• Title/Summary/Keyword: oxygen

Search Result 15,888, Processing Time 0.044 seconds

Effect of oxygen working pressure on morphology and luminescence properties of SnO2 micro/nanocrystals formed by thermal evaporation method

  • Kim, Min-Sung
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.5
    • /
    • pp.424-427
    • /
    • 2018
  • The effect of oxygen pressure in the synthesis of $SnO_2$ micro/nanocrystals through thermal evaporation of Sn powder was investigated. The thermal evaporation process was performed at $1000^{\circ}C$ for 1 hr under various oxygen pressures. The pressure of oxygen changed from 10 to 500 Torr. The morphology of $SnO_2$ crystals changed drastically with oxygen pressure. $SnO_2$ nanoparticles with an average diameter of 120 nm were formed at oxygen pressure lower than 10 Torr. $SnO_2$ nanowires were grown under an oxygen pressure of 100 Torr. The nanowires have diameters in the range of 100 ~ 500 nm and lengths of several tens of micrometers. As increasing the oxygen pressure to 500 Torr, the sizes of wires increased. A strong visible emission peak centered at about 500 ~ 600 nm was observed in the room temperature cathodoluminescence spectra of all the products.

Estimation of Oxygen Consumption Rates by Using an Oxygen Microelectrode in Ganghwa Intertidal Flat (강화도 남부 갯벌퇴적물에서 산소 미세전극을 이용한 산소소모율 추정)

  • Kim, Dong-Seon
    • Ocean and Polar Research
    • /
    • v.28 no.2
    • /
    • pp.119-127
    • /
    • 2006
  • We measured oxygen microprofiles using an oxygen microelectrode in Ganghwa intertidal flat in April and September. Oxygen consumption rate was calculated by using three different methods based on the oxygen microprofiles. The method using the PROFILE software was thought to be the most reliable among the three methods. The oxygen consumption rates calculated at station D1 by using the PROFILE software were 10.5 and 6.27mmol $m^{-2}d^{-1}$ in April and September, respectively. At station D2, they were 10.9mmol $m^{-2}d^{-1}$ in April and 5.39 mmol $m^{-2}d^{-1}$ in September. There was little spatial variation, but large seasonal variation, with almost two times larger values in April than in September. The higher rate in April is ascribed to higher oxygen concentration in the seawater and higher organic carbon content in the surface sediments, which probably accelerate oxygen consumption for organic matter decomposition in the sediments. Aerobic remineralization rates estimated from the oxygen consumption rates ranged from 4.14 to 8.07 mmol C $m^{-2}d^{-1}$ in Ganghwa intertidal flat, which were much lower than the anaerobic remineralization rate.

Oxygen detection of sensor cells based on YSZ (Yttria-Stabilized Zirconia) thin films (YSZ(yttria-stabilized zirconia) 박막을 이용한 센서 셀의 산소 감응)

  • 박준용;배정운;황순원;김기동;조영아;전진석;최동수;염근영
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.507-513
    • /
    • 1999
  • 8mol%-yttria-stabilized zirconia(YSZ) thin films as oxygen ion conductor were deposited by rf-magnetron sputtering, and the oxygen gas sensors with the structure of $SiO_2$ substrate/Ni-NiO mixed reference layer/Pt/YSZ/Pt were fabricated and their oxygen sensing properties were investigated. The steady-state electro-motive force (EMF) values were measured as a function of oxygen partial pressure ($PO_2;form 1.013\times10^3 \textrm{Pa \;to}\; 1.013\times10^5$Pa) and operating temperature ($300^{\circ}C$ to $700^{\circ}C$). The fabricated YSZ oxygen sensor showed the best oxygen sensing properties at 50$0^{\circ}C$. However, oxygen sensing properties were very low at the temperature lower than 30$0^{\circ}C$ due to the lack of oxygen ion mobility and at the temperature higher than $700^{\circ}C$ due 새 intermixing of materials between the layers. Especially, the YSZ sensor operating at $500^{\circ}C$ and oxygen partial pressure above $1.565\times10^4$Pa showed the oxygen sensing properties close to the values predicted by ideal Nernst equation.

