• 제목/요약/키워드: over current characteristics

검색결과 1,157건 처리시간 0.031초

Conceptual design and fabrication test of the HTS magnets for a 500 W-class superconducting DC rotating machine under 77 K

  • Choi, J.;Kim, S.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.35-38
    • /
    • 2021
  • Conventional direct current (DC) rotating machines are usually used for crane and press machine using high torque in metal and steel industries, because of a constant output power along variable rotating speed. A general DC motor with permanent field magnets could not increase a magnetic flux density at a gap between armature coils and field magnets. However, a superconducting DC motor has field magnets composed with high temperature superconducting (HTS) coils and it could increase the magnetic flux density at the gap to over 10 times than those of a general DC motor by control the excitation current into HTS coils. The superconducting DC motor could be operated with extremely high torque and constant output power at a low rotational speed. In this paper, a 500 W superconducting DC rotating machine was conceptually designed with a LN2 (Liquid Nitrogen) cooling method and the operation characteristics results of HTS field magnets were presented. The two no-insulation HTS magnets for a 500 W superconducting DC rotating machine were fabricated. The excitation current for the HTS magnets could be controlled from 0 to 40 A. This test results will be available to design large-sized HTS magnets for a number of hundred kW class superconducting DC rotating machine under LN2 cooling system.

Fabrication and Test of Multiple HTS Wire with Transposition for HTS Power Transformer

  • Kim, Woo-Seok;Park, Chan;Choi, Kyeong-Dal
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.34-37
    • /
    • 2008
  • According to the recent design of an HTS (High Temperature Superconducting) power transformer whose capacity is hundreds MVA, the rated current values of the low voltage side are generally over thousands amps. Considering the performance of the recent HTS wires, it is inevitable to use several HTS wires in parallel for large rated current. Lots of stacked HTS wires were fabricated and tested so far, and the results have showed that we have to transpose each wire in order to reduce the AC losses as well as to increase the current capacity. But many development programs about HTS transformers reveal that the transposition of the several wires during the winding process is quite difficult not only in case of the layer windings but also in case of the pancake type ones. So, we need transposed multiple HTS wire which we can handle like single wire or cable for the HTS windings of large capacity power transformer. We fabricated several kinds of samples of multiple HTS wire with transposition to apply it to the HTS windings of power transformer. The electrical characteristics such as critical currents or AC losses are analyzed by experiments in case by case. Finally we present the best design of a multiple HTS wire for power transformer.

수치모델링 실험을 통한 서해 천수만의 조류와 조석잔차류 특성 (Characteristics of Tidal Current and Tidal Residual Current in the Chunsu Bay, Yellow Sea, Korea based on Numerical Modeling Experiments)

  • 정광영;노영재;김백진
    • 한국해안·해양공학회논문집
    • /
    • 제25권4호
    • /
    • pp.207-218
    • /
    • 2013
  • 수치 모델링 실험을 활용하여 서해 천수만의 해수 유동과 그 변화를 이해하기 위한 연구를 수행했다. 모델링 실험 결과에 대한 검증을 위해 관측 자료의 조위와 조류 각각 4대 분조의 진폭과 위상을 이용하여 스킬 분석을 실시했다. 그 결과 스킬 점수는 대부분 90%가 넘는 것으로 보아 수치 모델링 실험 결과는 관측된 조위와 조류가 양호하게 일치하는 것으로 나타났다. 천수만의 조석파는 만 입구에서 안쪽으로 진행되며 북부로 갈수록 조차는 점차 증가했다. 조석파가 북부까지 도달하는데 약 10~30분의 시간이 소요되었다. 남부에서 조석파는 반시계 방향으로 회전하는 특성을 보였다. 조류는 해저 지형을 따라 남-북 방향으로 흘렀으며, 장축의 각도는 등수심선과 나란히 나타났다. 조류타원의 단축이 장축의 10% 이하로 왕복성 조류의 특성을 보였다. 수심과 해안선 등 지형적 요인에 의해 좌우되는 조석잔차류의 크기는 1~30 cm/sec의 범위를 보였고, 남쪽 수로에서 컸으며 만의 북부에서는 작았다. 조석잔차류로부터 유도된 상대와도를 통해 수 백 m에서 수 km 크기로 시계/반시계 방향으로 회전하는 와류를 확인했고, 죽도 주변에서 2쌍, 남부에서 형성된 3~4쌍의 강한 와류 특성을 파악했다.

