• Title/Summary/Keyword: overheating

Search Result 259, Processing Time 0.025 seconds

Manufacture of Precsion Model Using Laser Melting Process (레이저 용융 적층 공정을 이용한 정밀 형상 제작)

  • 김재도;전병철;권택열;이영곤;신동훈
    • Laser Solutions
    • /
    • v.3 no.3
    • /
    • pp.21-29
    • /
    • 2000
  • For the direct metal shape processing the powder feed device which is different from the widely used in rapid prototyping. is developed, The three dimensional object is shaped with the melting metal powder. The developed research has applied to rapid prototyping in ultraprecision for MEMS and medical science fields required of rapid manufacture of complex shape. The goal of this study make 3D model which has precision accuracy. Powder spreading apparatus has been more improved because that the control of powder spread is very important in layer manufacturing. It consists of the vibration motor, nozzle and tube which supplies various metal powder. This apparatus could control the spreading velocity that could control powder spreading thickness. Laser on/off switch was adapted because laser scanning velocity must be preserved constantly to prevent heat transformation of laser overheating. The error between sintered thickness md experimental one occurred by shrinkage in sintering melting process. The problem of heat transformation was solved by On/Off switching system.

  • PDF

Study on the Utilization of HBD in the Conventional Speed-up Lines (일반철도 고속화 구간에서 차축온도검지장치 활용방안에 대한 연구)

  • Choe, Gwon-Hui;Kim, Yu-Ho;Baek, Seung-Mun;Bing, Gun-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.233-243
    • /
    • 2012
  • HBD(Hot Box Detector) is a device to monitor temperature rises to inappropriate lubricant use or mechanical defects. If a train operates without recognizing such an effect, it might result in bearing overheating due to defects and cause a dangerous situation that it could derail a train owing to the damage of axles. Now for the Gyeongbu HSL at 300km/h, the laws related to monitoring overheated axle bearings are notified in the Railway Safety Law and the Railway Construction Law. But in case of the conventional speed-up lines that a train operates at 180 to 230 km/h, the revised bill of relevant standards is ongoing. Therefore in this paper we present references and reviews investigated in order to use the optimal HBD in the conventional speed-up lines.

  • PDF

A "Fabric-First" Approach to Sustainable Tall Building Design

  • Oldfield, Philip
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.177-185
    • /
    • 2017
  • This research suggests the most effective way for improving energy efficiency in tall buildings is a "fabric-first" approach. This involves optimizing the performance of the building form and envelope as a first priority, with additional technologies a secondary consideration. The paper explores a specific fabric-first energy standard known as "Passivhaus". Buildings that meet this standard typically use 75% less heating and cooling. The results show tall buildings have an intrinsic advantage in achieving Passivhaus performance, as compared to low-rise buildings, due to their compact form, minimizing heat loss. This means high-rises can meet Passivhaus energy standards with double-glazing and moderate levels of insulation, as compared to other typologies where triple-glazing and super-insulation are commonplace. However, the author also suggests that designers need to develop strategies to minimize overheating in Passivhaus high-rises, and reduce the quantity of glazing typical in high-rise residential buildings, to improve their energy efficiency.

Application of Evaporative Cooling Technology in HDVC Converter Station

  • Guo, Jianhong;Wang, Haifeng;Ai, Chengliu;Gu, Guobiao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.105-109
    • /
    • 2014
  • Converter valve cooling device as the heat exchanger, is known as the converter valve's blood circulation system, Inefficiency of the equipment will not only lead to the component overheating damage, but also serious DC system outage. Therefore, reliable HVDC valve cooling system is essential for the HVDC transmission system. In this article, analysis on the two-phase flow heat transfer characteristics and security of the evaporative cooling technology are provided, the technology's advantage and feasibility are discussed.

Temperature Characteristics on Cooking Equipment Materials of Portable Gas Ranges (이동식부탄연소기의 조리기구재질에 따른 온도 특성)

  • Kim, Dae-Hyun;Lee, Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.8-13
    • /
    • 2014
  • Accidents involving portable ranges occurred total 133 cases for the last five years(2008~2012). It accounted for 18.0% of all gas accidents(739 cases). Major causes of accidents are using of excessive hot grill, leaving a butane can near fire and overheating of a butane can during cooking. In this study, it is a desire to investigate the relationship between thermal behavior mechanism depending on characteristics of cooking equipment materials of portable gas ranges. It shows that slope of temperature change curve correlates with difference of heat capacity on thermal behavior characteristics experiment depending on materials of cooking equipment. In conclusion, temperature characteristics appear differently depending on variables such as materials of cooking equipment. Especially, it is necessary to restrict using cooking equipment made of stones, because it is very dangerous that temperature of can is rapidly increasing caused by high heat capacity of stone.