  • PDF

Effective Oxygen-Defect Passivation in ZnO Thin Films Prepared by Atomic Layer Deposition Using Hydrogen Peroxide

  • Wang, Yue;Kang, Kyung-Mun;Kim, Minjae;Park, Hyung-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.3
    • /
    • pp.302-307
    • /
    • 2019
  • The intrinsic oxygen-vacancy defects in ZnO have prevented the preparation of p-type ZnO with high carrier concentration. Therefore, in this work, the effect of the concentration of H2O2 (used as an oxygen source) on the oxygen-vacancy concentration in ZnO prepared by atomic layer deposition was investigated. The results indicated that the oxygen-vacancy concentration in the ZnO film decreased by the oxygen-rich growth conditions when using H2O2 as the oxygen precursor instead of a conventional oxygen source such as H2O. The suppression of oxygen vacancies decreased the carrier concentration and increased the resistivity. Moreover, the growth orientation changed to the (002) plane, from the combined (100) and (002) planes, with the increase in H2O2 concentration. The passivation of oxygen-vacancy defects in ZnO can contribute to the preparation of p-type ZnO.

Experimental Study on the Oxygen Combustion Characteristics with $CO_2$ Feeding ($CO_2$ 첨가에 따른 순산소 연소기의 연소특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Guahk, Young-Tae;Bae, Soo-Ho;Hong, Jung-Goo;Lee, Uen-Do;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.26-34
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below $\lambda=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF

Experimental Study on the Effect of $CO_2$ Feeding on the Oxygen Combustion Characteristics by using Inverse Type Multi-hole Burner (역확산 다공 연소기에서 $CO_2$ 첨가에 따른 순산소 연소 특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Guahk, Young-Tae;Bae, Soo-Ho;Hong, Jung-Goo;Lee, Uen-Do;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.162-169
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below ${\lamda}=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF

Design of 3-Sectored Oxygen Chamber with Automatic Control Function based on Embedded System (임베디드시스템 기반 자동제어 기능의 삼단분리형 산소챔버 설계)

  • Cho, Myeon-gyun
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.3
    • /
    • pp.71-77
    • /
    • 2018
  • In this paper, considering the oxygen sensitivity and preference pattern of the patient, the profile of the oxygen therapy of the individual is specified. And, we design a three-compartment, single compartment oxygen chamber that automatically adjusts the oxygen pressure according to the specified profile. Hyperbaric oxygen therapy is a method of providing patients with 100% oxygen higher than atmospheric pressure for therapeutic purposes. However, there is a disadvantage that the ear pain is caused by the pressure difference depending on the individual. Based on the embedded system, the proposed system creates a patient-tailored oxygen therapy profile by DB of patient's preference patterns and treatment records of oxygen therapy. If only the patient's name is entered, the oxygen chamber system can adjust the oxygen pressure automatically according to the profile pattern to maximize the oxygen treatment effect.

Performance Comparison of Spray-dried Mn-based Oxygen Carriers Prepared with γ-Al2O3, α-Al2O3, and MgAl2O4 as Raw Support Materials

  • Baek, Jeom-In;Kim, Ui-Sik;Jo, Hyungeun;Eom, Tae Hyoung;Lee, Joong Beom;Ryu, Ho-Jung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.285-291
    • /
    • 2016
  • In chemical-looping combustion, pure oxygen is transferred to fuel by solid particles called as oxygen carrier. Chemical-looping combustion process usually utilizes a circulating fluidized-bed process for fuel combustion and regeneration of the reduced oxygen carrier. The performance of an oxygen carrier varies with the active metal oxide and the raw support materials used. In this work, spraydried Mn-based oxygen carriers were prepared with different raw support materials and their physical properties and oxygen transfer performance were investigated to determine that the raw support materials used are suitable for spray-dried manganese oxide oxygen carrier. Oxygen carriers composed of 70 wt% $Mn_3O_4$ and 30 wt% support were produced using spray dryer. Two different types of $Al_2O_3$, ${\gamma}-Al_2O_3$ and ${\alpha}-Al_2O_3$, and $MgAl_2O_4$ were applied as starting raw support materials. The oxygen carrier prepared from ${\gamma}-Al_2O_3$ showed high mechanical strength stronger than commercial fluidization catalytic cracking catalyst at calcination temperatures below $1100^{\circ}C$, while the ones prepared from ${\alpha}-Al_2O_3$ and $MgAl_2O_4$ required higher calcination temperatures. Oxygen transfer capacity of the oxygen carrier prepared from ${\gamma}-Al_2O_3$ was less than 3 wt%. In comparison, oxygen carriers prepared from ${\alpha}-Al_2O_3$ and $MgAl_2O_4$ showed higher oxygen transfer capacity, around 3.4 and 4.4 wt%, respectively. Among the prepared Mn-based oxygen carriers, the one made from $MgAl_2O_4$ showed superior oxygen transfer performance in the chemical-looping combustion of $CH_4$, $H_2$, and CO. However, it required a high calcination temperature of $1400^{\circ}C$ to obtain strong mechnical strength. Therefore, further study to develop new support compositions is required to lower the calcination temperature without decline in the oxygen transfer performance.

