• Title/Summary/Keyword: ozone/activated carbon process

Search Result 55, Processing Time 0.026 seconds

A Study on the Decomposition of Dissolved Ozone and Phenol using Ozone/Activated Carbon Process (오존/활성탄 공정을 이용한 용존 오존 및 페놀의 분해에 관한 연구)

  • Choi, Jae Won;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.5
    • /
    • pp.490-495
    • /
    • 2012
  • The catalytic effect induced by activated carbon (AC) was evaluated during the phenol treatment using an ozone/AC ($O_{3}/AC$) process. In the case of the addition of AC to the ozone only process, the decomposition efficiency of dissolved ozone and phenol increased with increasing the amount of AC input. It was that the OH radical generated from the decomposition of dissolved ozone by AC had an effect on the removal of phenol. It was shown as the catalytic effect of AC ([$\Delta$phenol]/$[{\Delta}O_{3}]_{AC}$) in this study. The maximum catalytic effect was approximately 2.13 under 10~40 g/L of AC input. It approached to the maximum catalytic effect after 40 min of reaction with 10 and 20 g/L of AC input, while the reaction time reached to the maximum catalytic effect under 30 and 40 g/L of AC input was approximately 20 min. Moreover, the removal ratios of total organic carbon (TOC) for ozone only process and ozone/AC process were 0.23 and 0.63 respectively.

Study on the applicability of the ozone / AOP and activated carbon process for the removal of trace organic contaminants and taste odor causing substances (미량오염물질 및 맛 냄새유발물질의 제거를 위한 오존/AOP 및 활성탄 공정의 적용성에 관한 연구)

  • Ha, Jeongtae;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.155-162
    • /
    • 2015
  • This study was conducted to assess the removal characteristics of taste and odor causing compounds(2-MIB and geosmin) and micro organic matters. GAC and BAC process consisting of Ozone/AOP and activated carbon was applied. As a result, the influent concentration of 2-MIB 159 ng/L and geosmin 371 ng/L were removed 42% and 86% by ozone 1.0 mg/L, and 58%, 90% by AOP(ozone 1.0 mg/L + $H_2O_2$ 0.5 mg/L). Also it showed less than 2 ng/L effluent in GAC process and 99.8% removal efficiency in BAC process. Therefore, BAC process combining ozone/AOP and GAC is effective for persistent removal of micro organic matters, taste and odor. It is needed for optimization of Ozone/AOP process according to influent concentrations.

Phenol Removal by Ozone-Activated Carbon Hybrid Process (오존-활성탄 복합공정에 의한 페놀 제거)

  • Kim, Hwanik;Moon, Ji-Hoon;Chung, Jae Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.311-316
    • /
    • 2014
  • Effects of operating parameters such as activated carbon dose and pH on the phenol oxidation in ozone-activated carbon hybrid process were investigated through a kinetic study. Activated carbon enhanced the self-decomposition of ozone, generating $OH{\cdot}$, thus promoting phenol degradation. The pseudo-first order rate constants of phenol degradation increased and half-life of phenol decreased with activated carbon dose. The increase of pH enhanced $OH{\cdot}$ generation through chain reactions initiated by $OH^-$, therefore increasing the phenol degradation rate. TOC removal efficiency increased about 3.2 times by adding activated carbon in ozonation process.

Evaluation of Advanced Oxidation Process(AOP) as a Pretreatment Process of Biological Activated Carbon in Drinking Water Treatment (정수처리에서 생물활성탄의 전처리로서 고급산화처리법의 평가)

  • Kim Woo-Hang
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.725-730
    • /
    • 1999
  • The advanced oxidation process (AOP) using ozone combined with hydrogen peroxide and ultraviolet treatment were evaluated for biodegradable dissolved organic carbon (EDOC) formation and dissolved organic carbon (DOC) removal. Oxidation treatment were conducted alone or combination with ozone, hydrogen peroxide and ultraviolet processes. Ozone dosage of ozone process was varied from $0.5mg/l{\ell}\cdot}min$ to $5mg/{\ell}{\cdot}min$. Ozone/hydrogen peroxide process was done using $20mg/{\ell}{\cdot}min$ of hydrogen peroxide concentration. Ozone/ultraviolet process was irradiated with $12mW/cm^2$ of density and 254nm. Ozone dosage was varied from $0.5mg/{\ell}{\cdot}min$ to $5mg/{\ell}{\cdot}min$ at the ozone/hydrogen peroxide and ozone/ultraviolet processes too. Contact time of all the process was 20 minutes. Oxidation treatment were performed on microfiltration effluent samples. BDOC formation was reached to an optimum at ozone dosage of $1.5mg/{\ell}{\cdot}min$ in the ozone/hydrogen peroxide process and $1mg/{\ell}{\cdot}min$ in ozone/ultraviolet process, after which BDOC formation was decreased at higher ozone dosages. But BDOC formation was increased with ozone dosages increasing in ozone process. The efficiency of DOC removal was higher AOPs than ozone process. Ozone/ultraviolet proces was the highest for DOC removal efficiency in each process. THMFP. removal efficiency by ozone/ultraviolet process was higher than that by each of ozone process and ozone/hydrogen peroxide process.

