• Title/Summary/Keyword: over-saturation

Search Result 368, Processing Time 0.025 seconds

A Modified Current Differential Relaying Algorithm for Transformer Protection Considered by a Remanent Flux (잔류자속을 고려한 변압기 보호용 수정 전류차동 계전방식)

  • Kang, Y.C.;Jin, E.S.;Won, S.H.;Lim, U.J.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.262-265
    • /
    • 2003
  • During magnetic inrush or over-excitation saturation of the core in a transformer draws a large exciting current. This can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. In order to cope with the remanent flux at the beginning. the start of saturation of the core is detected and the core flux at the instant is estimated by inserting the differential current into a magnetization curve. Then, this core flux value can be used to calculate the core flux. The proposed relay calculates the core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss current and the magnetizing current from the conventional differential current. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

  • PDF

Reference Model Feedback Control and Stability Evaluation for Control System with Hard Non-linearities (견비선형을 갖는 제어시스템에 대한 기준모델 피드백제어 및 안정성평가)

  • Jung, Yu-Chul;Lee, Gun-Bok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.72-78
    • /
    • 2006
  • The paper proposes reference model error feedback control scheme for motion control system with hard non-linear components as like saturation and dead-zone in plant input part. Additionally, the plant has the system uncertainty effected by plant model parameter deviation and disturbance. The control algorithm uses the reference model to apply additional feedback loop with the error between reference model output and actual output effected by disturbance and non-linear components. And the stability evaluation based on Popov stability and controller design method are formulated to be performed. The effectiveness of the proposed scheme is examined by simulations. The results are proven by reasonable performances following reference model responses with good disturbance rejection performance without over-tuning of controller.

Performance Comparison of Cubic Equations of State With Two Temperature Dependent Parameters (두 개의 온도 의존 매개변수가 있는 3차 상태방정식의 성능비교)

  • Kwon, Young-Wook;Park, Kyoung-Kuhn
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.205-210
    • /
    • 2001
  • Cubic equations of state with two temperature dependent parameters are suggested and optimized using ASHRAE data for methane, propane, carbon dioxide, R-32 and R-134a. Appropriate simple functional forms are assumed for the temperature dependent parameters. The equations tested are Martin, Fuller, Harmens-Knapp, Schmidt-Wenzel. Among them modified Schmidt-Wenzel equation of state appears to be the choice for calculation of saturation properties such as vapor pressures, saturated liquid volumes, and saturated vapor volumes with an average absolute deviation of about one percent over the entire region excluding; the near cirtical.

  • PDF

D-band Stacked Amplifiers based on SiGe BiCMOS Technology

  • Yun, Jongwon;Kim, Hyunchul;Song, Kiryong;Rieh, Jae-Sung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.276-279
    • /
    • 2015
  • This paper presents two 3-stage D-band stacked amplifiers developed in a $0.13-{\mu}m$ SiGe BiCMOS technology, employed to compare the conventional cascode topology and the common-base (CB)/CB stacked topology. AMP1 employs two cascode stages followed by a CB/CB stacked stage, while AMP2 is composed of three CB/CB stacked stages. AMP1 showed a 17.1 dB peak gain at 143.8 GHz and a saturation output power of -4.2 dBm, while AMP2 showed a 20.4 dB peak gain at 150.6 GHz and a saturation output power of -1.3 dBm. The respective power dissipation was 42.9 mW and 59.4 mW for the two amplifiers. The results show that CB/CB stacked topology is favored over cascode topology in terms of gain near 140 GHz.

A Current Differential Relay for Transformer Protection with a Blocking Method Using the Difference-Function of a Differential Current (차전류 차분 블로킹 변압기 보호용 전류차동 계전기)

  • 강용철;원성호;김대성;양성채
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.691-697
    • /
    • 2003
  • This paper proposes a current differential relay for transformer protection that operates in accordance with a blocking method based on the difference-function of a differential current. For magnetic inrush and over-excitation, discontinuities in the first-difference function of the differential current arise at the points of inflection, which correspond to the start and end of each saturation period of the core. These discontinuities are converted into the pulses in the second- and third-difference functions of the differential current. The magnitudes of the pulses are large enough to detect saturation of the core. A blocking signal is issued if the magnitude of the third-difference function exceeds the threshold and is maintained for three quarters of a cycle. The performance of the relay is assessed under various conditions with magnetic inrush, internal faults and external faults. The proposed blocking method can improve significantly the operating time of a relay and achieve high sensitivity of a relay.

