• 제목/요약/키워드: overlapped beam

검색결과 35건 처리시간 0.025초

12%-Cr 강의 C0$_{2}$레이저 표면 경화

  • 김재도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 춘계학술대회 논문집
    • /
    • pp.84-88
    • /
    • 1992
  • Laser beam hardenling of 12%-Cr steel has been evaluated by using a continuous wave 3 kW CO$\_$2/ laser with a hardening mirror set. Experiment was performed on the optimum hardening condition with a laser power of 2.85kW and travel speed of 10 and 5 m/min. Multi passes have been alsotried to find the hardening characteristics of partly overlapped zone. The black paint to use at high temperature was adopted to increases the absorptivity of laser beam energy with the wavelength of 10.6 .mu. m at the surface of bese metal. The microstructure of the hardened layers was observed by using a light microscopy. SEM and TEM. A fine lamellar martensite formed in the hardened zones exhibits very high Vickers microhardness of 600 Hv, whereas the tempered martesite distributes in the base metal with Vickers microhardness of 240 Hv. It has been found that laser hardening with multi pass showed no significant drop of the hardness between adjacent passes.

비동위치화된 센서와 액추에이터를 이용한 외팔보의 끝단 진동에 대한 직접속도 피드백제어 (Direct Velocity Feedback for Tip Vibration Control of a Cantilever Beam with a Non-collocated Sensor and Actuator Pair)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.109-114
    • /
    • 2004
  • This paper presents a theoretical and experimental study of a non-collocated pair of piezopolymer PVDF sensor and piezoceramic PZT actuator, which are bonded on a cantilever beam, in order to suppress unwanted vibration at the tip of the beam. The PZT actuator patch was bonded near the clamped part and the PVDF sensor, which was triangularly shaped, was bonded on the other part of the beam. This is because the triangular PVDF sensor is known that it can detect the tip velocity of a cantilever beam. Because the arrangement of the sensor and actuator pair is not collocated and overlapped each other, the pair can avoid so called 'the in-plane coupling'. The test beam is made of aluminum with the dimension of $200\times20\times2mm$, and the two PZT5H actuators are both $20\times20\times1mm$ and bonded on the beam out-of-phase, and the PVDF sensor is $178mm\times6mm\times52{\mu}m$. Before control, the sensor-actuator frequency response function is confirmed to have a nice phase response without accumulation in a reasonable frequency range of up to 5000 Hz. Both the DVFB and displacement feedback strategies made the error signal from the tip velocity (or displacement) sensor is transmitted to a power amplifier to operate the PZT actuator (secondary source). Both the control methods attenuate the magnitude of the first two resonances in the error spectrum of about 6-7 dB.

  • PDF

Ultimate strength behavior of steel-concrete-steel sandwich beams with ultra-lightweight cement composite, Part 2: Finite element analysis

  • Yan, Jia-Bao;Liew, J.Y. Richard;Zhang, Min-Hong
    • Steel and Composite Structures
    • /
    • 제18권4호
    • /
    • pp.1001-1021
    • /
    • 2015
  • Ultra-lightweight cement composite (ULCC) with a compressive strength of 60 MPa and density of $1,450kg/m^3$ has been developed and used in the steel-concrete-steel (SCS) sandwich structures. This paper investigates the structural performances of SCS sandwich composite beams with ULCC as filled material. Overlapped headed shear studs were used to provide shear and tensile bond between the face plate and the lightweight core. Three-dimensional nonlinear finite element (FE) model was developed for the ultimate strength analysis of such SCS sandwich composite beams. The accuracy of the FE analysis was established by comparing the predicted results with the quasi-static tests on the SCS sandwich beams. The FE model was also applied to the nonlinear analysis on curved SCS sandwich beam and shells and the SCS sandwich beams with J-hook connectors and different concrete core including ULCC, lightweight concrete (LWC) and normal weight concrete (NWC). Validations were also carried out to check the accuracy of the FE analysis on the SCS sandwich beams with J-hook connectors and curved SCS sandwich structure. Finally, recommended FE analysis procedures were given.

동축 파이프 이음부의 레이저용접 공정변수에 관한 연구 (Study on the Process Parameters for Laser Welding of Coaxial Circular Pipe Inner Flange)

  • 김용;박기영;이경돈
    • 한국레이저가공학회지
    • /
    • 제12권3호
    • /
    • pp.14-17
    • /
    • 2009
  • The laser welding was performed for the flange joint of two overlapped coaxial circular pipes which serve as the inlet and connector pipes of STS 316L. The laser welding test finally resulted in a good penetration depth of 1.8 to 2.0 mm. On the way to get the good welding quality, two important parameters were found to be optimized. One is the focal positioning which is the offset of the laser beam focus to the exact welding seam line, which is more critical in the inner flange laser welding. When the beam spot size was deviated more than $200\;{\mu}m$ from the seam line, welding of two pipes is failed. The other is a gap size since a certain amount of gap is inevitable due to fabrication tolerance, or artificial allowances for smooth insertion of a pipe. However, it is required to restrict the gap allowance within 0.2mm to avoid undesirable undercut on a welding bead.