  • PDF

Proposal of enhanced treatment process based on actual pilot plant for removal of micropharmaceuticals in sewage treatment plants

  • Lee, Shun-hwa;Park, Yun-kyung;Lee, Miran;Lee, Byung-dae
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.588-596
    • /
    • 2020
  • This study was carried out to increase the treatment efficiency through the improvement of the conventional biological process, and to propose the optimal treatment direction. The optimal treatment conditions were derived based on the results of the spike damage tests in each single process. The removal efficiency of micropharmaceuticals was further increased when an ozone treatment process was added to the biological process compared to the single process. The soil and activated carbon adsorption process was introduced in the post-treatment to remove the micropharmaceutical residues, and the removal efficiency of the pharmaceduticals in the final effluent was more than 85% in spike damage experiment. In particular, the continuous process of biological treatment-ozone-adsorption could ensure the stable treatment of micropharmaceuticals, which had not been efficiently removed in the single process, as it showed more than 80% removal efficiency. Therefore, it is expected that the addition of the ozone oxidation and activated carbon adsorption process to the existing sewage treatment facilities can contribute to the efficient removal of micropharmaceuticals.

Cost Evaluation for the Decision of Advanced Treatment Processes (최적 고도정수처리공정 선정을 위한 경제성 평가)

  • Lee, Kyung-Hyuk;Shin, Heung-Sup;An, Hyo-Won;Chae, Sun-Ha;Lim, Jae-Lim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.511-516
    • /
    • 2008
  • Since 1989, Advanced drinking water treatment processes began to build in Korea, especially the water treatment plants around the Nak-dong river stream due to sequential pollutant accidents. Moreover, Advanced drinking water treatment processes, ozone and GAC, are again to be built in water treatment plants around Han-river stream to control taste and odor, micro pollutants. However, there are still a lot of discussion to decide the processes to apply for advanced treatment. Thus there are still need to understand clearly on the cost evaluation of each advanced treatment processes. The cost evaluation was accomplished based on the data of six water treatment plants which are currently being either operating or constructing. Exceptionally, PAC(Powdered Activated Carbon) process was evaluated with cost estimation from construction company. The capital cost per unit volume of ozone process was significantly decreased as the treatment capacity increased. The capital cost was in the order of GAC, ozone and GAC. The operation cost decreased in the order of PAC, GAC and ozone. The total cost considering present value shows that ozone process covers 84% of ozone and GAC process for $30,000m^3/d$ capacity while it covers less than 35% for over 140 thousands $m^3/d$ capacity. Comparing GAC only, and ozone/GAC process, ozone/GAC process is more cost effective for high capacity water treatment plant.

Removal Characteristics of Dichloroacetic Acid at Different Catalyst Media with Advanced Oxidation Process Using Ozone/Catalyst (담지체를 달리한 오존/촉매 AOP공정에서 디클로로아세트산의 제거 특성)

  • Park, Jin Do;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.87-93
    • /
    • 2009
  • Pd/activated carbon (Pd/AC) and Pd/alumina (Pd/AO) catalysts were prepared by the impregnation of palladium into activated carbon and alumina. The catalytic characteristics according to the kinds of support materials were compared. The decomposition efficiencies of ozone according to kinds of support materials are about the same when these were compared by adding 10 g of catalysts into the water saturated with ozone. The decomposition efficiencies and the oxidation characteristics (TOC, $COD_{Cr}$) of dichloroacetic acid were compared with the ozone only process and the catalytic ozonations using Pd/activated carbon and Pd/alumina catalysts. The decomposition efficiencies of dichloroacetic acid by catalytic ozonations were better than the one by ozone only process, but there was slight difference of the one between Pd/activated carbon and Pd/alumina catalyst. The decomposition efficiency of dichloroacetic acid was increased with increasing ozone dose at a constant concentration of dichloroacetic acid, but the one was little increased with increasing ozone dose at more than 1.0 L/min of ozone dose. It was seemed that the bicarbonate and the chloric ion formed throughout the decomposition of dichloroacetic acid acted as the scavenger of hydroxyl radical.

