• 제목/요약/키워드: oxidation current

검색결과 726건 처리시간 0.024초

Voltammetric Studies of Guanine and Its Derivatives by (TEX)$Ru(bpy)^{2+/3+}$(/TEX) Mediator on Indium Tin Oxide Electrode

  • 김진형
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권7호
    • /
    • pp.709-711
    • /
    • 2000
  • Oxidizing metal complex mediates the electrochemical oxidation of guanine nucleotides. This catalysis results in an enhancement in cyclic voltammograms that yield the rate constant for the oxidation of guanine by the metal complex via digital simulation. The rate constant of oxidation of guanine by Ru(bpy)3(3+) is 6.4 x 10(5)M(-1)s(-l). The rate constant and the enhanced current depend on the number of phosphate groups on the sugar of nucleotidc. Also the modified guanine bases show different oxidation rate constants following the trend guanine-5'- monophosphatc (GMP) > 8-bromo-guanine-5'-monophosphate (8-Br-GMP) > xanthosine -5'-monophosphate (XMP) > inosinc-5'-monophosphate (IMP). The guanine bases derivatized differently are all distinguishable from one another, providing a basis for studying electrochemistry of DNA and RNA and developing electrochemical biosensors.

수산전해액하에서 양극산화에 의한 무기 UF막의 제조 (Preparation of Inorganic Ultrafiltration Membrane by Anodic Oxidation in Oxalic Acid)

  • 이창우;홍영호;장윤호;함영민
    • 공업화학
    • /
    • 제9권4호
    • /
    • pp.536-541
    • /
    • 1998
  • 본 연구에서는 시판용 99.8% 금속알루미늄을 수산전해액에서 정전류 방식에 의하여 양극산화하여 다공성 알루미나 막을 제조하는 실험을 행하였다. 전기화학 반응은 표면반응으로 양극산화에 앞서 알루미늄판을 열산화, 화학연마 및 전해연마 등의 전처리를 행하였으며, 반응온도, 전기량, 수산전해질 농도 및 전류밀도의 변화에 따라 양극산화를 시행하여 형성된 다공성 알루미나 막의 세공크기와 분포, 세공밀도 및 막와 두께를 조사하였다. 양극산화에 의해 제조된 다공성 알루미나 막의 기하구조는 직선적인 원통형 세공을 가지며, 세공직경이 45~100 nm 범위로 세공분포가 매우 균일하고, 세공밀도가 $10{\sim}30{\times}10^8$개/$cm^2$로 우수한 세라믹막의 특성을 갖는 한외여과막을 제조할 수 있었다.

  • PDF

선택적 산화 방식을 이용한 핀 채널 MOSFET의 소스/드레인 저항 감소 기법 (Reduction of Source/Drain Series Resistance in Fin Channel MOSFETs Using Selective Oxidation Technique)

  • 조영균
    • 융합정보논문지
    • /
    • 제11권7호
    • /
    • pp.104-110
    • /
    • 2021
  • 본 핀 채널 전계 효과 트랜지스터에서 낮은 소스/드레인 직렬 저항을 위한 새로운 선택적 산화 방식을 제안하였다. 이 방법을 이용하면, gate-all-around 구조와 점진적으로 증가되는 형태의 소스/드레인 확장영역을 갖는 핀 채널 MOSFET를 얻을 수 있다. 제안된 트랜지스터는 비교 소자에 비해 70% 이상의 소스/드레인 직렬 저항의 감소를 얻을 수 있다. 또한, 제안된 소자는 단채널 효과를 억제하면서도 높은 구동 전류와 전달컨덕턴스 특징을 보인다. 제작된 소자의 포화전류, 최대 선형 전달컨덕턴스, 최대 포화 전달컨덕턴스, subthreshold swing, 및 DIBL은 각각 305 ㎂/㎛, 0.33 V, 13.5 𝜇S, 76.4 𝜇S, 78 mV/dec, 62 mV/V의 값을 갖는다.

Electrochemical treatment of cefalexin with Sb-doped SnO2 anode: Anode characterization and parameter effects

  • Ayse, Kurt;Hande, Helvacıoglu;Taner, Yonar
    • Advances in nano research
    • /
    • 제13권6호
    • /
    • pp.513-525
    • /
    • 2022
  • In this study, it was aimed to evaluate direct oxidation of aqueous solution containing cefalexin antibiotic with new generation Sn/Sb/Ni: 500/8/1 anode. The fact that there is no such a study on treatment of cefalexin with these new anode made this study unique. According to the operating parameters evaluation COD graphs showed clearer results compared to TOC and CLX and thus, it was it was chosen as major parameter. Furthermore, pseudo-first degree kd values were calculated from CLX results to show more accurate and specific results. Experimental results showed that after 60 min of electrochemical oxidation, complete removal of COD and TOC was accomplished with 750 mg L-1 KCl, at pH 7, 50 mA cm-2 current density and 1 cm anode-cathode distance. Also, the stability of the Sn/Sb/Ni anode was evaluated by taking SEM and AFM images and XRD analysis before and after of electrochemical oxidation processes. According to the results, it was not occurred too much change on the anode surface even after 300 h of electrolysis. Thus, it was thought that the anode material was not corroded to a large extent. Furthermore, the removal efficiencies were very high for almost all the time and conditions. According to the results of the study, electrochemical oxidation with new generation Sn/Sb/Ni anodes for the removal of cefalexin antibiotic was found very successful and applicable due to require less reaction time complete mineralization and doesn't require pH adjustment step compared to other studies in literature. In future studies, different antibiotic types should be studied with this anode and maybe with real wastewaters to test applicability of the process in treatment of pharmaceutical wastewaters containing antibiotics, in a better way.

