• Title/Summary/Keyword: oxidation current

Search Result 723, Processing Time 0.03 seconds

The Microstructures and Mechanical Properties on the GTA Welding conditions of Inconel 617 (Inconel 617 GTA 용접조건에 따른 미세조직 특성 및 기계적성질)

  • Choe, Seong-Bu;Lee, Bong-Geun;Gang, Jeong-Yun
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.171-173
    • /
    • 2005
  • Inconel 617 is a solid solution, nickel-chromium-cobalt-molybdenum alloy with an exceptional combination of high temperature strength and oxidation resistance. The combination of high strenth and oxidation resistance at temperatures over $1800^{\circ}F$ makes Inconel 617 an attractive material for such components as ducting, transition liners in both aircraft and gas turbine. In this study, the weldability and weldment characteristics of Inconel 617 are considered in GTAW associated with the two welding current and with back shielding gas using or not. After GTAW with 120A and 150A current, microstructures and hardness test, bending test, tensile test on room and elevated temperature for the determination of optical welding condition.

  • PDF

Electrochemistry Characterization of Nickel Using Ethanolamine Compound Additives (에탄올아민화합물 첨가에 대한 니켈의 전기화학적 특성)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.531-538
    • /
    • 2010
  • The electrochemistry characterization of metal is important in many industrial applications. In this study, we investigated the C-V diagrams related to the electrochemistry characterization of nickel. We determined electrochemical measurement by using cyclic voltammetry with a three electrode system. A measuring range was reduced from initial potential to -1350mV, continuously oxidized to 1650mV and measured to the initial point. The scan rate were 100, 150, 200 and 200mV/s. As a result, the C-V characterization of nickel using ethanolamine and ethylethanolamine inhibitor appeared irreversible process caused by the oxidation current from the cyclic voltammogram. After adding ethanolamine compound additive, adsorption film constituted, and the passive phenomena happened. According to the results by cyclic voltammetry method, it was revealed that the effect of the electrochemistry characterization of nickel depends on ethanolamine structure interaction to adsorption complex.

A Method for Real Time Monitoring of Oxide Thickness in Plasma Electrolytic Oxidation of Titanium

  • Yoo, Kwon-Jong;Lee, Yong-K.;Lee, Kang-Soo
    • Corrosion Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.8-11
    • /
    • 2010
  • During PEO (plasma-electrolytic-oxidation) treatment of titanium, the relationship between the thickness of oxide film and the measured electrical information was investigated. A simple real time monitoring method based on the electrical information being gathered during PEO treatment is proposed. The proposed method utilizes the current flowing from a high frequency voltage source to calculate the resistance of an oxide film, which is converted into the thickness of an oxide film. This monitoring method can be implemented in PEO system in which an oxide film is grown by constant or pulsed voltage/current sources.

Voltammetric Determination of Bisphenol A Using a Carbon Paste Electrode Based on the Enhancement Effect of Cetyltrimethylammonium Bromide (CTAB)

  • Huang, Wensheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1560-1564
    • /
    • 2005
  • The influence of cetyltrimethylammonium bromide (CTAB) on the electrochemical behavior of bisphenol A at the carbon paste electrode (CPE) was investigated. CTAB, with a hydrophobic C-H chain, can adsorb at the CPE surface via hydrophobic interaction and then change the electrode/solution interface, and finally affects the electrochemical response of bisphenol A, confirming from the remarkable oxidation peak current enhancement. The electrode process of bisphenol A was examined, and then all the experimental parameters which affects the electrochemical response of bisphenol A, such as pH value of the supporting electrolyte, accumulation potential and time, potential scan rate and the concentration of CTAB, were examined. Finally, a sensitive and simple voltammetric method was developed for the determination of bisphenol A. Under the optimum conditions, the oxidation peak current of bisphenol A varied linearly with its concentration over the range from $2.5\;{\times}\;10^{-8}\;to\;1\;{\times}\;10^{-6}$ mol/L, and the detection limit was found to be $7.5\;{\times}\;10^{-9}$ mol/L. This method was successfully employed to determine bisphenol A in some waste plastic samples.

