A Study about Ozonized Water Making that Use $O_3$ (오존화 기체를 이용한 오존수 제조에 관한 연구)

  • Park, Hyun-Mi;Lee, Chang-Ho;Lee, Sang-Geun;Song, Hyun-Jig;Yoon, Byeng-Han;Lim, Chang-Ho;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.339-342
    • /
    • 2004
  • It is research about special quality of ozone gas concentration and dissolved ozone concentration that show according to change of flow rate when liquefied ozone gas in water. If increase flow rate of ozone gas, ozone concentration increases being proportional and amount to fixed flow rate, dissolved ozone concentration was measured low. When ozone concentration How rate 1000 [ppm], dissolved ozone concentration smelted to flow rate 1.5[Q] for 28 [min] is $0.1740{\sim}0.8020[mg/l]$. Could know that half-life is most short by 3 minutes 8 seconds in flow rate 1.5 [Q]. And ozone smelted 20 minutes later after half-life measurement became disjointing all.

  • PDF

The Characteristics of the Ozonation of the Phenol Wastewater in the Continuous PCR and BCR (연속식 PCR과 BCR에서 기$cdot$액 접촉 방법 및 주입 오존 유량에 따른 페놀 폐수의 오존 처리특성)

  • Kim, Yong-Dai;Ahn, Jae-Dong;Lee, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • The main objectives of this research program were to study the ozonation characteristics of phenol wastewater in the continuous packed colamn reactor(PCR) and the bubble column reactor (BCR) using ozone and to provide the fundamentals of ozonizing the phenol wastewater. Among various influencing factors that affect on phenol decomposition through the oxidation by ozone, contacting method, and ozone flow rate were chosen as reaction parameters. The results were obtained from two different types of contacting methods where the countercurrent flow was more efficient than the cocurrent flow in both the phenol removal efficiency and the ozone utilization efficiency. Furthermore, PCR showed the phenol removal efficiency 1.6 to 3% higher than that of BCR in both contacting methods, as well as the ozone utilization efficiency, suggesting that the countercurrent flow is more efficient than the cocurrent flow. The phenol removal efficiency and the ozone utilization efficiency were reduced in both reactors as the influent ozone flow rate increased. Upon varing flow rate from 0.5l/min to 2.0 l/min by 0.5 l/min, the phenol removal efficiency was reduced approximately from 8.5% to 10.5% and the ozone utilization efficiency was reduced approximately from 6% to 8% in both reactors. The performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

  • PDF

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

A Study on the Removal of Low-Concentration Ozone by means of Activated Carbon (활성탄을 이용한 저농도 오존(OZONE)제거에 관한 연구)

  • 양원호;최경호;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.57-63
    • /
    • 1997
  • This study was carried out to find the adverse health effects of ozone by papers, the potential indoor sources of ozone by papers, and then the removal mechanism of ozone by experiments. The exposure of individuals to excessive levels of ozone both in the industrial and ambient environment is a continuing public health concern. Ozone indoors may play a role in generating secondary pollutants that may have adverse health effects. The removal efficiency of ozone was studied by (1) the effect of concentration on breakthrough time, (2) the effect of flow rate on breakthrough time, (3) the effect of adsorbent's weight on breakthrough time, (4) the effect of temperature on breakthrough time, (5) the application of Langmuir's isotherm equation in using activated carbon. The followings are the conclusions that were derived from this study. 1. In the effect of concentration on breakthrough time, the adsorption capacity of activated carbon was inversely proportional to ozone concentratuion (0.1, 0.2, 0.3 ppm). 2. In the effect of flow rate on breakthrough time, the service life of activated carbon was inversely proportional to flow rate (2, 8, 14l/min). 3. The difference in removal efficiency of ozone between weights(100 mg and 150 mg) was seen. And when weight of activated carbon was 100 mg and 150 mg, pressure loss was 4-5mmHg and 6-7mmHg, respectively. It is required to study relations among flow rate and adsorbent's weight and ventilation quantity, too. 4. Generally, Langmuir's equation, one of the oldest and most used frequently isotherm equation, applies to chemisorption. In case of ozone, when the weight of activated carbon was 70 mg and temperature 40, slope(1/a) was $6.25\times 10^{-1}$ and intercept(1/ab) was $1.9\times 10^{-4}$ (average r=0.94).

  • PDF

Surface Composition Change of UV/Ozone Modified Polypropylene (UV/오존에 의해 개질된 폴리프로필렌의 표면 조성 변화)

  • Kim, J.I.;Ryu, S.H.
    • Elastomers and Composites
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2002
  • Polypropylene is oxidized with UV/ozone as a function of UV treatment time and ozone flow rate and its surface characteristics are investigated using contart angle measurements and XPS. The aging behavior of oxidized surface is investigated under air, water and ethylene glycol as the aging media. Adhesion strength is also investigated using a lap shear test. Polar surface energy increases with increasing UV/ozone treatment time as well as ozone flow rate. No polar surface energy change is observed under water aging, while under air aging it decreases significantly within 2-3 days and reaches the close value as that of the untreated PP. Adhesion strength increases with increasing UV/ozone treatment time as well as ozone flow rate.

