• Title/Summary/Keyword: outflow patterns

Search Result 46, Processing Time 0.023 seconds

The Enlargement of EU and the Flows of Direct Investment within EU (유립연합 형성과 역내 직접투자 흐름)

  • Moon, Nam-Cheol
    • Journal of the Korean association of regional geographers
    • /
    • v.10 no.2
    • /
    • pp.371-388
    • /
    • 2004
  • EU is enlarging geographically by the process of expansion and is intensifying the economic bloc by the formation of European Union and European Monetary Union. This situation increases the direct investment in the intra-EU members and changes the intra-EU flows. First, EU is formed by the economic geographical space of the North and the South with a differentiation of economic factors and the degree of economic development. The North played a leading role for an augmentation of the intra-EU direct investment after the formation of EU. Second, the manufacturing industry of the intra-EU direct investment by industry was increased remarkably. In the intra-EU direct investment flow by region and industry, the South made relatively an outflow of the service industry and an inflow of the manufacturing industry. But the North made an outflow of the manufacturing industry and an inflow of the service industry. Third, in the intra-EU direct investment flows by manufacturing industry, the North concentrated in the petro-chemistry, metal-machinery and agro-food industry, however, the South which have relatively weak competitiveness compared to the North tends to show balanced investment patterns in all industries.

  • PDF

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.

Differences of Zooplankton Development Along a Lake and a River Stretch of the River Spree (Germany) (스프리 강 (독일) 내의 호수와 강 구획에서의 동물플랑크톤 성장의 차이)

  • Joo, Gea-Jae;Walz, Norbert;Kim, Hyun-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.197-205
    • /
    • 2000
  • Factors most strongly related to zooplankton growth rates were studied along a lake and a river stretch in the middle part of the lowland River Spree. The study was conducted at the lake inflow (S1), the lake outflow (S2), and at the end of a 21 km stretch of the outflow (S3) from March to November of 1999. Total zooplankton biomass increased significantly at S2 and then sharply decreased at S3. The abundance of microzooplankton (rotifers and nauplii) was strongly higher than macrozooplankton (cladocerans and copepodids) at all station. However, macrozooplankton biomass (${\mu}$g dw 1$^{-1}$) was similar or much higher than microzooplankton biomass. Large-bodied cladocerans (Daphnia cucullata) dominated at S2 while small-bodied cladocerans (Bosmina longirostris) dominated at S1 and S3. Patterns in growth rates (r$_{t}$ in d$^{-1}$ of the major zooplankton community were greatly different between S1 and S2 (lake stretch) and between S2 and S3 (river stretch). In the lake, growth rates generally were positive, while values of growth rates were negative in the river stretch. Among the environmental variables considered, partial retention time (PRT, d$^{-1}$) seemed to play the most important role in determining characteristics of the zooplankton community structure in the middle part of River Spree.

  • PDF

Observed and Simulated Seasonal Salinity in The Tropical Atlantic ocean, and its Relationship with Freshwater (관측과 모델에서 얻어진 열대 대서양에서의 계절별 염분 분포 및 담수 효과)

  • YOO, JUNG-MOON
    • 한국해양학회지
    • /
    • v.27 no.4
    • /
    • pp.290-302
    • /
    • 1992
  • Seasonal variations of salinity in the upper 500 m of the tropical Atlantic Ocean are examined, based on both climatological seasonal salinity observations and numerical simulations with hydrological forcing. The seasonal cycle of sea surface salinity has strong seasonal variations caused by shifts of the freshwater surplus zone (i.e. the intertropical convergence zone) and the river outflow. The climatological seasonal salinity in this analysis concurs with other independent observations described by Default (1981) and Levitus (1982), but provides more consistent patterns with temperature structure. The effect of salinity on density below 100 m depth in the tropical Atlantic is negligible compared to tat of temperature, which in the mixed layer salinity affects density significantly. The systematic difference between observed and simulated salinity is found to be the fact that the simulated salinity is higher in the subtropics than the observed salinity, and possible sources about the difference are also discussed.

