Browse > Article

Cost Evaluation for the Decision of Advanced Treatment Processes  

Lee, Kyung-Hyuk (한국수자원공사 수자원연구원)
Shin, Heung-Sup (한국종합엔지니어링)
An, Hyo-Won (한국수자원공사 수도권건설단)
Chae, Sun-Ha (한국수자원공사 수자원연구원)
Lim, Jae-Lim (한국수자원공사 수자원연구원)
Publication Information
Journal of Korean Society of Water and Wastewater / v.22, no.5, 2008 , pp. 511-516 More about this Journal
Abstract
Since 1989, Advanced drinking water treatment processes began to build in Korea, especially the water treatment plants around the Nak-dong river stream due to sequential pollutant accidents. Moreover, Advanced drinking water treatment processes, ozone and GAC, are again to be built in water treatment plants around Han-river stream to control taste and odor, micro pollutants. However, there are still a lot of discussion to decide the processes to apply for advanced treatment. Thus there are still need to understand clearly on the cost evaluation of each advanced treatment processes. The cost evaluation was accomplished based on the data of six water treatment plants which are currently being either operating or constructing. Exceptionally, PAC(Powdered Activated Carbon) process was evaluated with cost estimation from construction company. The capital cost per unit volume of ozone process was significantly decreased as the treatment capacity increased. The capital cost was in the order of GAC, ozone and GAC. The operation cost decreased in the order of PAC, GAC and ozone. The total cost considering present value shows that ozone process covers 84% of ozone and GAC process for $30,000m^3/d$ capacity while it covers less than 35% for over 140 thousands $m^3/d$ capacity. Comparing GAC only, and ozone/GAC process, ozone/GAC process is more cost effective for high capacity water treatment plant.
Keywords
PAC(Powdered Activated Carbon); Ozone; GAC(Granular Activated Carbon); Cost Analysis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 서울특별시 상수도연구원(2007) 서울시 고도정수처리 3단계 보고서, pp. 156-157.
2 윤제용(2003) 서울시 정수장 고도 정수 처리 시설 도입 필요성 검토, 한국수처리기술연구학회지, 1권 2호 pp. 23-24.
3 윤제용, 손진식, 최승일, 문성민 (2005) 국내 정수장 고도정수시설의 설계 및 운영상의 문제점과 제언, 상하수도학회지, 19권 3호 pp. 268-276.