• 제목/요약/키워드: optoelectronic system

검색결과 92건 처리시간 0.029초

High Shock-Resistant Design of Piezoresistive High-g Accelerometer

  • Yongle Lu;Zhen Qu;Jie Yang;Wenxin Wang;Wenbo Wang;Yu Liu
    • Journal of Information Processing Systems
    • /
    • 제19권2호
    • /
    • pp.173-188
    • /
    • 2023
  • To improve the shock-resistance of piezoresistive high-g accelerometer, we propose a design of piezoresistive high-g accelerometer. The accelerometer employs special-shaped proof masses system with a cross gap. Four tiny sensing beams are bonded above the cross gap. The expression of the deformation, natural frequency and damping is deduced, and the structural parameters are optimized. The accelerometer structure is simulated and verified by finite element method (FEM) simulation. The results show that the range of the accelerometer can reach 200,000 g, the natural frequency is 453.6 kHz, and the cross-axis sensitivity of X-axis and Y-axis is 0.25% and 0.11%, respectively, which can apply to the measurement of high shock. Contrastively, the cross-axis sensitivity of X-axis and Y-axis is respectively, reduced by 93.2% and 96.9%. The sensitivity of our accelerometer is 0.88 μV/g. It is of great value for the application of piezoresistive high-g accelerometer with high shock-resistance.

Conceptual design and analysis of remote steering system for CFETR ECRH system

  • Chao Zhang;Xiaojie Wang;Dajun Wu;Yunying Tang;Hanlin Wang;Dingzhen Li;Fukun Liu;Muquan Wu;Peiguang Yan;Xiang Gao;Jiangang Li
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.451-462
    • /
    • 2024
  • In order to optimize the operational safety and reliability of the upper launcher for the CFETR ECRH system, a design of the launcher based on the remote steering concept is currently being carried out for comparison with the front steering equivalent. This paper presents the remote steering system's conceptual design and simulation analysis. A Square Corrugated Waveguide (SCW) of 65 × 65 mm has been designed with an optimized length of 9.35 m. By changing the relative length of the waveguide, the transmission efficiency of the SCW is optimized within the range of steering angles ±12°. Different error factors are investigated in detail, and corresponding acceptable error ranges are provided. Considering these error factors and ignoring ohmic losses and thermal effects, the relative transmission efficiency of the SCW is estimated to be >98 % within the steering angle range. A matching steering unit for the SCW is designed, which consists of an ellipsoidal focusing mirror and a steerable flat mirror. The detailed design of the steerable mirror motion trajectory is presented. Also, the influence of the possible beam incident errors caused by the steering unit on the transmission efficiency is analyzed in detail.

Design and evaluation of an innovative LWR fuel combined dual-cooled annular geometry and SiC cladding materials

  • Deng, Yangbin;Liu, Minghao;Qiu, Bowen;Yin, Yuan;Gong, Xing;Huang, Xi;Pang, Bo;Li, Yongchun
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.178-187
    • /
    • 2021
  • Dual-cooled annular fuel allows a significant increase in power density while maintaining or improving safety margins. However, the dual-cooled design brings much higher Zircaloy charge in reactor core, which could cause a great threaten of hydrogen explosion during severe accidents. Hence, an innovative fuel combined dual-cooled annular geometry and SiC cladding was proposed for the first time in this study. Capabilities of fuel design and behavior simulation were developed for this new fuel by the upgrade of FROBA-ANNULAR code. Considering characteristics of both SiC cladding and dual-cooled annular geometry, the basic fuel design was proposed and preliminary proved to be feasible. After that, a design optimization study was conducted, and the optimal values of as-fabricated plenum pressure and gas gap sizes were obtained. Finally, the performance simulation of the new fuel was carried out with the full consideration of realistic operation conditions. Results indicate that in addition to possessing advantages of both dual-cooled annular fuel and accident tolerant cladding at the same time, this innovative fuel could overcome the brittle failure issue of SiC induced by pellet-cladding interaction.