  • PDF

파이버 레이저를 이용한 치과용 임플란트 표면처리에 관한 연구 (A Study on the Surface Treatment of Dental Implant using a Fiber Laser)

  • 신호준;양윤석;황찬연;유영태
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.915-928
    • /
    • 2011
  • Titanium for dental implant application has the superior properties of biocompatibility, specific strength, and corrosion resistance. However, it is extremely difficult to find a suitable surface treatment method for sufficient osseointegration with biological tissue/bone cell and implant surface. Surface treatment technology using laser has been researched as the way to increase surface area of implant. In this study, to develop the surface treatment process with improved adhesion between implant and bone cell at the same time for superior biocompatibility, pulsed laser beam was overlapped continuously for scribed surface morphology and determination of friction coefficient. As the results, surface area and friction coefficient was increased over 2 times by the comparison with sand blasting, which is used for the conventional method. In this time, the optimal condition for laser beam power and beam irradiation speed was 13 watt and 50 mm/sec, respectively.

상악동저와 상악 대구치 치근의 위치 관계: 파노라마방사선사진과 Cone beam형 전산화단층영상의 비교 (Comparison of panoramic radiography and cone beam computed tomography for assessing the relationship between the maxillary sinus floor and maxillary molars)

  • 정연화;조봉혜
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.69-73
    • /
    • 2009
  • Purpose: This study compared panoramic radiography and cone beam computed tomography (CBCT) for evaluating the relationship between the maxillary sinus floor and the roots of maxillary molars. Materials and Methods: Paired panoramic radiographs and CBCT images from 97 subjects were analysed. This analysis classified 388 maxillary molars according to their relationship to the maxillary sinus floor on panoramic radiograph and CBCT. Correlations between these two radiographic techniques were examined. Results: Maxillary molar roots that were separate from the sinus floor showed the same classification in 100% of the cases when using these two imaging techniques. The corresponding percentage for such roots that were in contact with the sinus floor was 75%. When roots overlapped the maxillary sinus floor on panoramic radiographs, only 26.4% of maxillary first molars and 60.0% of second molars showed protrusion of roots into the sinus with CBCT. Conclusion : The results of the study suggest that roots projecting into the sinus on panoramic radiographs require a three-dimensional image in order to analyze the proximity of their apex to the sinus floor. (Korean J Oral Maxillofac Radiol2009; 39 : 69-73)

  • PDF

멀티패스 레이저 클래딩에 있어서 중첩률의 기준에 따른 클래드 층의 특성 비교 (Comparison of clad layer characteristics with overlapping criterion in multi pass laser cladding)

  • 김종도;이은진;황준구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권9호
    • /
    • pp.768-773
    • /
    • 2016
  • 엔진 밸브 시트와 페이스는 엔진 성능에 영향을 미치므로 내마모성, 내열성 및 내식성이 요구된다. 이러한 특성을 갖는 표면층을 형성하기 위해 일반적으로 PTA 프로세스를 사용하고 있지만 넓은 열 영향부와 높은 모재 희석 등과 같은 문제가 발생한다. 이러한 단점을 개선한 레이저 클래딩은 희석률이 낮고 열 영향 및 열 변형을 최소화하므로 더욱 우수한 클래드 층을 형성할 수 있다. 하지만 레이저 빔의 특성상 넓은 면적을 클래딩 할 경우, 1 패스 클래드 층의 중첩이 불가피하다. 중첩률 기준을 빔 사이즈와 클래드 층 폭으로 나누어 멀티패스 클래드 층을 형성한 결과, 기준에 관계없이 중첩률이 증가할수록 클래드 층의 폭이 감소하고 높이가 증가하였다. 하지만 빔 사이즈 기준 중첩률 조건으로 형성된 멀티패스 클래드 층이 다른 기준보다 모재 희석이 감소하여 더욱 높은 경도 값을 나타내었다. 결론적으로, 중첩률 기준을 클래드 층 폭으로 할 경우, 클래드 층 형상에 영향을 주는 공정변수가 변할 때 마다 폭의 길이가 달라지기 때문에 빔 사이즈를 중심으로 중첩률을 정의하였다.

