• Title/Summary/Keyword: optimum measurement

Search Result 703, Processing Time 0.03 seconds

Acquisition Model for 3D Shape Measurement Data

  • Park, Jong-Sik;Jang, Wang-Jin;Lee, Seong-Beom;Park, Chan-Seok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.16-21
    • /
    • 2008
  • The demand for three-dimensional (3D) shape measurements is increasing in a variety of fields, including the manufacture of molds and dies. The most popular technology for 3D shape measurement is the coordinate measuring machine (CMM) with a contact trigger probe. Although a CMM provides a high degree of accuracy, it is inefficient due to its long measuring time. It also has difficulty measuring soft objects that can be deformed by the touch of the contact probe. In addition, a CMM cannot digitize areas that are difficult to reach, and cannot capture very minute details on the surface of complex parts. For these reasons, optical non-contact measurement techniques are receiving more attention since they eliminate most of the problems associated with contact methods. Laser scanning is emerging as one of the more promising non-contact measurement techniques. This paper describes various acquisition considerations for laser scanning, including the accuracy of the 3D scan data, which depends on the charge-coupled device (CCD) gain and noise. The CCD gain and noise of a 3D laser scanner are varied while keeping the other conditions constant, and the measurement results are compared to the dimensions of a standard model. The experimental results show that a considerable time savings and an optimum degree of accuracy are possible by selecting the proper CCD gain and noise.

Study on the Basic Bodice Pattern Grading according to the Measurement Variations of the Body (인체 부위별 치수증감을 반영한 길 원형 그레이딩에 관한 연구)

  • Jung, Myoung-Sook
    • The Korean Journal of Community Living Science
    • /
    • v.20 no.4
    • /
    • pp.571-578
    • /
    • 2009
  • This study was to apply the measurement variations of each region of the body to the basic bodice pattern grading and to provide the clothing pattern fit for the human body. Grading variation used in the apparel industry was researched and new grading variation was proposed by analyzing the statistical data of body measurements. The statistical variation in body measurements was applied to set the optimum grading region and variation. Five sizes were used by split grading method and drawn with Bust Circumference and waist length based on the middle size. Differences between the grading pattern and the drawing pattern were analyzed by overlapping them and measuring each region. The measurement variations of drawing patterns between the sizes were very different from those of statistical data. On the other hand, the measurement variations of grading patterns between the sizes and those of statistical data were similar. In summary, the grading pattern by applying the measurement variations to the region of the body was superior to the drawing pattern drawn by the basic measurements for clothing fitness.

  • PDF

Measurement of critical time for optimum backpulsing time (최적 역충격을 위한 임계시간 측정)

  • 박상현;장진호;노수홍
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.169-171
    • /
    • 1998
  • 막오염을 저감하는 여러 방법중의 하나인 backpulsing은 짧은 시간동안 고빈도로 역세척을 하는 것이다. 본 연구는 주기적인 역충격(frequence backpulsing)에 의한 중공사막의 오염을 줄이는데 있어서 적절한 역세 주기를 구하기 위하여 막이 오염되기 이전의 순수투과능을 나타내는 시간인 임계시간(critical time)을 구하는 것이 목적이다.

  • PDF

Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement

  • Kim, Eunjong;Lee, Dong-Hyun;Won, Seunggun;Ahn, Heekwon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.5
    • /
    • pp.753-758
    • /
    • 2016
  • Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull) and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull) were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg $O_2/g$ VS d) were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS's optimum moisture content was near saturated state, its free air space kept a favorable level (above 30%) for aerobic composting due to the sawdust's coarse particle size and bulking effect.

Simple Determination Method on Optimal Dosage of Polymer for Papermaking Wastewater Treatment (제지폐수처리의 고분자 응집제 주입량 간이 결정법)

  • Cho, Jun-Hyung;Kang, Mee-Ran;Jin, Hai-Lan
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.1
    • /
    • pp.85-90
    • /
    • 2014
  • Dewaterability, one of the important properties of wastewater sludge, was investigated using a simple capillary suction time (CST) measurement method. CST and SRF have a very close co-relation. It was convinced that CST method was quite effective, and compensating the time-consuming SRF of conventional drainage measuring method. It turned out that one could use the results of CST to find optimum flocculants ratio to improve drainage in wastewater treatment for the tissue paper production at a mill. Since the optimum ratio of flocculants could be determined with the value of CST and COD removal efficiency could be improved with precise ratio of flocculants. Thus, using CST for determining the optimum ratio of flocculants could be economical by reducing the amount of flocculants. Dewaterability might be measured within several seconds using the values of CST in a precise way. The dewaterability could also be useful in investigating the optimum ratio of flocculants.

Maximum Power Tracking Control for parallel-operated DFIG Based on Fuzzy-PID Controller

  • Gao, Yang;Ai, Qian
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2268-2277
    • /
    • 2017
  • As constantly increasing wind power penetrates power grid, wind power plants (WPPs) are exerting a direct influence on the traditional power system. Most of WPPs are using variable speed constant frequency (VSCF) wind turbines equipped with doubly fed induction generators (DFIGs) due to their high efficiency over other wind turbine generators (WTGs). Therefore, the analysis of DFIG has attracted considerable attention. Precisely measuring optimum reference speed is basis of utilized maximum wind power in electric power generation. If the measurement of wind speed can be easily taken, the reference of rotation speed can be easily calculated by known system's parameters. However, considering the varying wind speed at different locations of blade, the turbulence and tower shadow also increase the difficulty of its measurement. The aim of this study is to design fuzzy controllers to replace the wind speedometer to track the optimum generator speed based on the errors of generator output power and rotation speed in varying wind speed. Besides, this paper proposes the fuzzy adaptive PID control to replace traditional PID control under rated wind speed in variable-pitch wind turbine, which can detect and analyze important aspects, such as unforeseeable conditions, parameters delay and interference in the control process, and conducts online optimal adjustment of PID parameters to fulfill the requirement of variable pitch control system.

