• Title/Summary/Keyword: oxidation layer

Search Result 1,137, Processing Time 0.028 seconds

Thermal and Mechanical Evaluation of Environmental Barrier Coatings for SiCf-SiC Composites (SiCf-SiC 복합재료의 내환경 코팅 및 열, 기계적 내구성 평가)

  • Chae, Yeon-Hwa;Moon, Heung Soo;Kim, Seyoung;Woo, Sang Kuk;Park, Ji-Yeon;Lee, Kee Sung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.84-93
    • /
    • 2017
  • This study investigates thermal and mechanical characterization of environmental barrier coating on the $SiC_f-SiC$ composites. The spherical environmental barrier coating (EBC) powders are prepared using a spray drying process for flowing easily during coating process. The powders consisting of mullite and 12 wt% of Ytterbium silicate are air plasma sprayed on the Si bondcoat on the LSI SiC fiber reinforced SiC composite substrate for protecting the composites from oxidation and water vapor reaction. We vary the process parameter of spray distance during air plasma spray of powders, 100, 120 and 140 mm. After that, we performed the thermal durability tests by thermal annealing test at $1100^{\circ}C$ for 100hr and thermal shock test from $1200^{\circ}C$ for 3000 cycles. As a result, the interface delamination of EBC never occur during thermal durability tests while stable cracks are prominent on the coating layer. The crack density and crack length depend on the spray distance during coating. The post indentation test indicates thermal tests influence on the indentation load-displacement mechanical behavior.

Development of Immuno-Analytical System for Microbial Cells by using Dot-Blotter (Dot-Blotter 진공 포획방식에 의한 미생물세포 면역분석시스템의 개발)

  • 목락선;하연철;윤희주;백세환
    • KSBB Journal
    • /
    • v.14 no.1
    • /
    • pp.82-90
    • /
    • 1999
  • In order to eventually fabricate an analytical system for infectious microorganisms, we synthesized major immunochemical components, utilized them for the construction of model system, and investigated an assay concept for bacterial whole cells. For the preparation of system components, a polyclonal antibody, against Salmonella thompson as model analyte, purified by immuno-affinity chromatography was used to chemically link to streptavidin or an enzyme, horseradish peroxidase(HRP). The antibody and streptavidin was modified with sulfosuccinimidyl 4-[N-maleimidomethyl]cyclohexane-1-carboxylate and N-succinimidyl-3-[2-pyridyldithio]propionate(subsequently activated by dithiotheritol), respectively. The modified components were reacted to synthesize antibody-streptavidin conjugates which were then purified on a two-layer chromatography column of diaminobiotin gel and Sephadex G-100. For antibody-HRP conjugates, HRP molecules were activated by $NalO_4$ oxidation and then coupled to immunoglobulin. After stabilizing with ($NaCNBH_3$, the conjugates were purified by size exclusion chromatography on Biogel A5M column. To devise a model system, such produced components were combined with a dot-blotter in which a nitrocellulose membrane($12{\mu}m$ pre size) with immobilized biotin was already located. The analyte (S. thompson cells) was reacted with the both antibody conjugates in a liquid phase, and the complexes formed were captured on the membrane surfaces by applying vacuum in the bottom compartment of the blotter to invoke biotin-streptavidin reaction. Under optimal conditions, the system enabled to identify the analytical concept for bacterial whole cells, and the lower limit of detection was approximately $1{\mu}g/m{\ell}$($10^5-10^6$ cells/m$m{\ell}$). The controlling factors were the concentrations of each antibody conjugate that caused agglutination in the presence of analyte as they increased.

  • PDF

Morphology of RF-sputtered Mn-Coatings for Ti-29Nb-xHf Alloys after Micro-Pore Form by PEO

  • Park, Min-Gyu;Park, Seon-Yeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.197-197
    • /
    • 2016
  • Commercially pure titanium (CP Ti) and Ti-6Al-4V alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Manganese(Mn) plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Radio frequency(RF) magnetron sputtering in the various PVD methods has high deposition rates, high-purity films, extremely high adhesion of films, and excellent uniform layers for depositing a wide range of materials, including metals, alloys and ceramics like a hydroxyapatite. The aim of this study is to research the Mn coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. Mn coatings was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Mn coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Electrochemical Characteristics of Zn and Si Ion-doped HA Films on Ti-6Al-4V by PEO Treatment