산화된 다공질 폴리실리콘 전계방출 소자의 픽셀별 구동 및 특성 (A unit pixel drive and field emission characteristics of oxidized porous polysilicon field emission display)

  • 유성원;김진의;최시영
    • 대한전자공학회논문지SD
    • /
    • 제44권8호
    • /
    • pp.8-15
    • /
    • 2007
  • 본 논문에서는 산화된 다공질 폴리실리콘을 이용하여 전계 방출 소자를 제작하여, 각각의 픽셀에 따른 전기적 특성과 형광체의 발광 특성을 조사하였다. 실제 대면적 디스플레이 소자에 적용하기 위해서 PM 방식을 이용해서 소자를 픽셀별로 동작하였고, 상부금속 전극의 어레이에 따른 두께와 폭의 공정조건을 확립하였다. 산화된 다공질 폴리실리콘의 미세 구조를 분석하고, 각각의 픽셀에 따른 전계방출 특성을 조사해 보았다. 상부금속 전극의 두께와 폭에 따른 전자방출 특성을 조사해 본 결과 Ti/pt(2nm/7nm)가 가장 적절한 두께라는 것을 확인 할 수 있었고, 2.5 mm 이상 폭에서 전자방출 효율이 증가하는 모습을 확인 할 수 있었다. 각 픽셀에 따른 소자의 전기적 특성은 픽셀마다 조금씩의 차이는 있지만 거의 동일한 누설 전류와 방출 전류가 나타남을 확인할 수 있었고, 동일한 크기의 효율도 관찰할 수 있었다. 누설 전류와 방출 전류는 시간이 증가함에 따라 감소하는 모습이 나타나긴 하였으나, 모든 픽셀이 거의 동일하게 감소하였다. 각각의 픽셀에 따른 휘도는 큰 차이가 없음을 확인할 수 있었고, 20 V에서 $700cd/m^2$ 이상의 높은 휘도를 나타내었으므로 실제 디스플레이 소자로도 응용이 가능할 것이다.

경기만 남부에 발달된 해저지형의 형태적 특징 및 해사채취에 의한 변화 (Morphological Features of Bedforms and their Changes due to Marine Sand Mining in Southern Gyeonggi Bay)

  • 금병철;신동혁;정섬규;장석;장남도;오재경
    • Ocean and Polar Research
    • /
    • 제32권4호
    • /
    • pp.337-350
    • /
    • 2010
  • This study conducted sedimentological and geophysical surveys for 3 years (2006-2008) in southern Gyeonggi Bay, Korea to elucidate temporal changes in subaqueous dune morphology on a sand ridge trending northeast to southwest that has been excavated by marine sand mining. The sand ridge (~20 m in height, ~2 km in width and 3~4 km in length) has a steep slope on the NW side and a gentle slope on the SE side, creating an asymmetric profile. Large (10~100 m in length) and very large (>100 m in length) dunes occurring on the SE side of the ridge show a northeastward asymmetrical shape, whereas dunes on the NW side destroyed by marine sand mining display a southwestward asymmetry. The comparison between Flemming (1988)'s correlation and the height-length correlation of this study indicates that tidal current and availability of sand sediment are major controlling factors to the development and maintenance of dunes. Depth and sedimentary characteristics (grain size) are not likely to be major controlling factors, but indirectly influence dune growth by hydrological and sedimentary processes. The length and the height of dunes decrease toward the southeastern trough away from the crest of the ridge. These features result from the decrease of tidal current and sediment availability. The length and the height of dunes on the southeast side decrease gradually over time. This is a result of the interaction between tidal current and the decrease in sediment availability due to sediment extraction by marine sand mining. Marine sand mining has destroyed the dunes directly, causing irregular shapes of shorter length and lower height. The coarse fraction of suspended sediments is transported and deposited very close to the sand pit. By contrast, relatively fine sediments are transported by the tidal current and deposited over a wide range by the settling-lag effect, resulting in a decrease of sediment grain size in the area where suspended sediments are deposited. In addition, marine sand mining, decreases the height of dunes. Therefore, morphological and sedimentological characteristics of dunes around the sand pits will be significantly changed by future sand mining activities.

