• Title/Summary/Keyword: outdoor temperature

Search Result 797, Processing Time 0.026 seconds

Development of Weather Forecast Models for a Short-term Building Load Prediction (건물의 단기부하 예측을 위한 기상예측 모델 개발)

  • Jeon, Byung-Ki;Lee, Kyung-Ho;Kim, Eui-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • In this work, we propose weather prediction models to estimate hourly outdoor temperatures and solar irradiance in the next day using forecasting information. Hourly weather data predicted by the proposed models are useful for setting system operating strategies for the next day. The outside temperature prediction model considers 3-hourly temperatures forecasted by Korea Meteorological Administration. Hourly data are obtained by a simple interpolation scheme. The solar irradiance prediction is achieved by constructing a dataset with the observed cloudiness and correspondent solar irradiance during the last two weeks and then by matching the forecasted cloud factor for the next day with the solar irradiance values in the dataset. To verify the usefulness of the weather prediction models in predicting a short-term building load, the predicted data are inputted to a TRNSYS building model, and results are compared with a reference case. Results show that the test case can meet the acceptance error level defined by the ASHRAE guideline showing 8.8% in CVRMSE in spite of some inaccurate predictions for hourly weather data.

Comparative analysis on environment control systems for glasshouses and plastic houses (유리온실과 플라스틱 온실의 환경조절시스템 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk;Yu, In-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.3
    • /
    • pp.251-258
    • /
    • 2014
  • In order to set up the basic environmental control systems which the new concept greenhouses have to equip, greenhouse characteristics, environmental management and control systems in domestic glasshouses and plastic houses were investigated and analyzed comparatively. Survey results on the width, length, eaves height, and the number of spans etc. showed that glasshouses were bigger than plastic houses significantly. New concept greenhouses claim to be plastic houses, but it will be reasonable to follow the specifications of the glasshouse. Specifications to be applied to new concept greenhouses were proposed as follows; hot water heating systems, aluminum screens as the thermal curtain, evaporative cooling systems, roof vents on the ridge, circulation fans, $CO_2$ enrichment, hydroponic systems, and automatic irrigation control systems. Environmental measurement systems for the indoor and outdoor temperature, humidity, light, wind speed and indoor $CO_2$ concentration have to be fully equipped. The automatic control system has to be as a complex environmental control system, not a single item control system. Also, for stable dissemination, domestically producing complete greenhouse control system should be made as soon as possible.

An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating (PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구)

  • Chang, Min;Jung, Dong Il;Jung, Jong Ho;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

Simulation Study on the Performance Characteristics of a $CO_2$ Cooling System with an Expander (팽창기를 적용한 이산화탄소 냉방시스템의 성능특성에 관한 해석적 연구)

  • Cho, Hong-Hyun;Baek, Chang-Hyun;Ryu, Chang-Gi;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.630-639
    • /
    • 2007
  • A $CO_2$ cycle shows large throttling loss during the expansion process. The application of an expander into the $CO_2$ cycle can reduce the throttling loss and then improve system performance. In this study, the performance of a transcritical $CO_2$ cycle with an expander was analytically investigated in order to improve the cooling performance of the system. The expander was applied to the single-stage and two-stage compression cycles. The performance was analyzed with the variations of compressor frequency, outdoor temperature, and expander efficiency. The single-stage and two-stage compression cycles with the expander showed COP improvement of 25% and 32%, respectively, over the single-stage cycle with an EEV.

Theoretical Review and Experiment on Applicability of Double Skin Facade Ventilated by Fans (팬을 부착한 이중외피의 이론적 검토 및 적용성에 대한 실험 연구)

  • Lim, Ji-Hye;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.605-613
    • /
    • 2010
  • Double skin facade(DSF) ventilated by fans consists of a normal external and an internal envelope. In this glass layer, the installed fan replaces an air inlet for the control of air flow through the cavity. The purpose of this paper is to investigate physical theory and to analyze the applicability of fans installed in a DSF. The experiment was conducted in 2 rooms. One room has a DSF with installed fans and the other one has a typical window. The room ventilated through a DSF which fans are installed was always kept warmer than the other room, ventilated directly from the outdoors. The average increase of the supplied air temperature through the DSF ventilated by fans was $6.54^{\circ}C$ at 78CMH, $6.2^{\circ}C$ at 95CMH, and $3.7^{\circ}C$ at 120CMH. As a result, the DSF with installed fans was appropriate for installation in rooms. It supplies outdoor fresh air heated through a cavity and ventilates a constant air volume.

Development of Design for Heating Vest with Detachable Heating Device (발열체 탈부착형 발열조끼의 디자인 개발)

  • Lee, Jooeun;Lee, Byunghong
    • Journal of Fashion Business
    • /
    • v.18 no.5
    • /
    • pp.82-98
    • /
    • 2014
  • The influence from the increased income and aging society has amplified the interest in the well-being trend and health. People tend to enjoy sports and outdoor life. The development of smart clothing containing heating function to help maintain body temperature has been actively researched after the mid 2000s. However, the domestic study on heating clothing is severely limited. Practical study on designing heating clothing which can be commercialized is needed. The purpose of this study is to develop a commercialized detachable heating vest design through collaboration with a heating vest manufacturer. The results of this study are as follows: 1) Conducted the interview with manufacturer and a demand survey with consumers in order to develop the heating vest design. 2) Developed heating vest design that reflected the wants in the demand survey and sketched the prototype of detachable heating vest. 3) Made a sample of the heating vest and tested the wearability to illustrate the result of this study. Overall, the wearing test result showed high satisfaction for both gender.

The Analysis of Surface Degradation Mechanism on PRP(epoxy/glass fiber) by Corona Charging Properties (코로나 대전 특성을 이용한 FRP의 표면 열화메커니즘의 해석)

  • Lee, Baek-Su;Im, Gyeong-Beom;Jeong, Ui-Nam;Park, Jong-Gwan;Lee, Deok-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.373-378
    • /
    • 1999
  • In order to analyse the degradation mechanism of polymer materials for outdoor condition, FRP laminate was exposed to high temperature and ultraviolet rays. Then, thedegradation process was evaluated by comparing contact angle, surface potential decay, and polarity effect respectively. Especially, the analysis of surface degradation phenomena by corona charging method showed the exact correlation with the result of chemical properties. Therefore we can confirm that the application of corona charging method on the identification of degradation process is very useful. If this method is usedin degradation studies on the polymer surface, it will be more effective on the surface analysis of polymer insulators. With corona charging method and chemical spectrum analysis, it was possible concretely to define degradation process on the polymer surface exposed at the situation of different environmental conditions.

  • PDF

Robust Design of Pantograph Panhead Sections Considering Aerodynamic Stability and Noise (유동안정성 및 유동소음을 고려한 판토그라프 팬헤드 단면의 강건설계)

  • 조운기;이종수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1235-1241
    • /
    • 2001
  • Pantograph design process must be considered in terms of stability of aerodynamics and reduction of aeroacoustics. Furthermore Pantograph needs to be insensible to severe circumstance condition like typhoon, tunnel, a change of season. In this paper, robust design of panhead sections is conducted based on the Taguchi's design of experiment method. In the aeroacoustic noise analysis, an acoustic analogy using the Ffowcs Williams and Hawkings (FW-H) equation is used to calculate the flow induced sound pressure level. From the near-field CFD analysis data, the far-field noise is predicted at the positions of 25m away from panhead contact strips. Based on aerodynamic (CFD) and aeroacoustic (FW-H) analysis data, the optimal sizing and positioning ofpanhead elements are determined using robust design optimization method. Design parameters such as thickness, length and radius are controllable factors, while outdoor air temperature and atmospheric pressure are considered as uncontrollable factors in the context of Taguchi's approach. A number of CFD simulation and aeroacoustic analysis are performed based on orthogonal arrays. Using a parameter design procedure associated with signal-to-noise (SIN) ratio and sensitivity analysis, an optimal level of design parameters are extracted to minimize the disconnection ratio between contact strips and catenary system, and reduce the far-field aeroacoustic noise.

  • PDF

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

A continuous-flow and on-site mesocosm for ocean acidification experiments on benthic organisms

  • Kim, Ju-Hyoung;Kang, Eun Ju;Kim, Keunyong;Kim, Kwang Young
    • ALGAE
    • /
    • v.33 no.4
    • /
    • pp.359-366
    • /
    • 2018
  • Mesocosm experiments conducted for ecological purposes have become increasingly popular because they can provide a holistic understanding of the biological complexities associated with natural systems. This paper describes a new outdoor mesocosm designed for $CO_2$ perturbation experiments of benthos. Manipulated the carbonate chemistry in a continuous flow-through system can be parallelized with diurnal changes, while irradiance, temperature, and nutrients can vary according to the local environment. A target hydrogen ion activity (pH) of seawater was sufficiently stabilized and maintained within 4 h after dilution, which was initiated by the ratio of $CO_2$-saturated seawater to ambient seawater. Specifically, pH and $CO_2$ partial pressure ($pCO_2$) levels gradually varied from 8.05-7.28 and $375-2,691{\mu}atm$, respectively, over a range of dilution ratios. This mesocosm can successfully manipulate the pH and $pCO_2$ of seawater, and it demonstrates suitability for ocean acidification experiments on benthic communities.