Upgrading the Measurement Method of Biodegradable Dissolved Organic Carbon in Natural Water or Drinking Water (자연수 및 먹는 물 중의 생물학적 분해가능한 용존유기탄소의 측정방법 개선에 관한 연구)

  • 이윤진;윤재섭;박준석;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.3
    • /
    • pp.34-41
    • /
    • 2001
  • It is well known that bioassay on the low organic matters in water have developed from the two methods. One is assimilable organic carbon(AOC) that makes use of the maximum growth biomass of the pure strains for the standard substrates, the other is biodegradable dissolved organic carbon(BDOC) that determines the fraction of dissolved organic carbon(DOC) available for microbial utilization. The purpose of this study was to upgrade the measurement method of BDOC in natural water or drinking water. BBOC was determined by means of the bacterial growth and the DOC decrease at the same time. The origin inoculums were used to the suspended bacteria from Han River water, The initial optimum biomass and incubation time for initial DOC were induced by variation of nutrient repression and inoculums. The time reached to minimum DOC was selected as incubation time. The initial optimum biomass for Han river water was about 1000~5000 CFU/mL, respectively. In a sufficient biomass, suitable incubation time was about 3~5 day. It was indirectly calculated BDOC on maximum growth rate by measuring growth yield of indigenous bacteria. But it was difficult to adapt growth yield coefficient because of irregular bacterial growth. The measured 3 day BDOC was close to BDOC calculated with our proposed experimental equation between DOC and BDOC. It shows that the quantification of BDOC with this experimental equation can be used indirectly.

  • PDF

A Study on the Mechanical Mechanism According to the Groove Shape of T-welded Joint (T-joint 용접부의 형상에 따른 역학적 메카니즘에 관한 연구)

  • 방한서;김종명
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.53-61
    • /
    • 1999
  • The use of thick plate in increasing in recent years due to the rapid expansion of chemical plants, nuclear plants, ships and other industrial plants. Welding is the most popular joining techniques employed in manufacturing industrial machineries and structures. Normally, Groove shapes are prepared according to appropriate rules and regulations such as KS, JIS, AWS, LR, DNV and etc. for various thicknesses of plate. However those groove angles tend to be too large. As a result of large groove angle, residual stress, deformation of material and strength reduction is obtained. Therefore, the reliability and safety of structures and machinery tend to be decreasing. Therefore, in this paper, theoretical as well as experimental study are carried out to find optimum groove shapes for T-welded joint of mild steel. The test specimen are made in same condition with simulation model. Welding residual stresses measurement by sectional cutting method. ⅰ) The mechanical difference for change the thickness of plate and groove angle are not appeared. ⅱ) In a mechanical point of view minimum preparation angle(40°) is more suitable than maximum groove angle(60℃). ⅲ) The measurement value and distribution of welding residual stresses are not effected largely by groove angle. It is mechanical restraint that mainly affect welding residual stresses distribution. In mechanical point of view minimum groove angle is more suitable than maximum groove angle. Therefore, it is appropriate to minimize the size of groove shape in strength and safety.

  • PDF

A Study on the Measuring Accuracy of Ultrasonic Hardness Tester (초음파 경도계의 측정정도에 관한 연구)

  • Han, Eung-Kyo;Yoon, Jong-Hak;Kim, Jae-Yeor
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 1987
  • In recent days, the application of ultrasonics has been increased in the field of engineering and medicine. The ultrasonic hardness tester to apply the principle of contact compliance method is entirely different from hardness tester in the past and in the practical use, the more pre- cisive measurement is required because it has a slight change of hardness value due to the difference of resonance frequency. Therefore, in this study, as one type of applicative transducers which can detect the optimum pressure load, ring type load cell was used in the measurement of ultrasonic hardness. From experimental results, it was compared ultrasonic hardness testing method with the other hardness testing methods. Also, the measurement error of ultrasonic hardness tester could be measured within .+-. 0.5 HRC F.S. in the case of 3.0Kg pressure load.

  • PDF

Comparative Study on Proposed Simulation Based Optimization Methods for Dynamic Load Model Parameter Estimation (동적 부하모델 파라미터 추정을 위한 시뮬레이션 기반 최적화 기법 비교 연구)

  • Del Castillo, Manuelito Jr.;Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.187-188
    • /
    • 2011
  • This paper proposes the hybrid Complex-PSO algorithm based on the complex search method and particle swarm optimization (PSO) for unconstrained optimization. This hybridization intends to produce faster and more accurate convergence to the optimum value. These hybrid will concentrate on determining the dynamic load model parameters, the ZIP model and induction motor model parameters. Measurement-based parameter estimation, which employs measurement data to derive load model parameters, is used. The theoretical foundation of the measurement-based approach is system identification. The main objective of this paper is to demonstrate how the standard particle swarm optimization and complex method can be improved through hybridization of the two methods and the results will be compared with that of their original forms.

  • PDF