  • PDF

Analysis of Sectoral Energy Use Pattern with Energy Input-Output Approach (에너지산업연관분석을 이용한 산업별 에너지 사용 pattern 분석)

  • Chung, Whan-Sam;Tohno, Susumu;Shim, Sang-Yul
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2008
  • Approaching to the era of high energy price and energy sources scarcity, the demand for governmental intervention to mitigate the short-term shocks is highly increasing. When any energy policy is implemented, double-side effects would be derived. To begin with positive aspect, by decreasing energy import, unnecessary currency outflow can be prevented and the resultant saved money will be appropriately allocated. Furthermore, industrial competitiveness will be assured by reducing use of expensive energy. On the contrary, inappropriate energy saving policy may lead to unexpected negative effects that would hinder improvement in productivity due to indiscreet replacing energy by equipments. In order to enhance effectiveness of energy policy, efforts should be made in advance to understand the energy use pattern of each industry sector which composes the economy. Therefore, in this study, an energy input-output method, one of the macroscopic approaches, is applied to analyze energy use patterns of each industry sector in Korea. Using this method, a quantitative assessment is performed to obtain the energy use intensity and the amount of energy uses with respect to energy types.

Investigation of amount of the Air Flow through a Natural Ventilator in the Subway System (지하철 자연환기구 공기 이동량 조사)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun;Kim, Shin-Do;Lee, Kyoung-Bin;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1480-1486
    • /
    • 2011
  • After installation of platform screen door (PSD) in subway stations, particulate matters (PMs), which are originally ventilated through the platform, are accumulated inside the tunnel of the subway system. It deteriorates an air quality inside the tunnel. To ventilate the accumulated PMs inside the tunnel, the natural ventilator which are located inside the tunnel (namely, tunnel ventilation system) are used as only one circulation system. In addition, the installation of PSD can affect to the aerodynamic variations inside the tunnel, since the PSD system was not considered factor when the tunnel ventilation system was designed. However, the researches about the tunnel ventilation system have not been adequate. Therefore, this study is carried out with two objectives: 1) to measure the velocity of air current by the train-induced wind, when the train passes through the tunnel, and 2) to investigate the typical patterns of air current by quantitatively evaluating the characteristics of inflow/outflow of air current which passes through the natural ventilation system. This study can suggest the basic standard to newly design the tunnel of the subway system as well as the ventilation system.

  • PDF

A Study on Constructing of Security Monitoring Schema based on Darknet Traffic (다크넷 트래픽을 활용한 보안관제 체계 구축에 관한 연구)

  • Park, Si-Jang;Kim, Chul-Won
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1841-1848
    • /
    • 2013
  • In this paper, the plans for improvement of real-time security monitoring accuracy and expansion of control region were investigated through comprehensive and systematic collection and analysis of the anomalous activities that inflow and outflow in the network on a large scale in order to overcome the existing security monitoring system based on stylized detection patterns which could correspond to only very limited cyber attacks. This study established an anomaly observation system to collect, store and analyze a diverse infringement threat information flowing into the darknet network, and presented the information classification system of cyber threats, unknown anomalies and high-risk anomalous activities through the statistics based trend analysis of hacking. If this security monitoring system utilizing darknet traffic as presented in the study is applied, it was indicated that detection of all infringement threats was increased by 12.6 percent compared with conventional case and 120 kinds of new type and varietal attacks that could not be detected in the past were detected.

Patterns of Migration in the Busan Metropolitan Area(II) : Household Characteristics and Migration Selectivity (부산 대도시권의 인구이동(II) : 이동 가구 특성과 선택성)

  • Choi, Eun-Young;Koo, Dong-Hoe;Joe, Soon-Kee
    • Journal of the Korean association of regional geographers
    • /
    • v.16 no.2
    • /
    • pp.123-136
    • /
    • 2010
  • To grasp the migration characteristics in the Busan Metropolitan Area (BMA), this study analyzed household characteristics and migration selectivity. The major findings of the study are as follows: first, young (especially 25 to 34 years of age) and single person households have greater propensity to migrate out from BMA, and their home ownership rate is low. These trends are much stronger in households that migrate out towards the Seoul Metropolitan Area from Busan. Second, age and educational selectivity of migration is evident. The characteristics of movers are quite different from those of stayers at Busan. Young people are more likely to migrate out of Busan, and higher levels of education are deeply associated with higher mobility. Through analyzing four high schools in Busan, it is acknowledged that most honor students entered 4-year universities in Seoul. The outflow of highly educated young people may induce the brain drain. Busan is undergoing both population decline and the problems caused by the brain drain.

