Browse > Article
http://dx.doi.org/10.5392/JKCA.2016.16.02.143

Iot based Indoor Air Quality Monitoring System  

Kim, Ungtae (한밭대학교 전자.제어공학과)
Kim, Yong-Chul (한밭대학교 시각디자인학과)
Kwak, Sooyeong (한밭대학교 전자.제어공학과)
Publication Information
Abstract
Many people interested in indoor air quality monitoring since they spend a majority of their time indoors such as homes and offices. This paper proposes the effective indoor air quality monitoring system and it can gauge carbon dioxide, particulate matter and VOCs(Volatile Organic Compounds) which can be harmful to humans. The proposed system is composed of three main modules which are device, web server, and mobile application. In order to evaluate the performance, we tested two cases which are candle and smoke. We monitor the condition of indoor air quality with our mobile application. Also, we developed the information graphics to compare the condition of air quality between indoor and outdoor and this mobile application improves usability.
Keywords
Internet of Things; Particulate Matter; Indoor Air Quality;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Ministry of Environment, Environmental Epidemiology and the National Institute of Environmental Research Report, 2014.01.22.
2 Yunsin Kim, Indoor Environmental Science Topics, Xinguang Publisher, 2010.
3 Republic of Korea Ministry of Environment, A Study on Indoor Air Pollution Characterization and Management, Final Report, 2002.
4 K. W. Kim, H. D. Jun, and J. C. Park, "A study on the survey Indoor Environment in Child Care Center," Proceeding of 2009 Architectural Institute of Korea, Vol.29, No.1, pp.705-708, 2009(10).
5 S. P. Lee, "A Study on the Selectivity of Gas Sensors by Sensing Pattern Recognition," Journal of Sensor Science and Technology, Vol.20, No.6, pp.428-433, 2011(11).   DOI
6 S. J. Moon, "Technology and latest trends in the sensor industry," Monthly Automation System, Vol.5, pp.2-5, 2004.
7 U. S. Jung, M. H. Im, J. W. Kim, and C. U. Son, "Development of odor monitoring system of Siheung city using the smartphone application," Proceeding of 2012 Fall Conference on Korean Society of Odor Research and Engineering, pp.106-108, 2012(11).
8 S. Y Choi, J. S Choi, and S. C Kim, "Indoor Gas Monitoring System Using Smart Phone," Jouranl of Information and Security, Vol.12, No.1, pp.49-54, 2012(3).
9 J. H. Park, Y. I. Jun, and U. K. Lee, "IT convergence technology-based gas sensor technology for environmental monitoring," Information & Communications Magazine, Vol.25, No.6, pp.40-47, 2008(6).
10 Seung-Chul Lee and Wan-Young Chung, "Query-based Indoor air Quality monitoring system Using wireless sensor network inside the Building," The Institute of Electronics and Information Engineers, Vol.31, No.1, pp.627-628, 2008.
11 Seong-hyeon Ye and Soonhee Han, "Indoor Environment Monitoring System Using Short-range Wireless Communication in Mobile Devices," Journal of the Korea Institute of Information and Communication Engineering, Vol.17, No.9, pp.2167-2173, 2013.   DOI
12 Chang-Se Oh, Min-Seok Seo, Jung-Hyuck Lee, Sang-Hyun Kim, Young-Don Kim, and Hyun-Ju Park, "Indoor Air Quality Monitoring System in the IoT Environment," The Journal of Korean Institute of Communications and Information Sciences, Vol.40, No.5, pp.886-891, 2015.   DOI
13 http://spring.io