무선 광통신에서 광전 궤환을 이용한 잡음 광의 영향 감소 (Reducing the Effects of Noise Light in an Wireless Optical Communication Using Optoelectronic Feedback)

  • 황다현;이성호
    • 한국전자파학회논문지
    • /
    • 제21권10호
    • /
    • pp.1136-1142
    • /
    • 2010
  • 본 논문에서는 조명용 LED를 광원으로 사용한 무선 광통신 시스템에서 광전 궤환을 이용한 ASK 변조 방식을 사용하여 잡음 광의 간섭을 소거하였다. 광전 궤환 회로의 발진을 이용하여 70 kHz의 반송파를 자체적으로 생성하였으며, 입력 신호를 사용하여 궤환 회로의 단락과 개방을 반복함으로써 9.6 kbps의 데이터 속도로 출력광을 ASK 변조하였다. 주변의 잡음 광이 존재하는 환경에서 광전 궤환을 이용한 ASK 변조 방식을 사용함으로써 신호대 잡음비가 약 25 dB 개선되었다.

A Miniaturized Catadioptric Laser-Irradiation-Precision Test System

  • Liu, Huan;Sun, Hao;Wang, Chunyan
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.164-172
    • /
    • 2021
  • In this paper a catadioptric laser-irradiation-precision test system is designed, to achieve a high-precision laser-irradiation-accuracy test. In this system, we adopt the method of imaging the entire target surface at a certain distance to realize the measurement of laser-irradiation precision. The method possesses the advantages of convenient operation, high sensitivity, and good stability. To meet the test accuracy requirement of 100 mm/km (0.01%), the coma, field curvature, and distortion over the entire field of view should be eliminated from the optical system's design. Taking into account the whole length of the tube and the influence of stray light on the structure type, a catadioptric system with a hood added near the primary imaging surface is designed. After optimization using the ZEMAX software, the modulation transfer function (MTF) of the designed optical system is 0.6 at 30 lp/mm, the full-field-of-view distortion is better than 0.18%, and the energy concentration in the 10-㎛-radius surrounding circle reaches about 90%. The illumination-accuracy test results show that the measurement accuracy of the radiation hit rate is better than 50 mm when the test distance is 1 km, which is better than the requirement of 100 mm/km for the laser-irradiation-accuracy test.

광학추적항법장치를 이용한 르포씨 제1형 골절단 가상 수술의 정확성에 대한 연구 (Accuracy of simulation surgery of Le Fort I osteotomy using optoelectronic tracking navigation system)

  • 부연지;김성민;김지연;박정민;명훈;이종호;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권2호
    • /
    • pp.114-121
    • /
    • 2011
  • Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint, using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3 points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1) Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system I s relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

Recent progress in oxide phosphor thin-film electroluminescent devices

  • Minami, Tadatsugu;Miyata, Toshihiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.27-32
    • /
    • 2006
  • The present status and prospects for further development of thin-film electroluminescent (TFEL) devices using oxide phosphors are described. High-luminance oxide TFEL devices have been recently developed using a new combinatorial deposition technique featuring rf magnetron sputtering with a subdivided powder target. In addition, new flexible oxide TFEL devices have been fabricated on an oxide ceramic sheet and operated stably in air above $200^{\circ}C$.

  • PDF

합성 열안정제에 의한 나일론 4의 분해거동 (Degradation Behavior of Nylon 4 in the Presence of Newly Synthesized Thermal Stabilizers)

  • 장근석;김종호;김대근;김영준;이택승
    • 폴리머
    • /
    • 제38권3호
    • /
    • pp.314-319
    • /
    • 2014
  • 힌더드 아민기를 포함하고 있는 헤테로환을 가지며 알킬사슬 길이가 서로 다른 세 종류의 나일론 4 열안정제를 합성하였다. 힌더드 아민기를 이용하여 라디칼에 의한 열분해를 방지하고, 열안정제와 나일론 4의 아마이드기 간 수소결합을 조절하여 나일론 4의 열적 특성에 미치는 영향을 확인하였다. 안정제의 알킬사슬의 수가 4개일 때 수소결합이 가장 최적화되는 것으로 등온 TGA 결과를 통해서 확인하였다. 또한 시판중인 나일론 6의 열안정제를 사용하여 나일론 4에 대한 열안정성을 비교 실험한 결과, 합성 열안정제가 나일론 4의 열안정성을 실질적으로 향상시킨 것을 확인하였다.