• Title/Summary/Keyword: organ transplantation

Search Result 225, Processing Time 0.023 seconds

Renal Biopsy (신장의 조직 검사)

  • Taek Min Kim;Jeong Yeon Cho;Sang Youn Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1198-1210
    • /
    • 2023
  • The extent of renal biopsy indication is being widened because of the increasing incidence of incidental renal masses; the increasing treatment options for renal cell carcinoma, including ablation therapy and novel targeted treatment; and the increasing incidence of kidney transplantation. However, percutaneous renal biopsy is technically difficult, particularly for beginners, because the skin-to-organ distance is relatively longer than those associated with other organs. In the present review, we will discuss the indications, technical considerations, efficacy, and complications of renal biopsy. Furthermore, we share practical tips of renal biopsy through many examples to help radiologists perform renal biopsy safely and effectively in various situations.

Histopathological Changes in Cold-Stored Dog Lungs to the Preservation Solutions (냉한에서 보관된 황견의 폐에서 장기 보존액에 따른 조직 세포의 변화)

  • 김해균;이두연
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.816-821
    • /
    • 1996
  • Lung transplantation is the established treatment for the end stage lung disedse find preservation of the organ is a major obstacle In performing lung transplantation. For solving this problem, we evaluated the histopathologic changes for various preservation solutions. Male mongrel dogs of similar size and weight (15∼20 kg) were used. The dog lungs were flushed with 4fl normal saline(group 1 'n:5): Modified Euro-Collins solution(group 2 n:5) and University of Wisconsin solution (group 3 : n=6), 60m11kg through a catheter placed in the main pulmonary artery aft r flushing of PGE 1 (20ng1kg). The lungs were preserved for 60 hours and measured dry and wet weights. Histologic specimens were taken every 6 hours and %toed for light microscopic evaluation. The edema ratio of the lungs peaked in 12 hours although there was no difference between the groups. Histologically, alveolar septal changes developed in one case (20%) after 1 hour preservation with normal saline. In case of the University of Wisconsin solution, the alveolar septal distortions and swellings were seen in 1 cases (20%) after 6 hours preservation compared with 3 cases (60%) after 6 hours preservation with Modified Euro-Collins solution. Changes of the pneumocytes were observed after 24 hours preser- vation in group 1, after 48 hours preservation in group 2 and after 60 hours preservation in group 3. We conclude that University of Wisconsin solution might have a superior preservation effect compare to normal saline and Modified Euro-Collins solutions.

  • PDF

Protective Effect of Nitroglycerin on the Ischemia-Reperfusion Model of the Isolated Rat Lung (흰쥐의 분리 폐장 관류 모델에서 Nitroglycerin의 폐장 보존 효과)

  • Jheon, Sang-Hoon;Lee, Sub;Lee, Jong-Hoon;Son, Bok-Kyoung;Cho, Gong-Rae;Chung, Jin-Yong;Cho, Soung-Kyung;Kim, Bong-Il;Lee, Young-Man;Choh, Joong-Haeng
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.894-903
    • /
    • 2003
  • Protection against ischemia-reperfusion injury is crucial for successful transplantation of the lung. It has been known that nitric oxide has many favorable effects on the donor lungs but at the same time, has some potential side effects of cytotoxicity. In this regards, we investigated whether the administration of nitroglycerin could decrease ischemia-reperfusion injury in isolated rat lung reperfusion model for the confirmation of the effect of nitroglycerin, a donor of nitric oxide, on lung transplantation. Material and Method: 35 Sprague-Dawley species male white rats were used for this experiment. For nitroglycerin group (n=18), nitroglycerin was administered intravenously followed by mixed in flushing solution for preservation. As a control group (n=17), we used the same amount of normal saline. To evaluate the effect of nitroglycerin on the lung, heart-lung block was obtained, weighed and stored in University of Wisconsin Solution at 1$0^{\circ}C$ for 24 hours. In each group of the isolated lungs, reperfusion was carried out with Krebs-Hensleit-diluted human blood for 60 minutes. As parameters of the state of the isolated lung, peak inspiratory and pulmonary arterial pressures were continuously recorded. Oxygen and carbon dioxide tension of reperfusing blood were measured before and after 30, 60 minutes of reperfusion. After sixty minutes of reperfusion, protein content in bronchoalveolar lavage fluid was measured also for the evaluation of the degree of alveolar flooding. Lung myeloperoxidase activity was determined to verify the accumulation of neutrophils. Results: Although statistically significant differences were not noted in peak inspiratory and pulmonary arterial pressure between control and nitroglycerin group, latter group showed lowering tendency of pulmonary arterial pressure during the entire reperfusion period. Oxygen tension was higher (p<0.05) in nitroglycerin group compared with that of the control group, in contrast, there were no differences in carbon dioxide tension, protein content in bronchoalveolar lavage fluid and myeloperoxidase activity between the groups. In the examination of ultrastructural changes, nitroglycerin denoted the protective effect on the pulmonary architecture compared with that of control group. Conclusion: Collectively, on the bases of these experimental results, prior treatment of donor lung with nitroglycerin could result in better preservation of the lung. Consequently, these nitroglycerin preserved lungs are thought to be more suitable for successful transplantation of the lung.