Development of a Novel Passive Harmonic Filter (신개념 수동형 고조파 필터 개발과 성능에 관한 평가)

  • Park, Byoung-Ju;Lee, Han-Sang;Jang, Gil-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.29-36
    • /
    • 2006
  • The interest for harmonic problems has been increasing due to the increment of nonlinear loads. The loads such as DC power system, personal computers, UPS system, inverters and converters operate as harmonic current sources. In this paper, a new type of the passive filter, Hybrid Harmonic Filter (HHF) is suggested to mitigate harmonic problems in power systems. The HHF is developed for reducing harmonic current, especially on the system that includes 6-pulse bridge rectifiers. Also, it is expected to prevent the overheating of transformers and feeders due to overcurrent and to correct the power factor.

On-line Condition Monitoring of Thermal Accelerating Aged Transformer by Capacitive Sensor (전기용량 센서를 이용한 가속 열 열화 변압기의 온라인 상태진단)

  • Kim, Ju-Han;Han, Sang-Ok;Lee, Sei-Hyun;Kim, Han-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.82-84
    • /
    • 2005
  • In a transformer, thermal stress is the most influential parameter affecting the aging behavior of insulation system. The aging behavior of insulation system in transformer is determined mainly by the thermal conditions inside the transformer. The thermal stress on the insulation system may occur from operation in a high temperature caused by overloading or local overheating. Thus, this paper investigated the condition monitoring of insulation condition in thermally accelerated aged transformer oils by in-situ sensor. The condition of aged samples was investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. Results from the experiments are presented in this paper.

  • PDF

Analysis of Voltage Unbalance on Electric Railway System (전기철도 시스템의 불평형 해석)

  • Lee, Han-Min;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.184-190
    • /
    • 2005
  • The railway characteristic, which is concerned, as most utilities is unbalance produced by the large single-phase loads. Here are two theoretical concerns associated with unbalanced loads. First, generator rotor heating resulting from unbalanced current flow, Second, there is the possibility of motor overheating in industrial plants, due to the unbalanced voltage. Therefore, the exact assessment of the voltage unbalance must be carried out preferentially as well as load forecast at stages of designing and planning for the electric railway system. This paper proposes a new analysis model to more effectively estimate voltage unbalance. Numerous distributed circuits in the electric railway system are composed by components. The entire system can be easily modeled by the combination of four-port representation of each component in parallel and/or series. Simulation results using the model are compared with field data, and it verifies the accuracy of the proposed model.

  • PDF

A Study on Mechanical Characteristic Analysis for Main Transformer of High Speed Railway (고속철도차량 주변압기 기계적 특성 분석)

  • Han, Young-Jae;Kim, Seog-Won;Lee, Tae-Hyoung;Koo, Hun-Mo;Cho, Kwong-Woo;Park, Sang-Ock
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.713-718
    • /
    • 2006
  • In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measuring system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measuring system, KRRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.

  • PDF

The diagnosis and analysis for the correct design of electrical system in water treatment plan(Dissolved Air FIotation Process) (고도정수처리(DAF) 정수장 전력설비 적정 설계를 위한 고조파 현장 측정 및 분석)

  • Kim, Dong-Ryong;Kim, Gi-Tae;Han, Byong-Ok;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.61-63
    • /
    • 2007
  • In these days there are many troubles - system data error, control malfunctions, cable overheating - in water treatment plant. Specially DAF(Dissolved Air Floation Process) plant has high frequency than previous water treatment process. DAF plant has diverse equipment, nonlinear loads for the precise control. But there is no sufficient overall study about harmonics condition of water treatment plant just taking a following partial action without a fundamental solution. On designing of power system, designer should have regard to harmonics condition, but there is no guide reflected harmonics condition on DAF plant This study says what is the result of guideless design about harmonics. With the result of diagnosis and analysis in DAF plant, economical efficiency and safety of plant will be upgraded in the next design.

  • PDF