전류모드 CMOS에 의한 다치 가산기 및 승산기의 구현 (Implementation of Multiple-Valued Adder and Multiplier Using Current-Mode CMOS)

  • 성현경
    • 정보처리학회논문지A
    • /
    • 제11A권2호
    • /
    • pp.115-122
    • /
    • 2004
  • 본 논문에서는 전류모드 CMOS를 사용하여 다치 가산기 및 다치 승산기를 구현하였으며, 먼저 효과적인 집적회로 설계 이용성을 갖는 전류모드 CMOS를 사용하여 3치 T-게이트와 4치 T-게이트를 구현하였다. 구현된 다치 T-게이트를 조합하여 유한체 $GF(3^2)$의 2변수 3치 가산표와 승산표를 실현하는 회로를 구현하였으며, 이들 다치 T-게이트를 사용하여 유한체 $GF(4^2)$의 2변수 4치 가산표와 승산표를 실현하는 회로를 구현하였다. 또한, Spice 시뮬레이션을 통하여 이 회로들에 대한 동자특성을 보였다. 다치 가산기 및 승산기들은 $1.5\mutextrm{m}$ CMOS 표준 기술의 MOSFET 모델 LEVEL 3을 사용하였고, 단위전류는 $15\mutextrm{A}$로 하였으며, 전원전압은 3.3V를 사용하였다. 본 논문에서 구현한 전류모드 CMOS의 3치 가산기와 승산기, 4치 가산기와 승산기는 일정한 회선경로 선택의 규칙성, 간단성, 셀 배열에 의한 모듈성의 이점을 가지며 특히 차수 m이 증가하는 유한체의 두 다항식의 가산 및 승산에서 확장성을 가지므로 VLSI화 실현에 적합한 것으로 생각된다.

저기압하의 아르곤 가스의 RF 글로우 방전특성 (RF Glow Discharge Characteristics of Argon at Low Gas Pressure)

  • 곽동주;김두환;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1382-1384
    • /
    • 1995
  • In order to study the structure of RF glow discharge driven at 13.56MHz in argon, the discharge voltage, current and phase shift between them will be measured over a wide range of discharge parameters(gas pressure between 1mTorr and 50mTorr with discharge power between 20mW and 200W). In this paper, the dc glow discharge characteristics and plasma parameters of both FTS and CPMS systems are studied experimentally. It is found that for CPMS system discharge is stablized under wider ranges of magnetic field and pressure than for FTS system. The plasma density and electron temperature of the plasma for these two systems are in the range of $10^{10}{\sim}7{\times}10^{11}[cm^{-3}]$ and $3.5{\sim}6.5$[eV], respectively.

  • PDF

고조파 성분이 포함된 전압 불평형 운전시 유도전동기의 동작 특성 해석 (Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage with Harmonics Components)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.134-140
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are usually balanced and connected to three power systems. However, in the user power distribution systems, partial loads are single & three phase and unbalanced, generating voltage unbalance by the impedance mismatching. Voltage unbalance has detrimental effects on three-phase induction motors, including over heating, line-current unbalance, derating, torque pulsation, low efficiency, etc. This paper presents a scheme on operation states of a three-phase induction motor under the unbalanced voltages with harmonics components. Three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting not only fundamental but also harmonics components. Harmonic components at the voltage unbalanced factor(VUF) of the three-phase source voltages can then be examined the different values of VUF on machine's operation characteristics.

이등용 안정기의 전기적 특성 및 성능 분석 (Analysis of Electrical Characteristics and Performance of Ballast for Dual Lamps)

  • 박용산;지평식
    • 전기학회논문지P
    • /
    • 제62권2호
    • /
    • pp.79-83
    • /
    • 2013
  • An electronic ballast and magnetic ballast are two major types of ballasts used in HID(High Intensity Discharge) lamp. Compared with magnetic ballasts which can last for over 30 years and are recyclable at the end of their long lifetime, electronic ballasts have very short lifetimes due to the use of the electronic devices. In this paper, we developed a magnetic ballast for dual lamps and analyzed electrical characteristics and efficiency. As the experimental results, we confirm that the magnetic ballast for dual lamps makes it possible to effectively reduce current, active and reactive powers than conventional ballast.

전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load)

  • 이상호;오홍석
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF