• Title/Summary/Keyword: outdoor exposure testing

Search Result 13, Processing Time 0.025 seconds

A Study on Changes of Physical Properties of Rooftop Exposed Waterproofing PVC Sheet based on Longterm Outdoor Exposure Testing with Bearings (North, South) (옥상 노출방수용 PVC 방수시트의 방위별(남, 북) 장기옥외폭로에 따른 물성 변화 연구)

  • An, Ki-Won;Moon, You-Seok;Kim, Chun-Hag;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.147-148
    • /
    • 2015
  • Exposed type waterproofing PVC sheets installed on structure rooftops are subject to changes in physical properties after longterm exposure to sunlight. Particularly when consideration the rotational movement of sunlight over the day through the course of the sun rising from the east and setting in the west, in the case of flat roofs the amount of UV ray the the surface of the PVC waterproofing sheet receives may be even throughout, but in cases of slanted rooftops the sunlight exposure may be uneven across the surface. In this regard, this study examines the effect uneven sunlight exposure on the exposed type waterproofing PVC sheets installed on slanted rooftops.

  • PDF

Surface Appearance of Galvanized Steel with Outdoor Exposure Testing in Korea for 36 Months (36개월간 국내 옥외폭로시험에 따른 아연도강의 표면외관 변화)

  • Kim, K.T.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.301-309
    • /
    • 2018
  • If galvanized steel is exposed to an outdoor environment, atmospheric corrosion will occur with time and red rust will form when the sacrificial protection capacity of zinc reaches its limit. With corrosion, the surface appearance of steel changes, and the properties of the exterior materials degrade. In this study, two kinds of galvanized steel, (GA and GI specimens) were subjected to an outdoor exposure test for 36 months in six regions of Korea. Chrominance (color, chroma, and brightness) and glossiness surface analyses were performed. The color change was not significant, regardless of the exposed area or the specimens tested. With increasing exposure times, the GA specimen became blackened by the formation of zinc oxide, and red coloration was increased by the formation of red rust. As the exposure time of GI specimen increased, the surface proceeded to blacken, but no red rust was formed and the color did not change significantly. Regardless of the outdoor exposure area or the specimen, longer exposure times led to lower glossiness, and this behavior appears to be influenced by the formation of zinc oxide.

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

The Study on the Acceleration Factor of Coastal Outdoor Corrosion test, Salt Spray Test and Accelerated Corrosion Test using 0.5wt% carbon steel (0.5wt% 탄소강을 이용한 해안 야외부식시험과 염수분무시험, 가속부식시험의 가속계수에 대한 연구)

  • Cho, E.Y.;Gwon, G.B.;Cho, D.H.;Kim, J.Y.
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.209-214
    • /
    • 2013
  • In the industry, accelerated corrosion test is used for the life time prediction. When anti-corrosion test proceeds in real environments, it is difficult that we predict and evaluate the corrosion life time because of the long test time such as 10 years or more time. Accelerated corrosion test and Salt spray test are able to test corrosion life time of products in the laboratory instead of outdoor corrosion test. Experimental procedure is selected for the corrosion standard specimen, exposure of the specimens, measurements of the mass loss and evaluating the mass loss data. As a result, the acceleration factor of the accelerated corrosion test to the outdoor corrosion test is 414.8. Therefore we can predict the corrosion life time of carbon steel during a short time period.

Understanding the Degradative Effects of Different Climatological Conditions on Architectural Coatings: Progress Report on Korea Institute of Construction Materials Site Comparison Study of Seosan (Korea) Outdoor Exposure Testing Facility

  • Choi, Yoon;Pyo, Soonjin;Seo, Junsik;Yang, Inmo;Kim, Seungjin;Kim, Sangmyoung
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.116-118
    • /
    • 2009
  • Korea Institute of Construction Materials founded Seosan Outdoor Exposure Test Site 2005 at Korea, which is a part of Worldwide Exposure Network (WEN). To evaluate the test site along with other exposure test sites, three different types of paints have been under real time weathering conditions at three major weathering test facilities around the world. Using these test specimens several spectroscopic experiments along with physical tests have been performed. Also acceleration tests have been performed using the same paints. The correlation of weathered paints among three different test facilities and accelerated test results has been compared. From the results the reliability of Seosan Weathering Test Facility and reasonable life time prediction tests are discussed.

Scenario Analysis of Personal Nitrogen Dioxide Exposure with Monte Carlo Simulation on Subway Station Workers in Seoul (확률론적 모의실험 기법을 이용한 일부 지하철 근무자들의 이산화질소 개인노출 시나리오 분석)

  • 손부순;장봉기;양원호
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 2001
  • The personal exposures of nitrogen dioxide(NO$_2$), microenvironmental levels and daily time activity patterns on Seoul subway station workers were measured from February 10 to March 12, 1999. Personal NO$_2$exposure for 24 hours were 29.40$\pm$9.75 ppb. NO$_2$level of occupational environment were 27.87$\pm$7.15 ppb in office, 33.60$\pm$8.64 ppb in platform and 50.13$\pm$13.04 ppb in outdoor. Personal exposure time of subway station workers was constituted as survey results with $7.94\pm$3.00 hours in office, $2.82\pm$1.63 hours in platform and 1 hours in outdoor. With above results, personal $NO_2$exposure distributions on subway station workers in Seoul were estimated with Monte Carlo simulation which uses statistical probabilistic theory on various exposure scenario testing. Some of distributions which did not have any formal patterns were assumed as custom distribution type. Estimated personal occupational $NO_2$exposure using time weighted average (TWA) model was 31.$29\pm$5.57 ppb, which were under Annual Ambient Standard (50ppb) of Korea. Though arithmetic means of measured personal $NO_2$exposure was lower than that of occupational $NO_2$exposure estimated by TWA model, considering probability distribution type simulated, probability distribution of measured personal $NO_2$exposures for 24 hours was over ambient standard with 3.23%, which was higher than those of occupational exposure(0.02%). Further research is needed for reducing these 24 hour $NO_2$personal excess exposures besides occupational exposure on subway station workers in Seoul.