Oxidative stability of omega-3 dietary supplements according to product characteristics

  • Kwon, Hyeon Jeong;Yun, Ho Cheol;Lee, Ji Yoon;Jeong, Eun Jung;Cho, Hyun Nho;Kim, Da Young;Park, Sung Ah;Lee, Seung Ju;Kang, Jung Mi
    • 분석과학
    • /
    • 제33권5호
    • /
    • pp.215-223
    • /
    • 2020
  • The objectives of the present study were to assess the oxidative stability of South Korean n-3 (omega-3 fatty acid) supplements carried out from 2018 to 2019 and evaluate the influence of product characteristics on oxidative safety. A total of 76 n-3 supplements were analysed for oxidation safety by four markers, including acid value (AV), primary oxidation (peroxide value, PV), secondary oxidation (p-anisidine value, pAV) and total oxidation value (TOTOX). Among the supplements tested, 5.3 %, 55.3 %, 28.9 % and 46.1 % exceeded the international voluntary recommended levels for AV, PV, pAV and TOTOX, respectively. Purity (%) of products, remainder of expiration date (suggested shelf life), package in press through package (PTP) and products with additives had statistically significant differences oxidation assessment levels (p < 0.05). In addition, n-3 group found in Algae oil had significantly lower AV levels than the group that did not, and product with Alaska pollack oil, had significantly higher pAV levels than without group (p < 0.05). The high oxidation status of South Korean n-3 products in the present study could not be considered a public health problem right now. However, the levels of oxidation may affect a lot the efficacy and safety of using n-3 supplements. Thus, current oxidation safety limits should be reestablished by regulatory bodies to ensure the safety and efficacy of n-3 supplements, so that the standards could be applied to the products available to consumers.

Fe(II)/과황산/전기화학적 산화 공정에 의한 2,4-D의 제거 (Removal of 2,4-D by an Fe(II)/persulfate/Electrochemical Oxidation Process)

  • 현영환;최지연;신원식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권1호
    • /
    • pp.45-53
    • /
    • 2021
  • The removal of 2,4-dichlorophenoxyacetic acid (2,4-D) in aqueous solution by coupled electro-oxidation and Fe(II) activated persulfate oxidation process was investigated. The electrochemical oxidation was performed using carbon sheet electrode and persulfate using Fe(II) ion as an activator. The oxidation efficiency was investigated by varying current density (2 - 10 mA/㎠), electrolyte (Na2SO4) concentration (10 - 100 mM), persulfate concentration (5 - 20 mM), and Fe(II) concentration (10 - 20 mM). The 2,4-D removal efficiency was in the order of Fe(II) activated persulfate-assisted electrochemical oxidation (Fe(II)/PS/ECO, 91%) > persulfate-electrochemical oxidation (PS/ECO, 51%) > electro-oxidation (EO, 36%). The persulfate can be activated by electron transfer in PS/ECO system, however, the addition of Fe(II) as an activator enhanced 2,4-D degradation in the Fe(II)/PS/ECO system. The 2,4-D removal efficiency was not affected by the initial pHs (3 - 9). The presence of anions (Cl- and HCO3-) inhibited the 2,4-D removal in Fe(II)/PS/ECO system due to scavenging of sulfate radical. Scavenger experiment using tert-butyl alcohol (TBA) and methanol (MeOH) confirmed that although both sulfate (SO4•-) and hydroxyl (•OH) radicals existed in Fe(II)/PS/ECO system, hydroxyl radical (SO4•-) was the predominant radical.

3D 복극충진전기분해를 이용한 원전 ETA에 의해 유발된 폐수 내 COD 및 T-N 제거 (Removal of COD and T-N caused by ETA from Nuclear Power Plant Wastewater using 3D Packed Bed Bipolar Electrode System)