Inhibition of Graft Versus Host Disease Using CD4+CD25+ T Cells Induced with Interleukin-2 in Mismatched Allogeneic Murine Hematopoietic Stem Cell Transplantation (주조직적합항원이 불일치하는 마우스 동종 조혈모세포이식에서 IL-2로 유도된 CD4+CD25+ T세포를 이용한 이식편대숙주병의 억제)

  • Hyun, Jae Ho;Jeong, Dae Chul;Chung, Nak Gyun;Park, Soo Jeong;Min, Woo Sung;Kim, Tai Gyu;Choi, Byung Ock;Kim, Won Il;Han, Chi Wha;Kim, Hack Ki
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.287-294
    • /
    • 2003
  • Background: In kidney transplantation, donor specific transfusion may induce tolerance as a result of some immune regulatory cells against the graft. In organ transplantation, the immune state arises from a relationship between the immunocompromised graft and the immunocompetent host. However, a reverse immunological situation exists between the graft and the host in hematopoietic stem cell transplantation (HSCT). In addition, early IL-2 injections after an allogeneic murine HSCT have been shown to prevent lethal graft versus host disease (GVHD) due to CD4+ cells. We investigated the induction of the regulatory CD4+CD25+ cells after a transfusion of irradiated recipient cells with IL-2 into a donor. Methods: The splenocytes (SP) were obtained from 6 week-old BALB/c mice ($H-2^d$) and irradiated as a single cell suspension. The donor mice (C3H/He, $H-2^k$) received $5{\times}10^6$ irradiated SP, and 5,000 IU IL-2 injected intraperitoneally on the day prior to HSCT. The CD4+CD25+ cell populations in SP treated C3H/He were analyzed. In order to determine the in vivo effect of CD4+CD25+ cells, the lethally irradiated BALB/c were transplanted with $1{\times}10^7$ donor BM and $5{\times}10^6$ CD4+CD25+ cells. The other recipient mice received either $1{\times}10^7$ donor BM with $5{\times}10^6$ CD4+ CD25- cells or the untreated SP. The survival and GVHD was assessed daily by a clinical scoring system. Results: In the MLR assay, BALB/c SP was used as a stimulator with C3H/He SP, as a responder, with or without treatment. The inhibition of proliferation was $30.0{\pm}13%$ compared to the control. In addition, the MLR with either the CD4+CD25+ or CD4+CD25- cells, which were isolated by MidiMacs, from the C3H/He SP treated with the recipient SP and IL-2 was evaluated. The donor SP treated with the recipient cells and IL-2 contained more CD4+CD25+ cells ($5.4{\pm}1.5%$) than the untreated mice SP ($1.4{\pm}0.3%$)(P<0.01). There was a profound inhibition in the CD4+CD25+ cells ($61.1{\pm}6.1%$), but a marked proliferation in the CD4+CD25- cells ($129.8{\pm}65.2%$). Mice in the CD4+CD25+ group showed low GVHD scores and a slow progression from the post-HSCT day 4 to day 9, but those in the control and CD4+CD25- groups had a high score and rapid progression (P<0.001). The probability of survival was 83.3% in the CD4+CD25+ group until post-HSC day 35 and all mice in the control and CD4+CD25- groups died on post-HSCT day 8 or 9 (P=0.0105). Conclusion: Donor graft engineering with irradiated recipient SP and IL-2 (recipient specific transfusion) can induce abundant regulatory CD4+CD25+ cells to prevent GVHD.

