• Title/Summary/Keyword: over load ratio

Search Result 229, Processing Time 0.031 seconds

Behavior of self-compacting recycled concrete filled aluminum tubular columns under concentric compressive load

  • Yasin Onuralp Ozkilic;Emrah Madenci;Walid Mansour;I.A. Sharaky;Sabry Fayed
    • Steel and Composite Structures
    • /
    • v.51 no.3
    • /
    • pp.243-260
    • /
    • 2024
  • Thirteen self-compacting recycled concrete filled aluminium tubular (SCRCFAT) columns were tested under concentric compression loads. The effects of the replacement ratio of the recycled concrete aggregate (RCA) and steel fibre (SF) reinforcement on the structural performance of the SCRCFAT columns were studied. A control specimen (C000) was cast with normal concrete without SF to be reference for comparison. Twelve columns were cast using RCA, six columns were cast using concrete incorporating 2% SF while the rest of columns were cast without SF. Failure mode, ductility, ultimate load capacity, axial deformation, ultimate strains, stress-strain response, and stiffness of the SCRCFAT columns were studied. The results showed that, the peak load of tested SCRCFAT columns incorporating 5-100 % RCA without SF reduced by 2.33-11.28 % compared to that of C000. Conversely, the peak load of tested SCRCFAT columns incorporating 5-100% RCA in addition to 2% SF increased by 21.1-40.25%, compared to C000. Consequently, the ultimate axial deformation (Δ) of column C100 (RCA=100% and SF 0%) increased by about 118.9 % compared to C000. The addition of 2% SF to the concrete mix decreased the axial deformation of SCRCFAT columns compared to those cast with 0% SF. Moreover, the stiffness of the columns cast without SF decreased as the RCA % increased. In contrast, the columns stiffness cast with 2% SF increased by 26.28-89.7 % over that of C000. Finally, a theoretical model was proposed to predict the ultimate loads tested SCRCFAT columns and the obtained theoretical results agreed well with the experimental results.

Reduction of Nitrous Oxide Emission by EGR Method on Diesel Engine (디젤엔진에서 배기가스 재순환 방법을 이용한 아산화질소의 배출률 저감)

  • Yoo, Dong-Hoon
    • Journal of Power System Engineering
    • /
    • v.19 no.3
    • /
    • pp.16-21
    • /
    • 2015
  • Nitrous oxide($N_2O$) concentration in the atmosphere has been constantly increased by the human activities with industrial growth after the industrial revolution. One of factors to increase $N_2O$ concentration in the atmosphere is the $N_2O$ emission caused by the combustion of marine fuel. Especially, a sulfur component included in marine fuel oils is known as increasing the $N_2O$ formation in diesel combustion. Form this point of view, $N_2O$ emission from a ship is not negligible. On the other hand, Exhaust gas recirculation(EGR) that have thermal, chemical and dilution effect is effective method for reducing the NOx emission. In this study, an author investigated $N_2O$ reduction by using EGR on a direct injection diesel engine. The test engine was a 4-stroke diesel engine with maximum output of 12 kW at 2600rpm, and operating condition of the engine was a fixed load of 75%. The experimental oil was a blend-fuel that were adjusted with sulfur ratio of 3.5%, and EGR ratio of 0%, 10%, 20% and 30%. In conclusion, diesel fuel that contained 3.5% sulfur component increased $SO_2$ emission in exhaust gas, and increment of EGR ratio reduced NO emission. Moreover, $N_2O$ emission was decreased as over 50% at EGR ratio of 10% and reduced 100% at EGR ratio of 30% compared with $N_2O$ emission of 0% EGR ratio.

Capacity and Power Input Performance Curves Creation of Water-cooled VRF Heat Pump for EnergyPlus (EnergyPlus 해석용 수랭식 VRF 히트펌프의 냉·난방 능력 및 소비전력 예측식 산출 기법)

  • Kim, Min-Ji;Kwon, Hyuk-Joo;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • Variable refrigerant flow (VRF) systems have recently attracted attention in many countries due to a variety of advantages over conventional system. Especially, the water-cooled VRF heat pump, including geothermal heat pump, is a system that accurately controls the flow rate of refrigerant for the improved efficiency under part load operation. This paper describe the process of generating the cooling and heating energy performance curve coefficients and performance expressions for modeling water cooled VRF system using EnergyPlus. Through this study, the process for generating performance curves can be implemented into EnergyPlus or other comparable building energy analysis tools for the long-term evaluation of heat pump under dynamic conditions.

A Study on Determining Complex Young's Modulus of Acoustic Materials (음향 재질의 복소수 모듈러스 추출에 관한 연구)

  • Kim, In-Su;Lee, Hyo-Keun;Kim, Sung-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 1991
  • Since the Complex Young's Modulus of acoustic materials is a function of frequency under a static load, a cylindrical specimen modelled by rod-like one with losses is used to determine the dynamic characteristics of materials. The specimen is excited into longitudinal vibration at its one end by shaker and at the other end, loaded by a mass corresponding to the desired static load and thus the transfer function of specimen is measured. This transfer function method is analyzed theoretically and experimentally over a frequency range of 50 Hz to 20 KHz. The analysis includes the measurability of the transfer function, the frequency range of the method and lateral motion effect.