Effect of Reactivation of Activated Carbon on Adsorption of Natural Organic Matter (활성탄 재생이 자연유기물질의 흡착에 미치는 영향)

  • Hong, Seongho;Choi, Jusol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.323-329
    • /
    • 2007
  • There is no certain definition about advanced drinking water treatment but it is generally known as activated carbon process, membrane process or ozone process which can remove non-conventional pollutants such as taste and odor compounds, and micro-pollutants. There are more than 20 processes related to activated carbon as adsorber or biological activated carbon in Korea. The saturated carbon by pollutants can be reused by reactivation. However, the effect of reactivation on activated carbon is not well-understood in terms of changing physical properties of carbon to adsorption capacity of natural organic matter (NOM). In this study, the effects of reactivation on physical properties of activated carbon were investigated by isotherm and breakthrough of NOM. Ash content was increased from 8% to 13.3%. Iodine number is commonly used as an indicator for performance of reactivation. The iodine number was decreased about 20% after reactivating twice. The degree of reactivation can be evaluated by not only iodine number but also apparent density.

Removal Characteristics of Phenol at Advanced Oxidation Process with Ozone/Activated Carbon Impregnated Metals (오존/촉매 산화공정에서 금속담지 활성탄을 이용한 페놀의 분해 특성)

  • Choi, Jae Won;Yoon, Ji Young;Park, Jin Do;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.302-307
    • /
    • 2012
  • Advanced oxidation processes (AOP) such as O3/activated carbon process and O3/catalysts process were used to compare the decomposition of phenol. Catalysts such as Pd/activated carbon (Pd/AC), Mn/activated carbon (Mn/AC), Co/activated carbon (Co/AC) and Fe/activated carbon (Fe/AC) were prepared by impregnation of Pd, Mn, Co and Fe into the activated carbon of pellet form, respectively. Based on an hour of reactions, the following descending order for the decomposition ratios of dissolved O3 to the 1.48 mg/L of saturated dissolved O3 was observed: Mn/AC (45%) > Pd/AC (42%) > Co/AC (33%) > AC (31%) > Fe/AC (27%). The removal efficiencies of phenol were also arranged in the descending order of AOP as follows: Mn/AC (89%) > Pd/AC (85%) > Co/AC (77%) > AC (76%) > Fe/AC (71%). The remaining ratios (C/Co) of TOC (total organic carbon) after an hour of experiments were arranged in the ascending order of AOP as follows : Pd/AC (0.29) < Mn/AC (0.36) < AC (0.40) < Co/AC (0.49) < Fe/AC (0.51). However, the catalytic effects in the Co/AC and the Fe/AC processes were little in comparison with O3/AC process. The maximum concentrations of intermediates such as hydroquinone and catechol formed from the decomposition of phenol were arranged in the ascending order of AOP as follows: Pd/AC < Fe/AC < Co/AC < AC < Mn/AC. In the case of Pd/AC process, these intermediates were almost disappeared after an one hour of reaction.

A Study on Removal of Phenol and Its By-Product by Ozone, Ozone/Hydrogen Peroxide and Ozone/Granular Activated Carbon (오존, 오존/과산화수소와 오존/활성탄 처리에 의한 페놀 및 그 부산물의 제거에 관한 연구)

  • 배현주;김영규;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.121-129
    • /
    • 1997
  • This study was performed to delineate the removal phenol in solutions using of ozone, ozone/$H_2O_2$ and ozone/GAC. The disinfection by-product of phenol by ozonation, hydroquinone, was analyzed and it's control process was investigated. The followings are the conclusions that were derived from this study. 1. The removal efficiency of phenol by ozonation was 58.37%, 48.34%, 42.15%, and 35.41% which the initial concentration of phenol was 5 mg/l, 10 mg/l, 15 mg/l, and 20 mg/l, respectively. 2. The removal efficiency of phenol by ozonation was 42.95% at pH 4.0 and 69.39% at pH 10, respectively. The removal efficiencies were gradually increased, as pH values were increased. 3. With the ozone/$H_2O_2$ combined system, the removal efficiency of phenol was 72.87%. It showed a more complete degradation of phenol with ozone/$H_2O_2$ compared with ozone alone. 4. When ozonation was followed by filtration on GAC, phenol was completely removed. 5. Oxidation, if carried to completion, truly destroys the organic compounds, converting them to carbon dioxide. Unless reaction completely processed, disinfection by-products would be produced. To remove them, ozone/GAC treatment was used. The results showed that disinfection by-product of phenol by ozonation, hydroquinone, was completely removed. These results suggested that ozone/GAC should also be an appropriate way to remove phenol and its by-product.

  • PDF