  • Lim, Sang-Gyu;Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.199-199
    • /
    • 2016
  • Commercially pure titanium (cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Electrochemical deposition method is an attractive technique for the deposition of hydroxyapatite (HAp). However, the adhesions of these coatings to the Ti surface needs to be improved for clinical used. Plasma electrolyte oxidation (PEO) enables control in the chemical com position, porous structure, and thickness of the $TiO_2$ layer on Ti surface. In addition, previous studies h ave concluded that the presence of $Ca^{+2}$ and ${PO_4}^{3-}$ ion coating on porous $TiO_2$ surface induced adhesion strength between HAp and Ti surface during electrochemical deposition. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study electrochemical characteristcs of Zn and Si coating on Ti-6Al-4V by PEO treatment. The coating process involves two steps: 1) formation of porous $TiO_2$ on Ti-6Al-4V at high potential. A pulsed DC power supply was employed. 2) Electrochemical tests were carried out using potentiodynamic and AC impedance methoeds. The morphology, the chemical composition, and the micro-structure an alysis of the sample were examined using FE-SEM, EDS, and XRD. The enhancements of the HAp forming ability arise from $Si/Zn-TiO_2$ surface, which has formed the reduction of the Si/Zn ions. The promising results successfully demonstrate the immense potential of $Si/Zn-TiO_2$ coatings in dental and biomaterials applications.

  • PDF

Vitis amurensis Ruprecht root inhibited ${\alpha}$-melanocyte stimulating hormone-induced melanogenesis in B16F10 cells

  • Jin, Kyong-Suk;Oh, You Na;Hyun, Sook Kyung;Kwon, Hyun Ju;Kim, Byung Woo
    • Nutrition Research and Practice
    • /
    • v.8 no.5
    • /
    • pp.509-515
    • /
    • 2014
  • BACKGROUND/OBJECTIVES: The root of Vitis amurensis Ruprecht, a sort of wild-growing grape, has been used in oriental medicine for treatment of skin ailments; however, its dermatological activity is not sufficiently understood. The aim of this study was to investigate tyrosinase inhibitory and anti-melanogenic activities of V. amurensis Ruprecht root methanol extract (VARM) in B16F10 mouse melanoma cells and to attempt to isolate and identify the active compound issued from VARM. MATERIALS/METHODS: Anti-melanogenic activity of VARM was analyzed in ${\alpha}$-melanocyte stimulating hormone (MSH)-stimulated B16F10 cells through evaluation of antioxidative activity as well as inhibited tyrosinase activity and melanin contents compared with those of kojic acid and arbutin. After anti-melanogenic analysis of VARM, serial fractionation, nuclear magnetic resonance (NMR), and thin layer chromatorgraphy (TLC) were applied for identification of active compounds contained in VARM. RESULTS: VARM significantly inhibited oxidative stress and tyrosinase activity and attenuated ${\alpha}$-MSH-induced melanin production in B16F10 cells. For isolation of active compounds, VARM was fractionated using a series of organic solvents, including dichloromethane ($CH_2Cl_2$), ethyl acetate (EtOAc), and n-butanol (n-BuOH). Among fractions showing anti-melanogenic activity, the CH2Cl2 fraction induced the most potent attenuation of melanogenesis without cytotoxicity and the major compound in the $CH_2Cl_2$ fraction was identified as betulinic acid. Betulinic acid isolated from the $CH_2Cl_2$ fraction of VARM significantly attenuated ${\alpha}$-MSH-induced melanogenesis in a dose dependent manner, which was stronger than that of arbutin used as a positive control. CONCLUSIONS: These results indicate that VARM inhibits oxidative stress, tyrosinase activity, and ${\alpha}$-MSH-induced melanogenesis in B16F10 cells, due primarily to the active compound, betulinic acid, in the $CH_2Cl_2$ fraction.

A Study on Improvement of Durability for Run-out Table Roller with Hot Rolling by Porous Self-fluxing Alloy Coating (다공질 자용성 합금 피복에 의한 열간 압연용 런-아웃 테이블 롤러의 내구성 향상에 관한 연구)

  • Bae, Myung-Whan;Park, Byoung-Ho;Jung, Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.276-285
    • /
    • 2012
  • The objective of this research is to develop the coating technique by a porous self-fluxing alloy for improving the mechanical properties of run-out table roller surface with the hot rolling. To enhance the durability of run-out table roller with the hot rolling, the high hardness of roller surface should be maintained at high temperatures, and the improvement of wear resistance, corrosion resistance, heat resistance, burn resistance and adhesion resistance should be maintained. In order to be able to transport reliably a hot rolled steel sheet, also, the appropriate friction coefficient on the roller surface should be maintained and the slip between roller and steel should not occur. In this study, the wear resistance of roller increases after the self-fluxing alloy is changed to a cermet by adding the tungsten carbide(WC), and the coefficient of friction increases and the ability of grip is improved because the porosities are made by coating with fine iron powder on the roller surface. As a result, it is found that the ability of grip between the steel and the roller coated by a porous self-fluxing alloy contained to 5 ~ 10 wt% of Fe in the coating layer is improved compared to the roller coated by Ni-Cr. This is because the porosities are made after Fe contained in the roller is partially alloyed by heating with a furnace in the fusing process and the rest is eliminated by oxidation and dissolution.

A Field Research on Mud Flat Remediation by Biological Treatments (생물학적 처리에 따른 갯벌 복원을 위한 현장 적용성 연구)

  • Cho, Dae-Chul;Bae, Hwan-Jin;Kwon, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3285-3294
    • /
    • 2012
  • A field test on mud flat remediation was carried out in order to observe the effects of the treatments such as microbial dose and an oxygen releasing compound like $CaO_2$. The size of each treatment site was $100m^2$ and the dosage was 3.6 kg per site. The 6 week monitoring showed that pH on two sites was below 7 and ORP increased from .178~-188 mV to .121~-142 mV. In Ignition loss and COD there were no significant changes. Meanwhile nitrogen and phosphorus concentrations changed: ammonia concentration decreased both on control and treatment sites. Nitrate nitrogen decreased more on combined treatment site than on single microbial treatment (11.3% vs. 7.3%) probably because the extra oxygen supplied by $CaO_2$ formed more oxic environment so that the facilitated nitrification might produce more nitrate but the nitrate would be much rapidly released into the water layer out of the sediment. That also explains the total nitrogen reduction(6.1%). Similarly, T-P and $PO_4-P$ reduced by 29% and 31.8%, respectively on combined treatment sites, resulting from the phosphorus release effect though the initial concentrations of the two factors were considerably high.

Microfabrication of submicron-size hole for potential held emission and near field optical sensor applications (전계방출 및 근접 광센서 응용을 위한 서브 마이크론 aperture의 제작)

  • Lee, J.W.;Park, S.S.;Kim, J.W.;M.Y. Jung;Kim, D.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.2
    • /
    • pp.99-101
    • /
    • 2000
  • The fabrication of the submicron size hole has been interesting due to the potential application of the near field optical sensor or liquid metal ion source. The 2 micron size dot array was photolithographically patterned. After formation of the V-groove shape by anisotropic KOH etching, dry oxidation at $1000^{\circ}C$ for 600 minutes was followed. In this procedure, the orientation dependent oxide growth was performed to have an etch-mask for dry etching. The reactive ion etching by the inductively coupled plasma (ICP) system was performed in order to etch ~90 nm $SiO_2$ layer at the bottom of the V-groove and to etch the Si at the bottom. The negative ion energy would enhance the anisotropic etching by the $Cl_2$ gas. After etching, the remaining thickness of the oxide on the Si(111) surface was measured to be ~130 nm by scanning electron microscopy. The etched Si aperture can be used for NSOM sensor.

  • PDF

Effect of Titanium Addition on Indium Zinc Oxide Thin Film Transistors by RF-magnetron Sputtering (RF-magnetron sputtering을 이용한 TiIZO 기반의 산화물 반도체에 대한 연구)

  • Woo, Sanghyun;Lim, Yooseong;Yi, Moonsuk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.115-121
    • /
    • 2013
  • We fabricated thin film transistors (TFTs) using TiInZnO(TiIZO) thin films as active channel layer. The thin films of TiIZO were deposited at room temperature by RF-magnetron co-sputtering system from InZnO(IZO) and Ti targets. We examined the effects of titanium addition by X-ray diffraction, X-ray photoelectron spectroscopy and the electrical characteristics of the TFTs. The TiIZO TFTs were investigated according to the radio-frequency power applied to the Ti target. We found that the transistor on-off currents were greatly influenced by the composition of titanium addition, which suppressed the formation of oxygen vacancies, because of the stronger oxidation tendency of Ti relative to that of Zn or In. A optimized TiIZO TFT with rf power 40W of Ti target showed good performance with an on/off current ratio greater than $10^5$, a field-effect mobility of 2.09 [$cm^2/V{\cdot}s$], a threshold voltage of 2.2 [V] and a subthreshold swing of 0.492 [V/dec.].

EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT (임플랜트 표면처리가 생체활성에 미치는 영향)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Yoon, Tae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.