Molecular Beam Epitaxial Growth of Oxide Single Crystal Films

  • Yoon, Dae-Ho;Yoshizawa, Masahito
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.508-508
    • /
    • 1996
  • ;The growth of films have considerable interest in the field of superlattice structured multi-layer epitaxy led to realization of new devices concepts. Molecular beam epitaxy (MBE) with in situ observation by reflection high-energy electron diffraction (RHEED) is a key technology for controlled layered growth on the atomic scale in oxide crystal thin films. Also, the combination of radical oxygen source and MBE will certainly accelerate the progress of applications of oxides. In this study, the growth process of single crystal films using by MBE method is discussed taking the oxide materials of Bi-Sr-Ca-Cu family. Oxidation was provided by a flux density of activated oxygen (oxygen radicals) from an rf-excited discharge. Generation of oxygen radicals is obtained in a specially designed radical sources with different types (coil and electrode types). Molecular oxygen was introduced into a quartz tube through a variable leak valve with mass flowmeter. Corresponding to the oxygen flow rate, the pressure of the system ranged from $1{\;}{\times}{\;}10^{-6}{\;}Torr{\;}to{\;}5{\;}{\times}{\;}10^{-5}$ Torr. The base pressure was $1{\;}{\times}{\;}10^{-10}$ Torr. The growth of Bi-oxides was achieved by coevaporation of metal elements and oxygen. In this way a Bi-oxide multilayer structure was prepared on a basal-plane MgO or $SrTiO_3$ substrate. The grown films compiled using RHEED patterns during and after the growth. Futher, the exact observation of oxygen radicals with MBE is an important technology for a approach of growth conditions on stoichiometry and perfection on the atomic scale in oxide. The oxidization degree, which is determined and controlled by the number of activated oxygen when using radical sources of two types, are utilized by voltage locked loop (VLL) method. Coil type is suitable for oxygen radical source than electrode type. The relationship between the flux of oxygen radical and the rf power or oxygen partial pressure estimated. The flux of radicals increases as the rf power increases, and indicates to the frequency change having the the value of about $2{\times}10^{14}{\;}atoms{\;}{\cdots}{\;}cm^{-2}{\;}{\cdots}{\;}S^{-I}$ when the oxygen flow rate of 2.0 seem and rf power 150 W.150 W.

  • PDF

Evaluation of Energy Cost in Terms of Oxygen Uptake by Measuring Heart Rate During Tennis Games (심박수에 의한 테니스경기의 에너지 소요량 측정)

  • Cho, Byung-Hee;Chung, Kyou-Chull;Hong, Yeon-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.289-294
    • /
    • 1984
  • The energy expended while playing tennis was determined from the players heart rate and from the amount of oxygen they consumed. This study was made using eight healthy but unathletic male college students. Expired air was collected for 2 minute periods during each game by the Douglas bag method. Samples were collected when serving and receiving. The air collected was measured using a wet test gas meter. The amount of air collected was expressed in STPD. Oxygen consumption was determined by measuring the oxygen content of the expired air with a Orzat gas analyzer. The energy expended during the tennis games was calculated indirectly. The caloric coefficient of oxygen was multiplied by the volume of oxygen consumed. The caloric coefficient of oxygen varied from 4.6 to 5.1 kcal/liter of oxygen. In this study the value of 5 kcal/liter of oxygen was used in the calculations. The accuracy of the measurements of energy expended was tested using regression analysis of the measured volume of oxygen. The mean values of heart rate, oxygen consumed and energy expended did not vary when the activity of serving and receiving was compared. The mean value of oxygen consumed during play was $1.4329{\pm}282ml/min$ or $21.6{\pm}4.0ml/kg/min$. The energy expended was $7.15{\pm}1.46kcal/min$ or $6.45{\pm}1.23kcal/kg/min$. The values were equivalent to 5.5 mets. When the levels of oxygen consumed were estimated using the formulas, they were found to be higher than the measured levels. The estimated amounts, however, were within 25% of the measured amounts.

  • PDF