  • PDF

A follow-up study of electrocardiographic changes following the corrective surgery for atrial septal defect in adult (성인에 있어서 심방중격결손증 교정수술후 심전도의 경시적 변화에 관한 연구)

  • Lee, Young-Thak;Chae, Hurn;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.241-250
    • /
    • 1987
  • We scrutinized the preoperative electrocardiographic and hemodynamic findings in adult atrial septal defects older than 15 years, and then followed up the postoperative electrocardiographic changes sequentially. In preoperative electrocardiographs, the mean PR interval [0.17 sec] was prolonged than normal adults [M;0.13,F;0.15], and the mean QRS axis [93.1*] was deviated to rightward than normal [M;63.7*,F;64.4*], and 122 cases of all 159 patients [77.8%] were in RAD quadrant. The QRS morphology was classified into three groups; a] crista supraventricularis hypertrophy, 25 cases, b] right ventricular outflow tract hypertrophy, 89 cases, c] right ventricular hypertrophy, 44 cases, and normal rs pattern, 1 case. Comparing the QP/QS, Pp/Ps, Rp/Rs in these three groups, Qp/Qs increased a] 2.65 to b] 2.97 and decreased b] 2.97 to c] 2.55, Pp/Ps increased a] 0.27 to b] 0.35 to c] 0.44, and Rp/Rs increased a] 0.1 to b] 0.14 to c] 0.2. In comparing the atrial fibrillation with sinus rhythm, the patient`s mean age was increased [26.4 to 45.7], the mean Qp/Qs was decreased [2.97 to 2.7], the mean Pp/Ps was increased [0.35 to 0.46], the mean Rp/Rs increased [0.14 to 0.2], and the QRS morphology was RVOT hypertrophy;7 cases, RVH;2 cases in all 11 cases. Therefore, the atrial fibrillation was appeared in progressed status. Increasing the mean pulmonary arterial pressure, size of the R` wave in Vl lead increased, and the QRS morphology tended to become severe patterns. Postoperatively, the PR interval shortened and QRS axis tended to normal axis quadrant, and size of R` wave decreased sequentially, atrial fibrillation disappeared in 4 cases. Conclusively, by use of the conventional surface electrocardiography, we could anticipate the hemodynamic changes and the prognosis at outpatient department.

  • PDF

Modified Fontan Procedure for Single or Dominant Right Ventricle (우세우심실 또는 우단심실증에서의 변형 Fontan 수술)

  • 백완기
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.310-321
    • /
    • 1991
  • Between April 1986 and September 1990, 34 patients with a single or dominant right ventricle underwent modified Fontan procedure for definite palliation in Seoul National University Children`s Hospital. Their age at operation ranged from 8 months to 14 years [Mean 5.5 years]. The ventricular chamber was solitary and of indeterminate trabecular pattern in 6 patients. 28 patients had posteriorly located rudimentary chamber, all of which were trabecular pouches having no communication with outlet septum. The patterns of atrioventricular connection were common inlet[9], double inlet [11], left atrioventricular valve atresia [12] and right atrioventricular valve atresia with L-loop [2]. Pulmonary outflow tracts were atretic in 7 patients and stenotic in 26 patients. Major associated anomalies included anomalous systemic venous drainage [15], dextrocardia [12] and total anomalous pulmonary venous connection[3]. Shunt operations were previously performed in 13 patients and pulmonary artery banding and atrial septectomy in 1 patients. Surgery included intraatrial baffling in 26 patients, bidirectional cavopulmonary shunt in 13 patients, atrioventricular valve obliteration in 3 patients and atrioventricular valve replacement in 3 patients. Central venous pressure measured postoperatively at intensive care unit ranged from 18cm H2O to 28cm H2O [mean 23.2cm H2O]. Hospital mortality was 35.3% [12/34], all died out of low output syndrome. Suspected causes of low output syndrome include ventricular dysfunction [8], hypoplastic or tortuous pulmonary artery [2] and elevated pulmonary vascular resistance [2]. 19 patients had 31 major complications including low output syndrome [18], arrhythmia [4], acute renal failure [3] and respiratory failure [3]. Mortality rate was significantly higher in the groups receiving intraatrial baffling and AV valve replacement respectively [p<0.05]. 20 patients were followed up postoperatively with the mean follow-up period 15.0$\pm$11.6 months. There were no late death and follow-up catheterization was performed in 10 patients. Mean right atrial pressure was 15.4$\pm$6.8mmHg and ventricular contraction was reasonable in all but one case. Thus, Fontan principle can be applied successfully to all the patients with complex cardiac anomaly of single ventricle variety and better results can be anticipated with judicious selection of patient and improvement of postoperative care.

  • PDF