존 비교)

  • 방소영;조경숙;박기준;최재천;최병철;김성균;김정식;손주형;송동일
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.239-240
    • /
    • 2003
  • 인간활동에 의해 오존이 감소하고 있다는 사실이 1985년 남극지역 전량오존에 관한 보고서로 처음 밝혀진 이후 계속적으로 북극지역과 중위도 지역에서도 동일한 현상이 일어나고 있다고 보고되고 있다(WMO/GAW No.143). 세계기상기구에서는 지상부근의 오존 또는 대기중의 오존전량에 대해서는 1950년대에 처음으로 전지구적차원의 오존관측이 실시되었으며, 1980년대초에 세계기상기구가 발족시킨 전지구오존관측시스템(Global Ozone Observing System, GO$_3$OS)에 의해 전세계적인 관측을 실시하고 있고 있다. (중략)

  • PDF

Response of Ozone Sensitivity in Open-Pollinated Families of Pinus densiflora Seedlings (소나무 풍매차대묘(風媒次代苗)의 가계간(家系間) 오존에 대한 민감성(敏感性) 반응(反應))

  • Lee, Jae-Cheon;Oh, Chang-Young;Han, Sim-Hee;Kim, Jang-Su
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.191-196
    • /
    • 2005
  • This studies were conducted to compare ozone sensitivity among half-sib families of Japanese red pine (Pinus densiflora S. et Z.). 90 families were exposed in walk-in type chambers to charcoal-filtered air and 100 ppb ozone for 8 hours daily, 5 consecutive months. We surveyed the foliar injury, Relative DRC (diameter at root collar) growth and relative dry weight after fumigation. After 5 months of exposure, foliar injury ranged from 1.9% at tolerant group to 15.2% at sensitive group. Relative DRC growth rates showed increased 12% at tolerant group, but reduced 23% at sensitive group. Total dry weight increased 17% at tolerant group, otherwise reduced by 33% at sensitive group, relative to the control. The root biomass showed more sensitive than the other part biomass. On the basis of the results of these screening studies, families Kangwon 04, 16, 26, 27 and 73 were determined to be tolerant; Kangwon 40, 52, 83, Gyeonggi 01 and Gyeongbuk 20 to be sensitive to ozone. Considerable genetic variation in ozone responses occurred, as shown by differences in sensitivities among families and among groups. These results indicate that tolerant groups of P. densiflora exhibited a high degree of resistance to ozone pollution injury.

Study on the Removal of Fluorescent Whitening Agent by Pretreatment Ozone Oxidation for MBR Process Application (MBR 공정 적용을 위한 전처리 오존산화에 의한 형광증백제 제거 연구)

  • Choi, Jang-Seung;Ryu, Seung-Han;Shin, Dong-Hun;Lee, Jae-Hun;Lee, Soo-Chol;Kim, Sung-Gi;Ryu, Jae-Young;Shin, Won-Sik;Lee, Seul-Ki;Park, Min-Soo
    • Textile Coloration and Finishing
    • /
    • v.29 no.1
    • /
    • pp.11-17
    • /
    • 2017
  • In this study, ozone oxidation experiment was carried out for the removal of fluorescent whitening agent which is widely used in textile dyeing and paper industry. The stilbene fluorescent whitening agent has been industrialized since the earliest, and the amount of current production is the highest. Due to the characteristics of the fluorescent whitening agent that can not be removed by conventional wastewater treatment methods, the fluorescent whitening agent in wastewater treatment has difficulty in using as recycled water in the process. Pre-treatment ozone oxidation experiment was conducted prior to the introduction of Membrane Bio Reactor(MBR) treatment process by converting biodegradable materials into biodegradable materials. The removal efficiencies of fluorescent whitening agents, a diaminostilbenedisulfonic acid derivative by ozone oxidation were evaluated by $UV_{254}$ Scan, $COD_{Mn}$, T-N and color using a synthetic wastewater sample ($COD_{Mn}=433.0mg/{\ell}$) and paper and paper mill wastewater ($COD_{Mn}=157.2mg/{\ell}$).

Variations of Ground-lever Ozone Concentration in Korea during 1991 to 1993 (1991 - 1993년 사이 우리나라의 오존 농도 변화)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.55-66
    • /
    • 1996
  • One-hour average concentrations of ground-level ozone from around 80 monitoring stations in Korea during 1991 to 1993 were analyzed to examine characteristics of the ozone concentration variations. Two types of variations were observed: one was for the Capital area typified by Kwanghwmun, and the other was for the south and east seashore region typified by Tongkwangyang. In the Capital area including Seoul, Inchon, Kyonggi-do and Chunchon, mean daily 1-hout maximum was the highest in June following high monthly averages in spring. But frequent precipitation prevented further rise of daily maximum in July and August even though there were frequent episodes of high concentration exceeding 100ppb. In the south and east seashore region, average concentration was the highest throughout the year, and daily maximum and minimum simultaneously changed owing to small contributions from photochemical reactions. The typical annual variation was spring peak, summer down, and fall rise. Spring peak accompanied an usual observations of background variations at remote sites in the Northern Hemisphere. Riess of average and daily maximum with lower daily minimum in fall were attributable to photochemical reactions.

  • PDF

Trends and Factors of Ozone Concentration Variations in Korea (우리나라의 오존도 변화 추이와 주요 인자)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.607-623
    • /
    • 2000
  • Major trends of ozone concentration variations in Korea were investigated by using observation data from around 100 stations for the period of 1991∼1997. In addition, important regulating those variations were inferred. Three measures such as the number of days exceeding 80ppb, the 95th percentile of daily maxima, and the annual average concentration were used for the analysis of multi-scale ozone concentration variations. Three areas in the southwest (Sosan, Mokpo, and Cheju) of which monitoring has been operated since 1995 showed the highest annual average concentrations over; this was noted because of the high annual average in the Yosu area in the early 1990s. Large increases in annual average concentrations were observed along the relatively cleaner areas connecting Kangnung and Kwangju(northeast to southwest), in contrast to polluted areas connecting Seoul and Pusan(northeast to southeast). Both the number of exceedance days and the daily maximum concentration were nearly constant in the Greater Seoul Area in spite of interannual flucturations associated with year-to-year changes in air temperature. Within the Greater Seoul Area, all three measures usually showed the same trend; they decreased in the middle and west and increased in the east and northeast. All three measures including the number of exceedance days increased largely at Sillim where the average concentration was high but no exceedance days were recorded in the early 1999s, Nationwide ozone concentration variations appear to be determined by the competitive influence of long-range transport and local urban emissions, Within the city including the Greater Seoul Area, changes in emission which accompany changes in population and in the number if vehicles ( in the process of urban development) were found to be important components of ozone concentration variations.

  • PDF

A Study on Removal of Organic Matter and Chromaticity from Urine Using Chemical Oxidization Process (화학적 산화공정을 이용하여 소변의 색도 및 유기물 처리를 통한 재이용 기술 연구)

  • Shin, Sung-Hoon;Jung, Jong-Tai;Cho, Yong-Chul
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.109-115
    • /
    • 2018
  • This study was conducted to solve the water shortage problem by reclaiming urine from homes or public places and using it as cleaning water for toilets. The process used in this experiment is a chemical oxidation process combining ozone, hydrogen peroxide, and UV. We set the key substance that is to be removed as chromaticity and conducted the experiment to remove it. If the quantity or concentration of injected ozone, UV, and hydrogen peroxide is insufficient, then the chromaticity will initially increase due to low oxidizing power, and will later decrease. In addition, the efficiency of removing chromaticity appeared to be higher, depending on the quantity of ozone injected, for medium concentrated urine than highly concentrated urine. However, the absolute quantity of removed chromaticity was about 68% higher for highly concentrated urine, when 16 g/hr of ozone was injected. The higher the pH level, the reaction time and efficiency of removing chromaticity were higher, and in normal conditions, in reference to a pH of 8.55, there was a 6% difference in efficiency between a pH level of 5.05 and a pH level of 10.12. Finally, when processing urine through an ozone-only process, COD decreased steadily over time, but DOC did not decrease. This is because ozone reacts selectively with organic matter.

Studies on the Ozone Resistance and Physical Properties of SBR/EPDM Blend Compound due to EPDM Content Variation (EPDM 함량 변화에 따른 SBR/EPDM 블렌드 혼합물의 내오존성과 물리적 성질에 관한 연구)

  • Ha, Ki-Ryong;Lee, Jong-Cheol;Kim, Tae-Geun;Hwang, Ki-Seob
    • Elastomers and Composites
    • /
    • v.43 no.1
    • /
    • pp.8-17
    • /
    • 2008
  • Styrene-butadiene rubber(SBR) has good abrasion resistance, miscibility, and anti-vibration property. however, it is easily damaged by ozone and swelled by hydrocarbon fluids because of unsaturation part in main chain, that causes loss of visco-elasticity and reduction of product's life cycle. Therefore, object of this study is to cope with this problem. SBR is blended with various proportion of ethylene-propylene-diene terpolymer(EPDM), which has excellent ozone and oxygen resistance, to improve physical properties and ozone resistance, and diverse analytical techniques are used to measure morphology, glass transition temperature$(T_g)$, ozone-resistance, degradation temperature, static spring constant, hardness for considering a suitability for anti-vibration industrial product. We found that the blend consisting of SBR 70% and EPDM 30% showed no crack after ozone test and good miscibility between SBR and EPDM from this study.

Effect of Advanced Treatment Process for Residual Chlorine Decay and THM Formation in Water Distribution System (고도처리공정이 관로 내 잔류염소 감소 및 THM 생성에 미치는 영향)

  • Lee, Doo-Jin;Kim, Young-Il;Kim, Sung-Su;Lee, Kyung-Hyuk;Park, Hyun-A
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.419-424
    • /
    • 2007
  • According to increase of consumer's desire for clean tap water, advanced treatment processes include with membrane, ozone, and granular activated carbon(GAC) were introduced. In order to evaluate the effect of advanced treatment processes for residual chlorine decay and trihalomethane(THM) formation in water distribution system, dissolved organic matter(DOC) removal of each advanced treatment process was investigated. The residual chlorine decay and THM formation using bottle tests were also evaluated. $UV_{254}$ removal in all advanced treatment was better than DOC removal. Especially, DOC by ozone treated was removed as 4% in contrast with sand filtered water, but $UV_{254}$ was removed about 17%. This result might be due to convert from hydrophobic DOC to hydrophilic DOC by ozonation. Ozone/GAC process was most effective process for DOC removal. The residual chlorine decay constants in treated water by sand filtration, ozonation, GAC adsorption, and ozone/GAC processes were 0.0230, 0.0307, 0.0117 and 0.0098 $hr^{-1}$, respectively. The sand filtered water was produced 81.8 ${\mu}g/L$ of THM after 190 hours of reaction time, as the treated water by ozone, GAC, and Ozone/GAC was less produced 6.0, 26.2, 30.3% in contrast with sand filtered water, respectively. Consequently, the durability of residual chlorine and reduction of THM formation were improved by advanced treatment processes.