Clinical Characteristics of Tuberculosis in Liver or Heart Transplant Recipients (간 또는 심장이식을 시행 받은 환자에서의 결핵의 발생률 및 임상양상)

  • Jung, Hoon;Oh, Yeon-Mok;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Kim, Jae-Joong;Lee, Sung-Gyu;Shim, Tae-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.5
    • /
    • pp.440-446
    • /
    • 2006
  • Background: Post-transplant tuberculosis (TB) is a serious complication in solid organ transplant recipients worldwide, However there is little or no data on TB in liver or heart transplant recipients in Korea. Methods: The incidence and clinical characteristics of TB of 730 patients who had undergone a liver transplant in a university hospital in Korea between 1992 and 2004, and 110 heart transplant recipients in the same period, were reviewed retrospectively. Results: The incidence of TB was 1.5%(11/730) and 2.7%(3/110) in the liver and heart transplantation, respectively. The median time from the transplant to the development of TB was 8.4 months(1.0-30.8). and the mean time from the symptoms to the diagnosis of TB was $2.1{\pm}3.6$ months(0.3-13.2). Nine patients (65%) had pulmonary TB and five (35%) had extrapulmonary TB. The leukopenia and positive HbeAg at the baseline, post-transplant diabetes mellitus, and chronic rejection were associated with the development of TB in the liver transplant recipients. Ten patients were treated with a 4-drug standard regimen for a mean duration of $7.8{\pm}3.5$ months. One patients died of TB. Conclusion: The incidence of TB in liver or heart transplant recipients was similar to that reported in other countries with a similar TB-burden.

T-SPOT.TB for Detection of Tuberculosis Infection among Hematological Malignancy Patients and Hematopoietic Stem Cell Transplant Recipients

  • Qin, Li-Li;Wang, Qin-Rong;Wang, Qian;Yao, Hong;Wen, Li-Jun;Wu, Li-Li;Ping, Na-Na;Xie, Jun-Dan;Chen, Mei-Yu;Chen, Su-Ning
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7415-7419
    • /
    • 2013
  • The diagnosis of latent Mycobacterium tuberculosis infection (LTBI) is recommended in hematological malignancy patients and before hematopoietic stem cell transplantation (Guidelines for the prevention and management of infectious complications of solid organ transplantation, 2004). Compared to traditional methods such as tuberculin skin test (TST), T-SPOT.TB has been shown to be more specific. In the present study we enrolled 536 patients for whom T-SPOT.TB was performed, among which 295 patients also received the TST test. The agreement (79%) between T-SPOT.TB and TST was poor (x=0.274, P<0.001). The patients with positive T-SPOT.TB results numbered 62 (11.6%), in which only 20 (48.8%) of the 41 receiving the TST test had positive results. A majority of the patients with T-SPOT.TB positive results had some other evidence ofTB, such as TB history, clinical symptoms and an abnormal chest CT scan. Active TB was found in 9 patients, in which 2 had negative TST results. We followed up the patients and no one developed active TB. Our study suggested that the T-SPOT.TB may be more useful for screening LTBI and active TB in hematological malignancy patients and hematopoietic stem cell transplant recipients than the TST test.

Complement-dependent Cytotoxic Crossmatch for Prevention of Hyperacute Rejection in Canine Renal Allografts (개의 신장 동종 이식에서 초급성 거부반응의 예방을 위한 보체의존성 세포독성 DLA 플래스 I 교차 반응)

  • Ghil Heh Myung;Woo Heung-Myung
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.322-327
    • /
    • 2005
  • DLA class I complement-dependent cytotoxicity (CDC) cross-match method was established to control hyperacute rejections in organ transplantation. The aim of the present study is to investigate if DLA class 1 CDC corssmatch method is effective to prevent hyperacute rejections in canine renal allografts. Seven mongrel dogs of similar age and weight were used. Erythrocyte crossmatch was first performed and only the negatives were used. Among the same blood types, CDC cross-match was performed. Anti-dog serum, Hank's balanced salt solution(HBSS), and tile self-serum was used as a positive-, a negative-, and all auto-control respectively. After the reaction with class I complement, it was stained with eosin and scored by international cytotoxicity scoring system under inverted phase microscope. According to these results, kidneys oi CDC negatives among same blood types were cross-transplanted to observe the incidence of hyperacute rejections. One of four 1.2 B blood type dogs had autoantibodies. here were negative CDC results among each blood type, and also there were negative results between different blood types. Two pairs with the same blood types and negative CDC results underwent allo-transplantation each other. There were no hyperacute rejections. DLA cross-match method studied in this experiment for canine renal allograft can be effective to prevent hyperacute rejections. it may be applicable for the future studies of histocompatibility testing in canine renal allografts.