Measuring thermal conductivity and water suction for variably saturated bentonite

  • Yoon, Seok;Kim, Geon-Young
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.1041-1048
    • /
    • 2021
  • An engineered barrier system (EBS) for the disposal of high-level radioactive waste (HLW) is composed of a disposal canister with spent fuel, a buffer material, a gap-filling material, and a backfill material. As the buffer is located in the empty space between the disposal canisters and the surrounding rock mass, it prevents the inflow of groundwater and retards the spill of radionuclides from the disposal canister. Due to the fact that the buffer gradually becomes saturated over a long time period, it is especially important to investigate its thermal-hydro-mechanical-chemical (THMC) properties considering variations of saturated condition. Therefore, this paper suggests a new method of measuring thermal conductivity and water suction for single compacted bentonite at various levels of saturation. This paper also highlights a convenient method of saturating compacted bentonite. The proposed method was verified with a previous method by comparing thermal conductivity and water suction with respect to water content. The relative error between the thermal conductivity and water suction values obtained through the proposed method and the previous method was determined as within 5% for compacted bentonite with a given water content.

Novel Defog Algorithm via Evaluation of Local Color Saturation (국부영역 색포화 평가 방법을 통한 안개제거 알고리즘)

  • Park, Hyungjo;Park, Dubok;Ko, Hanseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.119-128
    • /
    • 2014
  • This paper presents a new method for improving the quality of images corrupted by an external source that generates an attenuation and scattering of light like dust, water droplets and fog. Conventional defog methods typically encounter a distortion such that the restored image has low contrast and oversaturation of color in some regions because of the mis-estimated airlight and wrong media transmission. Therefore, in order to mitigate these problems, we propose a robust airlight selection method and local saturation evaluation method for estimating media transmission. The proposed method addresses the wrong media transmission and over-saturation problems caused by the mis-estimated airlight and thereby improves the restored image quality. The results of relevant experiments of the proposed method against conventional ones confirm the improved accuracy of atmospheric light estimation and the quality of restored images with regard to objective and subjective performance measures.

Roundabout Signal Metering Operation Methods by Considering Approach Lane's Degree of Saturation (접근로별 포화도를 고려한 Roundabout Signal Metering 운영방법에 관한 연구)

  • Ahn, Woo-Young;Lee, So-Young
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.217-226
    • /
    • 2013
  • PURPOSES : Under the capacity conditions with balanced approach flows, roundabouts give less delay than existing signalized intersections; however, flows over 450 vehicles/hour/lane with unbalanced approach flow conditions, roundabouts efficiency drops due to the short time difference between the critical gap and the follow-up headway. The purpose of this study is developing a roundabout Signal Metering operation method by considering approach lanes degree of saturation. METHODS : A four-way-approach with one-lane roundabout is selected to compare the Signal Metering performance for the case of 16 different unbalanced flow conditions. Based on these traffic conditions, the performance is evaluated for 64 different cases of Signal Metering combinations by using SIDRA software. A degree of saturation(V/C ratio) sum for two adjoined approaches is used for the performance index of choosing Metered Approach and Controlling Approach. RESULTS : When the V/C ratio sum is 0.29~0.81 and Metered Approach flow is less than Controlling Approach flow, the average delay saving per vehicle is about 7 seconds; however, after this rage the delay saving decreases gradually until the V/C ratio sum reaches around 1.0. The range of V/C ratio sum 0.93~1.09 provides average delay saving per vehicle about 3 seconds. In case of V/C ratio sum is grater than 1.0 and the flows of Metered Approach is grater than Controlling Approach, the average delay per vehicle increases 3~11 times respectively. CONCLUSIONS : As expected, the Signal Metering provides substantial improvements in delay saving for the case of V/C ratio sum is 0.3~1.0 under the traffic flow conditions of Metered Approach is less than Controlling Approach.

Epidemiological Study of Air Pollution and Its Effects on Health of Urban Population (서울시(市) 대기오염(大氣汚染)이 시민보건(市民保健)에 미치는 영향(影響)에 관(關)한 조사연구(調査硏究))

  • Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.2 no.1
    • /
    • pp.5-22
    • /
    • 1969
  • The urban population of our country is rapidly increasing due to many factors of social structure, and sociologists are predicting that the increase rate of the urban population will be over 50% in 1980's. Above all, the population of the capital city of Seoul, is at present more than four millions. Such centring of people in cities, together with the improvement of the standards of living, caused rapid increase in the amount of fuel consumption, and this consumption of fuels became one of the primary sources of the air pollution in cities. Moreover, the heavy traffic, construction of many tall buildings, and the increasing number of new factories due to the industrial development-all these are contributing to make the matter of air pollution worse and worse in the Metropolitan, whose geographical location is quite unfavorable considered from the view point of air pollution. Most homes in Seoul use briquet as fuel, while oils are used in tall buildings. The CO, $SO_2$, and smoke that come from burning of these fuels are a great threat to the health of the urban population. With the purpose of examining the influence of air pollution upon the public health, written inquiries were made upon respiratory diseases, and the carboxyhemoglobin saturation in the blood was measured to determine whether the air pollution may affect the health of the urban population. Method of Health Examination (1) Investigation of Respiratory Diseases Patients' records were examined to figure out the monthly ambulance rate of respiratory patients to the total number of patients treated. On the other hand, by using the questionnaire form approved by the Medical Research Council's Committee on Research into Chronic Bronchitis, investigators interviewed the examinees and inquired into the respiratory symptoms. (2) Measuring of Carboxyhemoglobin Saturation From the ear lobe of the examinees, with the use of the melangeur for the white blood cell counting, blood was taken, and after diluting it ten times with 0.1% $Na{2}CO_{3}$, again diulting it 20 times with 0.5% $Na_{2}\;CO_{3}$, its absorbancy was measured. The following results are obtained from the investigation. (1) It was found out that 7.7% of the total patients under treatment were suffering from upper respiratory infection, acute or chronic bronchitis, bronchial asthma, pulmonary emphysema and bronchiectasis. Of them all, patients with upper respiratory infection numbered the greatest with 4.8% and patients with acute or chronic bronchitis the next with 2.1%, and their monthly ambulance rate was high from December to February during the winter, and from April to May and from September to October during the changeable seasons. (2) The daily ambulance rate of respiratory patients, it was revealed, had a close connection with the concentration of $SO_2$ and CO in the air. (3) It was found out that men were more subject to respiratory disease than women, and both men and women were more liable to the diseases with the advancing of age. (4) People living at Choong-ku with the heavy traffic and in the industrial zones of Yeungdungpo had high frequency of respiratory symptoms. (5) Considered from the view point of occupations, high frequency was found among those without job, with jobs unknown, merchants and intdustrial workers, whose social status was rather low and traffic policemen who were always exposed to the exhaust gas of cars. As for women, the frequency was detected in the order of those from high to low, housewives who were exposed to briquet gas, women with jobs unknown, women without jobs, whose social status was low. (6) Ex-smokers rather than smokers, of both sexes, had higher frequency. As for men, heavy smokers had high frequency, while in women light smokers had rather high frequency which was presumed to be due to their average old age. (7) Men's average of carboxyhemoglobin saturation was 9.48%, while women's was 11.3%, higher than men's. (p<0.05). Age meant no difference in the case of men, but as for women, the saturation was remarkably high between the ages from 20 to 60. (8) No regional difference was detected in the carboxyhemoglobin saturation. (9) The carboxyhemoglobin saturation was found, in the case of men, in the order of office workers, traffic policemen, students, the unemployed, merchants and industrial workers, drivers; and as for women, the order was housewives, office workers, merchants and industrial workers. (10) No significant correlation was found between the carboxyhemoglobin saturation and the concentration of CO detected in kitchens, or between the carhoxyhemoglobin saturation and the passing of time after exposure to briquet gas. No difference of carboxyhemoglobin saturation was detected between smokers and non-smokers, and the degrees of smoking; only, significant negative correlation was found between the passing of time after smoking and the carboxyhemoglobin saturation. It is ture that air pollution causes or aggravates the respiratory diseases, increases the carboxyhemoglobin saturation in the blood, but what seems to be more hazardous to the health is the air polluted by the briquet gas in the kitchens and on-dol rooms rather than the atmospheric air pollution.

  • PDF

Image Retrieval Using Spacial Color Correlation and Local Texture Characteristics (칼라의 공간적 상관관계 및 국부 질감 특성을 이용한 영상검색)

  • Sung, Joong-Ki;Chun, Young-Deok;Kim, Nam-Chul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.103-114
    • /
    • 2005
  • This paper presents a content-based image retrieval (CBIR) method using the combination of color and texture features. As a color feature, a color autocorrelogram is chosen which is extracted from the hue and saturation components of a color image. As a texture feature, BDIP(block difference of inverse probabilities) and BVLC(block variation of local correlation coefficients) are chosen which are extracted from the value component. When the features are extracted, the color autocorrelogram and the BVLC are simplified in consideration of their calculation complexity. After the feature extraction, vector components of these features are efficiently quantized in consideration of their storage space. Experiments for Corel and VisTex DBs show that the proposed retrieval method yields 9.5% maximum precision gain over the method using only the color autucorrelogram and 4.0% over the BDIP-BVLC. Also, the proposed method yields 12.6%, 14.6%, and 27.9% maximum precision gains over the methods using wavelet moments, CSD, and color histogram, respectively.