The Characteristics of Ozone Generation for Dielectric Barrier Discharge with Discharge Area variation (방전면적에 따른 유전체장벽 방전에 의한 오존생성 특성)

  • Lee, Chang-Ho;Park, Soong-Gyu;Kim, Jong-Hyun;Lee, Hyun-Chul;Song, Hyun-Jig;Lee, Sang-Keun;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.379-380
    • /
    • 2008
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, glass and ceramic plate tyre ozonizer have been fabricated to investigate discharge parameter(input power, flow rate of supplied gas, electrode form, etc.) effect to discharge. And the conditions of discharge parameter have been investigated for optimum ozone generation. Ozone concentration is continuously increased with increasing input power for same discharge space, and ozone yield is also increased until maximum point after that it is saturated. Ozone concentration is inversely proportional to flow rate of supplied gas but ozone generation and ozone vield characteristics are improved.

  • PDF

Development on the High Concentration Ozone Generator System for the Semiconductor Photoresist Strip Process (반도체 감광막 제거공정 적용을 위한 고농도 오존발생장치 개발)

  • Son, Young-Su;Ham, Sang-Yong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.591-596
    • /
    • 2006
  • we have been developed on the ultra high concentration ozone generator system which is the core technology in the realization of the semiconductor photoresist strip process using the ozone-vapor chemistry. The proposed ozone generator system has the structure of the surface discharge type which adopt the high purity ceramic dielectric tube. We investigate the performance of the proposed ozone generator system experimentally and the results show that the system has very high ozone concentration characteristics of $19.7[wt%/O_2]$ at the flow rate of $0.3[{\ell}/min]$ of each discharge cell. As a result of the silicon wafer photoresist strip test, we obtained the strip rate of about 400[nm/min] at the ozone concentration of $16[wt%/O_2]$ and flow rate of $8[{\ell}/min]$. So, we confirmed that it's possible to use the proposed high concentration ozone generator system for the ozone-vapor photoresist strip process in the semiconductor and FPD industry.

The Characteristics of plate type ozonizer according to voltage application method (전압인가 방식에 따른 평판형 오존발생기의 특성)

  • Lee, Chang-Ho;Kim, Jong-Hyun;Youn, Byung-Han;Kim, Ki-Chai;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.203-207
    • /
    • 2007
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, plate type ozonizer have been fabricated to investigate discharge parameter(input power, flow rate of supplied gas, electrode form, etc.) effect to discharge. And the conditions of discharge parameter have been investigated for optimum ozone generation. Ozone concentration is continuously increased with increasing input power for same discharge space, and ozone yield is also increased until maximum point after that it is saturated. Ozone concentration is inversely proportional to flow rate of supplied gas but ozone generation and ozone yield characteristics are improved.

  • PDF

Solubility Behavior of Ozone for Silicon Wafer Cleaning (실리콘 웨이퍼 세정을 위한 오존의 거동에 관한 연구)

  • Lee Gun-Ho;Kim In-Jung;Bae So-Ik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.13-17
    • /
    • 2005
  • The behavior of ozone in $NH_4OH$ was investigated to evaluate the solution as a cleaning chemical of the silicon wafer. The solubility of ozone in DI(Deionized) water increased as the oxygen flow-rate decreased and ozone generator power increased. Ozone in DI water showed solubility of 100 ppm or higher at room temperature. Ozone concentration was stabilized at the range of ${\pm}2ppm$ by controlling oxygen flow rate and ozone generator power. On the contrary, the solubility of ozone in $NH_4OH$ was very low and strongly depended on the concentration of $NH_4OH$ and pH. The redox potential of ozone was saturated within 10 minutes in DI water and decreased rapidly with the addition of $NH_4OH$. The behavior of ozone in $NH_4OH$ is well explained by redox potential calculation.

  • PDF

A Study on the Decomposition Rate of Phenol in the Batch Type Ozonation (회분식 오존 공정에서 페놀의 분해 속도에 관한 연구)

  • 안재동;강동수
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.127-132
    • /
    • 1997
  • The characteristics of the ozone treatments of phenol were studied in a laboratory scale wastewater treatment system. The ozone treatment of wastewater was carried out in a batch-type reactor. The initial pH of wastewater(7-10), volumetric flow rate(1-2l/min) and ozone concentration(20~30 mg/l) of aerating gas were considereal as experimental variables in the ozone treatment. Phenol was decomposed easily by the ozone in a batch treatment, where the rate determining step was the COD removal that is decomposition of intermediates formed by the ozonation of phenol. Phenol decomposition and COD removal could be expressed by the first order reaction for the phenol concentration and COD, respectively. Rate constants of phenol decomposition and COD removal increased with the initial pH, volumetric flow rate and ozone concentration of aeration gas. Under the present experimental condition, their relationships could be given by for the phenol decomposition $k'=4.46\times 10^{-9}[pH]_o ^{3.94}[O_3]^{1.42}Q_{O3}^{1.57}$ for the COD removal $k=2.46\times 10^{-10}[pH]_o ^{5.19}[O_3]^{1.15}Q_{O3}^{1.19}$

  • PDF