Comparative Study of Prolonged Preservation Methods in Rabbit Heart for Transplantation (이식을 위한 가토심장의 장기 보존방법에 관한 비교 연구)

  • Jo, Hyeong-Gon;Kim, Su-Hyeon;Kim, Song-Myeong
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • The successful cardiac transplantation depends partly on the donor heart preservation by a solution that will ensure recovery of myocardial function. The purpose of this study was to perform the evaluation of various preservation solutions and to accumulate the data on the requisites for ideal preservation solution. The experimental setup was the constant pressure Langendorffs perfusion system. Isolated rabbit hearts were perfused for 20minutes with unarm Krebs-Henseleit solution, stored for 4 hours in cold preservation solution after cardioplegia, and then were reperfused for 20minutes. The 4 experimental groups were prepared Hartmann's solution group (group 1, control), modified Euro-collins solution group(group II. MEC), modified University of Wisconsin group (group n, MUW), and CK solution(made by the author) group (group W, CK). The parameters for assessing the preservation ability were levels of enzymes in freezed myocardial tissues (lactate, creatine kinase-MB and adenosine deaminase), coronary flow. left ventricular developing pressure and dpldt. In conclusion, the ability of preservation for isolated rabbit heart was excellent in CK solution and modified University of Wisconsin solution, and poor in modified Euro-collins solution, compared with Hartmann solution. CK solution has low potassium concentrations(34.2mEq/L) and includes various substrates to be salutary on myocardial preservation. This fact may indicates the necessity of further refinements in selection or composition of electrolytes and substrates.

  • PDF

Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit (벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템)

  • Kim, Bum-Soo;Lee, Jung-Joo;Nam, Kyung-Won;Jeong, Gi-Seok;Ahn, Chi-Bum;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.

Pulsatility Estimation of a Pulsatile Decellularizing Device for the Fabrication of Organ Scaffold (생체장기용 지지체 제작을 위한 박동형 탈세포화 장치의 박동성 평가)

  • Kim, Dong Sun;Yang, Se-Ran;Park, Sung Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.62-73
    • /
    • 2017
  • To identify a solution for the restricted availability of healthy lungs and the high risk of immune rejections following organ transplantation, tissue engineering techniques for culturing lungs have been studied by many research groups. The most promising method for culturing lungs is the utilization of a bio-scaffold that was prepared using harvested organs from human donors or other animals by removing their original cells. In this study, a pulsatile perfusion pump was used to alleviate the cell removal effect with the high fluid-dynamic power of the perfusion stream during the decellularization process, while other conventional studies focused on chemical methods to identify efficient detergents. The purpose of this study was to analyze the developed device by using energy equivalent pressure (EEP), which is an indicator of pulsatility, to understand the characteristics of pulsatile energy transmitted according to the load size by using the artificial model and compare it with the measured EEP. The pulsatility of the device can be estimated with the concept of fluid-dynamic energy during a particular constant time period or fluid-dynamic power represented as EEP and EEP increment. Because the measured EEP of perfusion flow during decellularization can be changed by the amount of fluid leakage and the degree of clogging in the capillary vessels, EEP should be measured to determine whether the decellularization is progressing without problems. The decrement of EEP caused by the high perfusion resistance was observed from some experimental results that were obtained with artificial models. EEP can be used to monitor the decellularization process after analyzing the varying EEP according to the amount of load. It was confirmed that the EEP was maintained at a high level in the experiment using the harvested lungs from 12-13-week-old rats. In addition, it was confirmed that the cell removal time was faster than when continuous perfusion was performed. In this study, pulsatile power delivered to the lungs was measured to monitor the process of cell removal, and it serve as the evidence for efficient decellularization.