  • PDF

Corrosion Behaviour of Some Alloys in Tropical Urban and Marine Atmospheres

  • Dang, Vu Ngoan;Bui, Ba Xuan;Nguyen, Nhi Tru
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.125-129
    • /
    • 2008
  • Results of corrosion testing for different grades of titanium, copper, zinc, alluminium alloys and steels after two years of outdoor exposure under humid tropical urban and marine conditions have been presented and discussed. Mass loss and corrosion product characteristics for the exposed specimens at Hanoi testing site with high humidity and Nhatrang marine stations (at 100 and 1,000 meters distances from sea) with different airborne salinities (35.9 and $90.0mg/m^2.d$ respectively) have been selected for investigation. From time dependence of the specimen mass loss and corrosion product characteristics, the strong influence of environmental parameters upon durability for the investigated metals and alloys has been demonstrated. Only titanium alloys show high resistance to the marine conditions. All the other specimens (copper, zinc, alluminium alloys and steels) have been underwent strong deterioration under influence of aerosol salinity. Results of corrosion products analysis have been also presented for characterization of environmental impact on the metal degradation processes.

Development of Aging Equipment and Testing Method for UV Effected Degradation Characteristics of Silicone Rubber (자외선 열화에 의한 실리콘고무의 열화 특성 연구를 위한 열화장치 및 시험방법의 개발)

  • Lee, Jeong-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.93-96
    • /
    • 2007
  • In this paper, the testing equipment for evaluating aging characteristics of outdoor silicone rubber insulator resulting from the environmental aging effect with regards to sunlight(UV) was developed. Influence of sunlight effect aging is seriously increase due to destruction of ozone layer which is occurred by consumption of fossil fuel. For this purpose, silicone rubber was aged under the artificial sunlight by exposure of xenon lamp radiation in the accelerating aging chamber and various test and analysis were performed such as breakdown strength, contact angle. And FT-IR analysis has been followed.

  • PDF

Accelerated SCC Testing of Stainless Steels According to Corrosion Resistance Classes

  • Borchert, M.;Mori, G.;Bischof, M.;Tomandl, A.
    • Corrosion Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.280-287
    • /
    • 2015
  • The German Guidelines for stainless steel in buildings (Z.30.3-6) issued by the German Institute for Building Technology (DIBt) categorizevarious stainless steel grades into five corrosion resistance classes (CRCs). Only 21 frequently used grades are approved and assigned to these CRCs. To assign new or less commonly used materials, a large program of outdoor exposure tests and laboratory tests is required. The present paper shows theresults of stress corrosion cracking (SCC) tests that can distinguish between different CRCs. Slow strain rate tests (SSRT) were performedin various media and at different temperatures. CRC IV could be distinguished from CRC II and CRC III with a 31.3 % $Cl^-$ as $MgCl_2$ solutionat $140^{\circ}C$. CRC II and CRC III could be differentiated by testing in a 30% $Cl^-$ as $MgCl_2$ solutionat $100^{\circ}C$.

A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall (커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구)

  • Jang, Pil Sung;Hong, Soon Gu;Kim, Sung Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.279-287
    • /
    • 2018
  • Sealants are an important element of modern architecture and serve as a building protection against weathering by providing barriers against ingress of moisture, air, and other materials. Exposure to a variety of environments often reduces lifespan due to changes in physical, chemical and mechanical characteristics, and UV, humidity, and temperature expansion are important issues that are directly related to durability. In this study, a combined deterioration test chamber was developed to simulate the environment of the open air as an instrument for verifying the durability of structural sealing materials indoors. In order to replicate special weather conditions, such as yellow dust, acid rain, and contamination by microorganisms, it was deemed impossible to replicate the outdoor environment by 100 %, and the results of the results of the results of the external exposure test of the structural sealant and the combined deterioration testing device. As a result of the displacement test of the outdoor exposure test, it was determined that the sealant was breaking apart and that it would be smooth, and the displacement would be up to three times greater than the initial material value of 1 year. The displacement test results of the combined deterioration test device show the tendency to deteriorate, decreasing the elasticity and tensile characteristics. In the case of denatured silicon, the current 400 cycles have been completed to confirm 12 months of degradation of the external exposure. The deformation of the test specimen cannot be verified with the naked eye, so it is considered that the conditions of the specimen are more stable than the silicon sealant. As a result of the outdoor exposure test, if the combined deterioration test device is structured and proposed in the relevant guidance or specification, the anticipated lifespan of 12 months in the actual use environment can be verified indoors and below 3 months later, economically.