  • PDF

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

Combustion Instability of Gas Turbine with Segmented Dynamic Thermo-Acoustic Model under Load Follow-Up (이산형 열-음향 모델을 이용한 부하 변동시 가스터빈 연소 불안정 특성)

  • JEONG, JIWOONG;HAN, JAEYOUNG;JEONG, JINHEE;YU, SANGSEOK
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.5
    • /
    • pp.538-548
    • /
    • 2018
  • The thermo-acoustic instability in the combustion process of a gas turbine is caused by the interaction of the heat release mechanism and the pressure perturbation. These acoustic vibrations cause fatigue failure of the combustor and decrease the combustion efficiency. This study is to develop a segmented dynamic thermo-acoustic model to understand combustion instability of gas turbine. Therefore, this study required a dynamic analysis rather than static analysis, and developed a segmented model that can analyze the performance of the system over time using the Matlab/Simulink. The developed model can confirm the thermo-acoustic combustion instability and exhaust gas concentration in the combustion chamber according to the equivalent ratio change, and confirm the thermo-acoustic combustion instability for the inlet temperature and the load changes. As a result, segmented dynamic thermo-acoustic model has been developed to analyze combustion instability under the operating condition.

The effect of the excessive loading and welding anisotropy on the fatigue crack propagation behavior of TMCP steel for offshore structure (해양구조물용 TMCP강의 피로균열진전거동에 미치는 용접이방성 및 과대하중의 영향)

  • ;;三澤啓志
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.82-88
    • /
    • 2000
  • The effect of the welding for the offshore structure in the TMCP steel on the fatigue crack propagation rate and crack opening-and-closure behavior was examined. The welding anisotropy of the TMCP steel and crack propagation characteristics of the excessive loading were reviewed. (1) It seemed that a heat which was generated by the welding made a compressive residual stress over the base metal, so fatigue crack propagation rate was placed lower than in case of the base metal. (20 In the base metal, an effect of the anisotropy which has an effect of fatigue crack propagation rate of the excessive load and the constant amplitude laos was not found but in the welding material case, fatigue crack propagation rate of the excessive load in the specimen of the width direction was located in the retard side as compared with a specimen rolling direction. (3) A crack opening ratio of the used TMCP stel in this study was not changed after excessive loading but a retard phenomenon of crack propagation was observed. Consequently, it was thought that all of the retard phenomenon of crack propagation did not only a cause of the crack opening-and-closure phenomenon.

  • PDF

Modifications to fire resistance ratings of steel frames based on structural configuration: A probabilistic-based approach

  • Behnam, Behrouz
    • Structural Engineering and Mechanics
    • /
    • v.77 no.5
    • /
    • pp.661-672
    • /
    • 2021
  • In this article, the role of spans number and length in fire-resistance ratings (FRRs) of fireproofed steel frames are investigated. First, over a span-lengthening scenario, two one- and three-bay frames under the ISO834 fire are examined. It is shown that the FRRs of the frames rely highly on the changes made on their span length. Second, a building designed for three spans number of three, four, and five under natural fire is investigated. The beams are designed for two load-capacity-ratios (LCRs) of optimum and ultimate. The fire curves are determined through a probabilistic-based approach. It is shown that the structural vulnerability vastly increases while the number of spans decreases. The results show that for an optimum LCR, while the five-span frame can meet the required FRR in 87% of the fire scenarios, the four- and three-span frames can meet the required FRR in only 56%, and 50% of the fire scenarios, respectively. For an ultimate LCR, the five-, four- and three-span frames can meet the required FRR in 81%, 50%, and 37.5% of the fire scenarios, respectively. Functional solutions are then proposed to resolve the insufficiencies in the results and to rectify the application of the standard-based FRRs in the cases studied. The study here highlights how employing current standard-based FRRs can endanger structural safety if they are not connected to structural characteristics; a crucial hint specifically for the structural engineering community who may be not well familiar with the fundamentals of performance-based approaches.

Measurement of K0 and K'0 during loading and unloading of loose sand

  • Shay Nachum;Mark Talesnick;Sam Frydman
    • Geomechanics and Engineering
    • /
    • v.32 no.1
    • /
    • pp.97-110
    • /
    • 2023
  • The coefficient of lateral earth pressure at rest in loose sand during virgin loading, K0 , and during unloading, K'0 , have been determined from laterally confined load-unload tests. The tests included measurement of lateral pressure with null pressure gauges, side wall friction with newly designed friction meters and applied pressure and base pressure with load cells. The importance of accounting for side-wall friction when evaluating the distribution of vertical pressure over the height of the soil specimen was demonstrated. Relatively uniform friction was observed during loading, but this was not the case during unloading unless friction reduction measures were employed. While the measured value of K0 was found to be close to, if slightly higher than the value commonly estimated on the basis of friction angle, φ', the ratio of K'0 to K0 was found to reasonably fit an expression of the form K'0/K0 = 1 + C·log(OCR), with C equal to 1 in the present tests.

Risk Assessment of Strong Wind over Industrial Facilities in Shipyards (조선소 시설물의 강풍 위험 평가)

  • Lee, Sung-Su;Kim, Hak-Sun;Lee, Young-Kyu;Shim, Kyu-Cheoul
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.4
    • /
    • pp.21-28
    • /
    • 2009
  • Most of domestic shipyards are located at coastal regions which are affected by typhoons nearly every year. For effectiveness of shipbuilding, shipyards contain many facilities which are light-weighted and affected dominantly by wind. In the present paper, we analyze various wind fields over a shipyard including surrounding topology and structures to evaluate the structural safety of the facilities posed in the strong wind. Extreme wind speed for a study region was estimated by typhoon Monte Carlo simulation and then used for inlet wind speed for CFD analysis for wind load on the facilities. Considering geometrical wind effects, we assess the surface pressure of the elements as the pressure factor, the ratio of surface pressure to dynamic pressure. The results show that the simulated wind speed is greater than the design wind speed for the some facilities because of the shipyard's geometry. It also shows that surrounding topography in coastal area is needed to be considered and adjustment for design wind speed at wind load standard application is necessary for mooring ship and industry facilities.