  • 김한기;정주영;신자원;박주양
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.409-421
    • /
    • 2012
  • Ethanolamine (ETA) is mainly used to prevent corrosion of pipe in secondary cooling system of nuclear power plant. Condensed ETA in wastewater could increase COD and T-N when it was emitted to natural water system. Compared to conventional treatments, electrochemical oxidation process using packed bed bipolar electrodes was adopted to treat COD and T-N. According to arrangement of feeder electrode, single packed bed bipolar electrode reactor and multi-paired packed bed bipolar reactor were developed and conventional zero-valent iron (ZVI) was selected as conducting bipolar electrode. Bipolar electrodes were coordinated three-dimensionally in the reactor. The experimental results showed that COD and T-N was little removed in unit system at different pH condition (pH 8 and 11) on 100V. However, in multi-paired system that applied 600V, COD was eliminated 80.85% (anode-cathode-anode, A-C-A) and 85.11% (cathode-anode-cathode, C-A-C), respectively. T-N was also removed 96.88% (A-C-A) and 90.63% (C-A-C), simultaneously. Current efficiency was estimated both single and multi-paired system. At unit bipolar packed bed reactor, current efficiency was almost zero, however in multi-paired system, current efficiency was 300~500% at A-C-A and 250~350% at C-A-C. Current efficiency was over 100% hence it was confirmed that this system is more effective than conventional electrochemical oxidation system.

네모파 전압전류법 측정을 위한 블루투스 기반 휴대형 포텐쇼스탯 (A Portable Potentiostat with Bluetooth Communication for Square wave Voltammetry Measurement)

  • 심원식;한지훈;김수윤;권현정;박정호
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.622-627
    • /
    • 2016
  • This paper describes the development of a portable potentiostat which can perform square wave voltammetry on electrochemical sensors and wireless transmission of the measured data to a smartphone using Bluetooth. The potentiostat consists of a square wave potential pulse generation circuit for applying the potential pulse to the electrochemical sensor, a reduction/oxidation (or redox) current measurement circuit, and Bluetooth for wireless data transmission to an Android-based smartphone. The measured data are then processed to show the output graph on the smart phone screen in real time. This data transformation into a graph is carried out by developing and installing a simple transformation application software in the Android-based smartphone. This application software also enables the user to set and change the measurement parameters such as the applied voltage range and measured current range at user's convenience. The square voltammetry output data measured with the developed portable potentiostat were almost same as the data of the commercial potentiostat. The measured oxidation peak current with the commercial potentiostat was $11.35{\mu}A$ at 0.26 V and the measured oxidation peak current with the developed system was $12.38{\mu}A$ at 0.25 V. This proves that performance of the developed portable measurement system is comparable to the commercial one.

PEO 전류밀도 조건에 따른 알루미늄도금 강재상 산화코팅막의 특성 (Characteristics of Coating Films on Hot-Dipped Aluminized Steel Formed by Plasma Electrolytic Oxidation Process at Different Current Densities)

  • 최인혜;이훈성;이명훈
    • 한국표면공학회지
    • /
    • 제50권5호
    • /
    • pp.366-372
    • /
    • 2017
  • Plasma electrolytic oxidation(PEO) has attracted attention as a surface treatment which has high wear resistance and corrosion resistance. PEO is generally considered as cost-effective, environmentally friendly and superior in terms of coating performance. Most of studies about the PEO processes have been applied to light metals such as Al and Mg. Because the strength of Al and Mg is weaker than that of steel, there is a limit to the application. In this study, PEO process was used to form oxide coatings on Hot dipped aluminized(HDA) steel and the characteristics of the coating film according to the PEO current density were studied. The morphology was observed by SEM and component was analyzed by using EDS. The corrosion behaviors of PEO coating films were estimated by exposing salt spray test at 5 wt.% NaCl solution and measuring polarization curves in deaerated 3 wt.% NaCl solution. With the increase of PEO process current density, the pore size of the coating surface and the thickness of coating increased. It was confirmed that no Fe component was present on the coating surface. PEO coating films obviously showed good corrosion resistance compared with HDA. It is considered that the PEO coating acts as a barrier to protect the base material from external factors causing corrosion.

Kinetic Study of the Electrooxidation of Mefenamic Acid and Indomethacin Catalysed on Cobalt Hydroxide Modified Glassy Carbon Electrode

  • Saghatforoush, Lotfali.;Hasanzadeh, Mohammad.;Karim-Nezhad, Ghasem.;Ershad, Sohrab.;Shadjou, Nasrin.;Khalilzadeh, Balal.;Hajjizadeh, Maryam.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권6호
    • /
    • pp.1341-1348
    • /
    • 2009
  • Electrocatalytic oxidation of two anti-inflammatory drugs (Mefenamic acid and Indomethacin) was investigated on a cobalt hydroxide modified glassy carbon (CHM-GC) electrode in alkaline solution. The process of oxidation and its kinetics were established by using cyclic voltammetry and chronoamperometry techniques as well as steady state polarization measurements. Voltammetric studies indicated that in the presence of under study drugs, the anodic peak current of low-valence cobalt species increased, followed by a decrease in the corresponding cathodic current. This result indicates that the drugs were oxidized via cobalt hydroxide species immobilized on the electrode surface via an E$\acute{C}$ mechanism. A mechanism based on the electrochemical generation of Co (IV) active sites and their subsequent consumption by the drugs in question was also investigated. The constants rate of the catalytic oxidation of the drugs and the electron-transfer coefficients reported.