• Title/Summary/Keyword: oral reading

Search Result 78, Processing Time 0.028 seconds

Semiotic Approaches to New Archival Methodology (새로운 기록방법론을 위한 기호론적 접근)

  • Lee, Youngnam;Jo, Minji
    • The Korean Journal of Archival Studies
    • /
    • no.41
    • /
    • pp.113-173
    • /
    • 2014
  • For the past few years, there has been active seeking of archival practices outside of public institutions. For example, there is oral history archive which has an actual field of its own, community archive, archives of everyday life, cultural resources archive, digital archive, and post-modern archive with its discourse practical character. In this reading, such flow is organized through everyday paradigm, and examines new archival methodology that is suitable for it. Through such critical mind, semiotic approach is taken and the need, direction and alternative of archival methodology is offered. Especially, archival methodology, which can be applied to archives is thoroughly observed. Also, the way how sign practices can be executed in the archival field is explained through specific examples. Of course, it is clearly stated that this is an instance, and that it is an archival methodology that can be applied to public institutions. We hope this would be a discuss that would enable a comprehensive understanding of records.

Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis

  • Chagas, Mariana Murai;Kobayashi-Velasco, Solange;Gimenez, Thais;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.363-372
    • /
    • 2021
  • Purpose: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. Materials and Methods: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. Results: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects(0.73) and fenestration defects(0.87) showed a statistically significant difference. Conclusion: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.

Usefulness of Gastric Emptying Time Test for Dog byUsing Radiopaque Marker KOLOMARK (비투과 표지자 KOLOMARK를 이용한 개의 위배출시간검사에 대한 유용성)

  • Cho, Young-Kwon;Kim, Seon-Chil
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.267-273
    • /
    • 2012
  • Abnormal gastric emptying time of dog by alien substance, neoplasm, pyloric antrum hyperplasia, stomach surgery, electrolyte imbalance, stomach-dilated torsion is clinically important as a digestive disease. Therefore study aims to provide basic data on the clinical usefulness of gastric emptying time test which uses radiopaque Kolomark developed in Korea rather than using the existing BIPS for the dog. 9 beagles were used for this experiment and their average weight was about 10.3kg with 2.5 year-old average age. For the test, fast for 12 hours was made without chemical sedation, and just before the test, 1 capsule of Kolomark was fed with 25% of daily feed amount, and we took photographs at ventrodorsal and right lateral position after 2, 4, 8 and 12 hours. As for interested reading area, we observed entire stomach from cardia to stomach pyloric part, and as for analysis method, we counted Kolomarks remained in the stomach per time and judged only P value below 0.05 to be meaningful by using Friedman Test. After feeding Kolomark through oral cavity, it took average 7.55 hours for the Kolomark to have escaped from the stomach to small intestine. In this study of gastrointestinal tract passing time after feeding matured dog, we used Kolomark and expect that it could be a basic data for normal gastrokinetic time.

Inhibitory Effects of a Recombinant Viral Cystatin Protein on Insect Immune and Development (바이러스 유래 시스타틴 재조합 단백질의 곤충 면역 및 발육 억제효과)

  • Kim, Yeongtae;Eom, Seonghyun;Park, Jiyeong;Kim, Yonggyun
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.331-338
    • /
    • 2014
  • Cystatins (CSTs) are reversible and competitive inhibitors of C1A cysteine proteases, corresponding to papain-like cathepsins in plants and animals. A viral CST (CpBV-CST1) was identified from a polydnavirus, Cotesia plutellae bracovirus (CpBV). Our previous study indicated that a transient expression of CpBV-CST1 interfered with immune response and development of Plutella xylostella larvae. To directly demonstrate the protein function, this study produced a recombinant CpBV-CST1 protein (rCpBV-CST1) using bacterial expression system to determine its inhibitory activity against cysteine protease and to assess its physiological alteration in insect immune and development. The open reading frame of CpBV-CST1 encodes a polypeptide of 138 amino acids (${\approx}15kDa$). rCpBV-cystatin protein in BL21 STAR (DE3) competent cells containing a recombinant pGEX4T-3:CpBV-CST1 was over-expressed by 0.5 mM IPTG for 4 h. In biological activity assay, the purified rCpBV-CST1 showed a significant inhibition against papain activity. It inhibited a cellular immune response of hemocyte nodule formation in the beet armyworm, Spodoptera exigua. Moreover, its oral administration retarded larval development of the diamondback moth, Plutella xylostella in a dose-dependent manner. These results suggest that CpBV-CST1 may be applied to control insect pest populations.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Evaluation of Usefulness on In-vivo Diode Dosimetry for Measuring the Tumor Dose of Oral Cancer Patient (구강암 환자의 종양 선량 측정을 위한 In-vivo Diode Dosimetry의 유용성 평가)

  • Na Kyung-Su;Lee Je-Hee;Park Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2005
  • Purpose : This test is designed to identify the validity of treatment plan by implementing real-time dosimetry by means of dose that is absorbed into PTV and OAR when preparing doses of 3D and POP plans. Materials and Methods : In treatment. error can be calculated be comparing Exp. Dose with the actual dose, which has been converted from 'the reading value obtained by placing diode detector on the area to be measured'. Same test can be repeated using Alderson-Rando phantom. Results : Errors were found: A patient(POP plan): 197.6/199=-1.2%, B patient(3D-plan): 199.9/198.7=+0.6%, C patient: 196/200=-1.5%. In addition, considering the resulted value of measuring OAR besides target-dose for C patient showed 96/200, representing does of 47%, the purpose of protection was judged to be duly accomplished. Also it was acknowledged the resulted value of -3.7% met the targeted dose within the range of ${\pm}5%$. Conclusion : Aimed for identifying the usefulness of pre-treatment dose measurement using diode detector, this test was useful to evaluate the validity of curing because it resulted in the identification of category to be protected as well as t dose. Moreover, it is thought to have great advantage in ascertaining the dose of target, dose of which is not calculated yet. Similar to L-gram before treatment, this test is thought to be very effective so that it can bring great advantages in the aspects such as validity of curing method and post-treatment plan as well.

  • PDF

The Characteristics of the Exhibits in Science Centers and Students' Perceptions About the Exhibits -In the Case of 3 Science Centers in Seoul- (과학관 전시물의 특징과 학생들의 전시물에 대한 인식 -서울시 소재 3개 과학관을 중심으로-)

  • Kim, So-Hee;Song, Jin-Woong
    • Journal of The Korean Association For Science Education
    • /
    • v.23 no.5
    • /
    • pp.544-560
    • /
    • 2003
  • The purposes of this study were (1) to investigate the characteristics of the exhibits at three representative science centers or museums in Seoul, and (2) to analyse students' perceptions about the most and the least favorite exhibits selected by students as visitors. Three science centers investigated were Seoul National Science Museum, Seoul Education & Science Research Institute, LG Science Hall. The subjects for students' perception survey were 290 middle school students who visited the three science centers. The investigation of the exhibits showed that the goals, the contents, the visitors' viewing and manipulating activity types, and the explanation types of the exhibits depended on the purposes and the target visitors of each science center. Students' responses indicated that they most favored hands-on exhibit. And students preferred the exhibits that had new and comprehensible contents and the were related to what they had learned in school. Students said that they felt that science was exciting and that they came to experience what they did not do in school. Students said that reading or hearing given explanations was helpful to understand the exhibits, but about 20% of the students responded that they did not read explanation on panels at all. Students also said that guide's oral explanations were more understandable than written explanations on panels. Some of the students commented that having to wait for access because of crowds or because of the resetting time required for hands-on activities was inconvenience.