• Title/Summary/Keyword: outdoor air quality

Search Result 207, Processing Time 0.022 seconds

Methyl-Tertiary Butyl Ether(MTBE) and BTEX Inside and Outside Apartments with Different Construction Age

  • Jo, Wan-Kuen;Lee, Jong-Hyo
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Only limited information is available on the measured exposure levels of residents according to the construction age of apartments. As such, present study was conducted to measure and to compare the bedroom, living-room, and outdoor air levels of MTBE and benzene, toluene, ethyl benzene and m,p-xylene(BTEX) in both newer and older apartments. For both newer and older apartments, all the compounds except for MTBE showed significantly higher levels in bedrooms or living-rooms as compared to the outdoor concentrations. The ratio of bedroom or living-room median concentration to outdoor concentration was close to 1 for MTBE, whereas it was larger than 1 for other target compounds. It was also found that the bedroom and living-room appeared to have similar indoor sources and sinks for BTEX, but not for MTBE. The median concentration ratios of the newer apartments to the older apartments ranged from 1.63 to 1.81, depending upon the compounds. In contrast, the MTBE concentrations did not differ significantly between the newer and older apartments, thereby suggesting that although newer buildings could emit more VOCs, this is not applicable to all VOCs. Conclusively, the findings of present study should be considered, when designing exposure studies associated with VOC emissions in buildings and/or managing indoor air quality according to construction age of buildings.

Iot based Indoor Air Quality Monitoring System (Iot 기반 실내 공기오염 측정 시스템)

  • Kim, Ungtae;Kim, Yong-Chul;Kwak, Sooyeong
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.143-151
    • /
    • 2016
  • Many people interested in indoor air quality monitoring since they spend a majority of their time indoors such as homes and offices. This paper proposes the effective indoor air quality monitoring system and it can gauge carbon dioxide, particulate matter and VOCs(Volatile Organic Compounds) which can be harmful to humans. The proposed system is composed of three main modules which are device, web server, and mobile application. In order to evaluate the performance, we tested two cases which are candle and smoke. We monitor the condition of indoor air quality with our mobile application. Also, we developed the information graphics to compare the condition of air quality between indoor and outdoor and this mobile application improves usability.

Exposure Assessments for Children in Homes and in Daycare Centers to NO2, PMs and Black Carbon

  • Lee, Jae Young;Kim, Changhyeok;Kim, Jongbum;Ryu, Sung Hee;Bae, Gwi-Nam
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.204-214
    • /
    • 2018
  • Indoor air quality was investigated in homes and daycares located in areas with heavy traffic in Seoul, South Korea from November 2013 to January 2014. Indoor and outdoor air quality measurements were collected for 48 hours in four children's homes and daycare centers. The I/O ratio (Indoor to outdoor ratio) for each major air pollutant ($NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$) was calculated, and $NO_2$ and $PM_{10}$ concentration profiles were analyzed based on indoor activity diaries recorded during the 48 hours. Most I/O ratios for $NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$ at daycare centers were less than one. At homes, I/O ratios for black carbon, $PM_{10}$, and $PM_{2.5}$ were less than one; however, most I/O ratios for $NO_2$ were greater than one due to the usage of gas stoves. The children's exposure to indoor air pollutants was calculated using a time-weighted average exposure method, and the daily intake level for each pollutant was determined.

Characteristics of concentration distribution for indoor air pollutants (VOCs and Carbonyl compounds) in new apartments (신축 공동주택에서 실내공기오염물질(휘발성유기화합물 및 카보닐화합물) 농도분포 특성)

  • Jang, Seong-Ki;Chun, Jae-Young;Lee, Tae-Young;Lim, Soo-Gil;Lu, Jung-Min;Seo, Soo-Yun;Lim, Jeong-Yun
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.17-24
    • /
    • 2007
  • This study was performed to investigate the distributions of volatile organic compounds and carbonyl compounds at the 120 households in new apartments before occupation. The concentration of toluene, m, p-xylene, formaldehyde, acetone and ethylbenzene dominated as $272.81{\mu}g/m^3$, $98.90{\mu}g/m^3$, $71.68{\mu}g/m^3$, $70.58{\mu}g/m^3$ and $49.76{\mu}g/m^3$, respectively. The identified compounds by standards occupied 42.5% of the TVOCs, also the concentration of toluene occupied the largest part of the identified compounds as 18.5%. The concentration of formaldehyde and acetone were 43.1% and 42.4% among carbonyl compounds. The indoor/outdoor ratio of the concentration of benzene, toluene, formaldehyde and o-xylene were investigated 1.29, 3.59, 10.76 and 28.74, respectively.