전자빔 패터닝과 double-angle 그림자 증착법을 이용한 sub-micron 크기의 $Al-AlO_x-Al$ 터널접합 제작공정개발 (Fabrication of Sub-Micron Size $Al-AlO_x-Al$ Tunnel Junction using Electron-Beam Lithography and Double-Angle Shadow Evaporation Technique)

  • ;최재원;류시정;박정환;류상완;김정구;송운;정연욱
    • Progress in Superconductivity
    • /
    • 제10권2호
    • /
    • pp.99-102
    • /
    • 2009
  • We report our development of the fabrication process of sub-micron scale $Al-AlO_x-Al$ tunnel junction by using electron-beam lithography and double-angle shadow evaporation technique. We used double-layer resist to construct a suspended bridge structure, and double-angle electron-beam evaporation to form a sub-micron scale overlapped junction. We adopted an e-beam insensitive resist as a bottom sacrificing layer. Tunnel barrier was formed by oxidation of the bottom aluminum layer between the bottom and top electrode deposition, which was done in a separate load-lock chamber. The junction resistance is designed and controlled to be 50 $\Omega$ to match the impedance of the transmission line. The junctions will be used in the broadband shot noise thermometry experiment, which will serve as a link between the electrical unit and the thermodynamic unit.

  • PDF

다중빔 음향측심기 수심 정확도 개선 (Improvement of Multi-beam Echo Sounder's Depth Accuracy)

  • 최철웅;김연수;서용철
    • 한국측량학회지
    • /
    • 제23권1호
    • /
    • pp.1-8
    • /
    • 2005
  • 다중빔 음향측심기는 수심의 3∼4배되는 주사 폭으로 넓은 지역을 동시에 측량하므로 자료의 정밀도와 작업효율성이 단빔 음향측심기보다 상대적으로 높다. 그러나 빔의 생성 및 계측 원리가 정교하여 탐사선의 움직임에 영향을 많이 받기 때문에 부가장치의 정확한 조정 작업이 필수적으로 요구된다. 본 연구에서는 다중빔 음향측심기의 정확도 향상을 목적으로 평탄 해저지형에서 빔의 중앙과 ± 45°의 빔각을 이루는 지역의 수심단면을 가시·통계적으로 분서한 결과, 관성센서의 진동과 부가장치의 오정렬에 의한 오차가 발생하여 부가장치에 대한 조정이 필요하였다. 따라서 방진재를 관성센서에 부착하여 선체로부터 받는 진동을 저감시키고, 선체 자세요소와 부가장치의 오프셋 값을 정밀 계측하여 수평자세요소 값으로 변환·정렬시켰다. 그 결과, ±45° 빔각 지역의 수심 정확도는 IHO S44의 1등급 수로측량 수준에서 특등급 수로측량 수준으로 향상되었으며, 오정렬에 의한 중첩구역의 물결무늬 현상도 현저히 감소하였다.

다중빔 음향측심기의 내수면 적용성 평가 (Applicability Evaluation of Multi Beam Echo Sounder for Inland Water)

  • 정진우;조광희;홍승서
    • 한국측량학회지
    • /
    • 제36권6호
    • /
    • pp.629-639
    • /
    • 2018
  • 본 연구에서는 영산강의 죽산보에서 죽산교까지 길이 약 840m, 폭 약 230m, 넓이 약 $0.16km^2$를 대상으로 단빔 음향측심기와 다중빔 음향측심기의 내수면 적용성을 분석하였다. 무인선에 단빔 음향측심기와 다중빔 음향측심기를 장착하고 각각의 데이터를 획득한 다음 비정규삼각망(TIN: Triangular Irregular Network)을 생성하고 10m 간격의 격자 수심을 추출하였다. 추출한 단빔 및 다중빔 음향측심기의 격자수심 총 5,024개의 데이터를 중첩 비교하여 다음의 결론을 얻을 수 있었다. 첫째, 수심의 차이는 평균 0.0319m로서 전체적으로 큰 차이는 없었으나 표준편차는 2.4095m로 크게 나타났다. 둘째, TIN으로 구현된 하상의 형태는 서로 유사하였으나, 다중빔의 하상면보다 높거나 낮은 단빔의 하상면 구역들의 체적은 총 $161,882m^3$의 차이가 있었다. 셋째, 대상지역 전체를 다중빔으로 스캔했을 때 단빔에 비해 운항 거리는 4,595.85m, 약 55% 정도 증가하였으며, 운항 시간은 59분, 약 47% 정도 증가하였다. 넷째, 작업공정, 투입인원 및 소요비용에서는 같거나 큰 차이가 없었다. 운항 거리나 운항 시간과 같은 작업 효율면에서 단빔을 장착했을 때보다 다중빔을 장착했을 때 효율이 약 0.5배 정도 낮은 것으로 판단되나, 하상변동 예측과 같이 하상면의 정확한 데이터가 필요한 분야에서는 다중빔 음향측심기를 이용한 데이터 획득이 필요한 것으로 판단된다.