Electrochemical Properties of Mixture Langmuir-Blogett Films of Fatty Acid containing Azobenzene and Phospholipid (아조벤젠기를 가진 지방산과 인지질 혼합 LB막의 전기화학적 특성)

  • Park, Keun-Ho;Choi, Sung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.920-923
    • /
    • 2004
  • We have investgated on the monolayer LB film of BASH-DMPC mixture on an ITO for the photoisomerization by light irradiation. We measured electrochemical properties by using cyclic voltammetry with a three-electrode system, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode in $NaClO_4$ solution at a variable concentration and monolayer LB films. A measuring range was reduced from initial potential to -1350mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150 and 200 mV/s. As a results, LB films of 8A5H-DMPC appeared reversible process caused by the reduction-oxidation current from the cyclic voltammogram.

  • PDF

Electro-Catalytic Behavior of an Antiarrhythmic Drug, Procainamide and its Electro-Analytical Applications

  • Abbar, Jyothi C.;Meti, Manjunath D.;Nandibewoor, Sharanappa T.
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.292-300
    • /
    • 2018
  • The electrocatalytic oxidative behavior of an antiarrhythmic drug, procainamide hydrochloride (PAH) at the gold electrode surface has been examined using different voltammetric methods like cyclic, linear-sweep and differential pulse voltammetry. Voltammograms obtained in this study reveal that the electrode exhibit excellent electrocatalytic activity towards oxidation of the drug. The parameters that can affect the peak current at different pH, scan rate and concentration were evaluated. The number of electrons transferred was calculated. The current displayed a wide linear response ranging from 0.5 to $30.0{\mu}M$ with a limit of detection of 56.4 nM. The impact of potential interfering agents was also studied. The electrode displayed wide advantages such as simple sample preparation, appreciable repeatability, reproducibility and also high sensitivity. Furthermore, the feasibility of the proposed method was successfully demonstrated by determining PAH in the spiked human biological sample.

Effect of AC Current Density on the PEO Film Formation of Al6061 Alloy (Al6061합금의 PEO 피막 형성에 미치는 AC 전류밀도의 영향)

  • Park, Cheolgi;Moon, Sungmo;Cheong, Inmo;Yun, Daesoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.138-144
    • /
    • 2019
  • In this work, PEO (Plasma Electrolytic Oxidation) film formation behavior of Al6061 alloy was investigated as a function of applied current density of AC at 310 Hz in the range from $120mA/cm^2$ to $300mA/cm^2$ in 0.5 M $Na_2SiO_3$ solution. When applied current density is lower than a critical voltage of about $132mA/cm^2$, voltage reaches a steady-state values less than 120 V without generation of arcs and metallic color of the alloy surface remains. On the other hand, when applied current density exceeds about $132mA/cm^2$, voltage increases continuously with time and arcs are generated at more than 175 V, resulting in the formation of PEO films with grey colors. Two different types of arcs, large size and small number of arcs with orange color, and small size and large number of arcs with white color, were generated at the same time when the PEO film thickness exceeds about $50{\mu}m$, irrespective of applied current density. Formation efficiency of the PEO films was found to increase with increasing applied current density and the growth rate was obtained to be about $5{\mu}m/min$ at $300mA/cm^2$. It was also found that surface roughness of the PEO films with $70{\mu}m$ thickness is not dependent on the applied current density.