A Study on the Perception Level and Proper Management of Indoor Air Quality Recognition in Elderly Care Hospital Workers

  • Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.171-178
    • /
    • 2019
  • In this paper, we proposed a plan for a indoor air quality management in elderly care hospital by measuring the indoor air quality level of elderly care hospital and conducting a survey the workers' awareness of indoor air quality. The measurement items were Temperature, Humidity, CO2, CO, PM10, VOC and were taken on April 26, 2019. The survey found that the lower the satisfaction level with indoor air quality, the better outdoor air quality and odor items were analyzed to be the lowest among the indoor environmental factors. When the satisfaction level of indoor air quality is high, the satisfaction level of indoor environment factor is high. The result of the multiple response analysis was "lack of ventilation" and the regression analysis was the lower the "relevance of indoor air quality" category. To provide the best indoor air quality environment for elderly care hospital workers the installation of additional ventilation equipment to remove odors, the increase in the number of natural ventilation and the designation of regular ventilation personnel will be necessary. By establishing such a plan, it is possible to provide indoor air quality environment to provide the best services for elderly care hospital workers.

The Qualitative Study on Outdoor Sportswear Purchase Behavior -Focusing on Functional Fabric Awareness Level and Benefits Sought- (아웃도어 스포츠웨어 구매행동에 관한 질적 연구 -기능성 인지수준과 추구 혜택을 중심으로-)

  • Rhee, Young-Ju;Lee, Eun-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.5
    • /
    • pp.1088-1101
    • /
    • 2011
  • The purpose of this study was to examine the outdoor sportswear purchase behavior, outdoorwear sportswear brand preference, functional fabric awareness, and benefits sought. The research was performed through in-depth interview during February to March 2011. Data were collected from 10 consumers who had purchased outdoor sportswear and experienced camping in 6 months. First, the results from study showed that functionality/comfortability, design, color, and brand name were important factors in selecting outdoor sportswear. Offline stores were the main place to purchase, however, internet shopping mall and portal online community were another shopping channel as well. Second, respondents preferred imported outdoor sportswear brand to national brand. According to the study, the respondents trusted the imported outdoor sportswear quality based on the brand name, value, and brand history more than national brand. Third, consumers who had low functional fabric awareness were more likely to evaluate apparel products based on the brand name. Knowledge levels for textile functions were high in elastic, UV protection, air permeable, and antibacterial properties. The essential features for camping were water absorbing and quick dry, water resistance, wind proof, UV protection, and fire retardant properties. Finally the results showed that there were two sportswear benefit soughts: functionality and status ostentation.

Evaluation of Ventilation System Performance Using Indoor Air Quality Model (실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가)

  • 최성우
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings (외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포)

  • Park, Ju-Hyun;Yoon, sung-min;Song, Du-Sam;Kim, Yong-Sik
    • Journal of Urban Science
    • /
    • v.8 no.1
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.

Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent (고속버스의 환기구 형태에 따른 환기량 분석)

  • Shin, In-Hwaw;Yoo, Ho-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

Study on Indoor Thermal Comfort of Advanced EMU (차세대전동차의 실내온열환경 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Sung-Hyuk;Oh, Seh-Chan;Kim, Young-Nam
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1799-1802
    • /
    • 2008
  • More than 7 million people use the Seoul metropolitan subway network daily. This number tends to increase due to the increase of oil price. Indoor air quality of electrical multiple unit (EMU) is strongly affected by outdoor air quality, however, indoor thermal comfort is subjected to heating, ventilating, and air conditioning (HVAC) system of EMU. In general, air temperature, humidity, air velocity, surface temperature, and illumination are key parameters affecting thermal comfort of passenger. It is known that the well-designed HVAC system should improve the thermal comfort of passengers and should increase the energy efficiency of HVAC system also. In this study, we analyzed the thermal comfort of advanced EMU developed by Korea Railroad Research Institute by using the computational fluid dynamics (CFD) in order to find the optimum HVAC system which can improve thermal comfort of passengers with a minimal energy use.

  • PDF