Low Potential Amperometric Determination of Ascorbic Acid at a Single-Wall Carbon Nanotubes-Dihexadecyl Hydrogen Phosphate Composite Film Modified Electrode

  • Fei, Junjie;Wu, Kangbing;Yi, Lanhua;Li, Junan
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.9
    • /
    • pp.1403-1409
    • /
    • 2005
  • A sensitive and selective electrochemical method was developed for the amperometric determination of ascorbic acid (AA) at a glassy carbon electrode (GCE) modified with single-wall carbon nanotubesdihexadecyl hydrogen phosphate (SWNT-DHP) composite film. The SWNT-DHP composite film modified GCE was characterized with SEM. The SWNT-DHP composite film modified GCE exhibited excellent electrocatalytic behaviors toward the oxidation of AA. Compared with the bare GCE, the oxidation current of AA increased greatly and the oxidation peak potential of AA shifted negatively to about -0.018 V (vs. SCE) at the SWNT-DHP composite film modified GCE. The experimental parameters, which influence the oxidation current of AA, were optimized. Under the optimal conditions, the amperometric measurements were performed at a applied potential of -0.015 V and a linear response of AA was obtained in the range from 4 ${\times}$ $10^{-7}$ to 1 ${\times}$ $10^{-4}$ mol $L^{-1}$ and with a limit of detect (LOD) of 1.5 ${\times}$ $10^{-7}$ mol $L^{-1}$. The interferences study showed that the SWNT-DHP composite film modified GCE exhibited good sensitivity and excellent selectivity in the presence of high concentration uric acid and dopamine. The proposed procedure was successfully applied to detect AA in human urine samples with satisfactory results.

The Effect of Load Conditions for the Power of Mg-Air Fuel Cell (부하조건이 마그네슘-공기연료전지의 출력특성에 미치는 영향)

  • Kim, Yong-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.134-139
    • /
    • 2012
  • The power characteristics of the Mg-Air fuel cell were investigated with regard to variation of load conditions. The types of load current using for the Mg-Air fuel cell with 10% NaCl electrolyte were step type, ramp type and pulse type. It was found that transient phenomena occurred in the step current load, which is due to activate of the oxidation-reduction reaction process. And the transient time increase with the load current increase. In the load current of ramp type, the slop of voltage drop increased with current load slop ${\alpha}$ increase. The load voltage and power decreased according to the pulse period of load current decrease were attributed to the metal sludges.

Effects of Increase in Ratio of Phenolic Hydroxyl Function on Carbon Fiber Surfaces by Anodic Oxidation on Mechanical Interfacial Bonding of Carbon Fibers-reinforced Epoxy Matrix Composites (양극산화 처리에 따른 탄소섬유 표면의 페놀릭 하이드록실 관능기 비율의 증가가 에폭시기지 복합재료의 기계적 계면결합 특성에 미치는 영향)

  • Kim, Dong-Kyu;Kim, Kwan-Woo;Han, Woong;Song, Bhumkeun;Oh, Sang-Yub;Bang, Yun Hyuk;Kim, Byung-Joo
    • Applied Chemistry for Engineering
    • /
    • v.27 no.5
    • /
    • pp.472-477
    • /
    • 2016
  • We studied the effects of anodic oxidation treatments of carbon fibers on interfacial adhesion of the carbon fibers-reinforced epoxy matrix composites with various current densities. The surface of treated carbon fibers was characterized by atomic force microscope (AFM), field emission-scanning electron microscope (FE-SEM), Fourier transform infrared spectroscopy (FT-IR), and X-ray photoelectron spectroscopy (XPS). The interlaminar shear strength (ILSS) of the composites was determined by a short beam shear test. This result showed that both the roughness and oxygen group of the carbon fibers surface increased in proportion to the current density. After anodic-oxidation-treated, the ILSS also increased as a function of the current density. In addition, the proportional relationship between ILSS and phenolic hydroxyl group was confirmed. The ILSS of the CF-2.0 sample increased by 4% compared to that of the CF-AS sample, because the anodic oxidation treatment increased the oxygen group and roughness on the carbon fibers surface, which leading to the improvement of the interfacial adhesion of the carbon fibers-reinforced epoxy matrix composites. Among these, the phenolic hydroxyl group which has the proportional relationship with ILSS is found to be the most important factor for improving the interfacial adhesion of the carbon fibers-reinforced epoxy matrix composites.