• Title/Summary/Keyword: optimum length

Search Result 1,487, Processing Time 0.036 seconds

Schlieren Visualization of the Thrust Vector Flowfield in a Supersonic Two-Dimensional Nozzle (2차원 초음속 추력편향노즐을 이용한 쉴리렌 가시화 실험연구)

  • Jeong, Han-Jin;Choi, Seong-Man;Chang, Hyun-Soo
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.3
    • /
    • pp.30-37
    • /
    • 2011
  • The thrust vectoring concept has been used for use in new advanced supersonic aircraft. This study presents the performance characteristics of the thrust vectoring nozzle by visualizing the shock behaviors with Schlieren method. The scaled models were designed and manufactured to see the shock behaviors of the various airflow condition. Also we executed experimental tests to see the geometrical effects of the thrust vector nozzle by changing pitch angle and length of pitch flaps. From this study we could understand the supersonic flow characteristics of the thrust vector nozzle. The total thrust of thrust vector nozzle is diminished by increasing the flap angle. But there is an optimum flap length ratio for attaining the highest thrust level and proper pitch effect.

Regeneration Potential of Immature Embryos during Seed Development in Spring and Winter Wheat Genotypes

  • Kim, Kyung-Hee;Park, Ji-Suk;Lee, Byung-Moo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.3
    • /
    • pp.279-283
    • /
    • 2011
  • The immature embryos during seed development were examined to predict the suitable embryos for an efficient regeneration system. Five spring wheat genotypes and five winter wheat genotypes were tested using immature embryos as explants. Spring wheat genotypes showed much higher levels of plant regeneration than those of winter wheat genotypes. The highest frequencies of embryogenesis and regeneration were obtained when embryos at 13-14 days after anthesis (DAA) were used as explant and decreased using embryos at 21-22 DAA during seed development. Significant differences were also found for callus induction and regeneration as affected by immature embryo size. The regeneration efficiency was drastically decreased in spring and winter wheat genotypes when embryos larger than 2.0 mm of length were used. The optimum developmental stage and embryo length for regeneration efficiency were at 13-14 DAA and 1.0-1.5 mm, respectively. The selection of suitable embryos for the high frequencies of embryogenesis and regeneration leads us to efficient genetic improvement of wheat.

The study of the Characteristic of the Coaxial Type Inertance Pulse Tube Refrigerators (관성관형 동축 맥동관 냉동기의 특성에 관한 연구)

  • 김양훈;박성제;홍용주;김효봉;이승홍
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.33-35
    • /
    • 2003
  • There are three types that geometrical arrangement of the pulse tube and regenerator - in line type, U type, and coaxial type. The most compact and convenient one practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. To investigate effects of the inertance tube, we perform experiments with varying inertance tube inner diameter and length. The experimental results show that optimum inertance tube inner diameter and length are 1.3mm, 1900mm respectively.

  • PDF

Buckling and Optimum Reinforcement of Axially Stiffened Cylindrical Shells (보강(補剛) 원통 Shell의 좌굴(挫屈) 및 최적보강(最適補强))

  • Jang, Chang-Doo;Nho, Wan
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.24 no.1
    • /
    • pp.42-50
    • /
    • 1987
  • The energy expressions are formulated for the axially stiffened shell treating the stiffeners as discrete elements. The principle of minimum potential energy is employed to formulate the buckling equations for a simply supported, axially stiffened shell under uniform axial compression. The displacement functions are expended into double trigonometric series. The mode assuming method employed in this paper makes it possible to reduce the matrix size of the eigenvalue problem considerably. Effects are made to investigate the transition from overall buckling to local buckling and to verify the existence of the minimum stiffness ratio of stiffener as in the case of stiffened plate. The results of the calculation show that the critical stiffener size increase linearly as the length of the shell increases. The results also show that the overall buckling load decreases and the local buckling load has a nearly constant value as the length of the shell increases. The results show very good agreements with other computational available.

  • PDF

Effect of Activated Charcoal on Growth of Zingiber mioga ROSC

  • Choi, Seong-Kyu;Yun, Kyeong-Won;Chon, Sang-Uk;Seo, Young-Nam;Seo, Kyoung-Sun;Kwon, Byung-Sun
    • Plant Resources
    • /
    • v.7 no.2
    • /
    • pp.155-158
    • /
    • 2004
  • Activate charcoal (AC) can be utilized as a soil conditioner in agricultural crop areas. This study was conducted to investigate the effect of AC on growth and yield of Zingiber mioga ROSC as affected by different amounts of AC. The results obtained are summarized as follows. Growth characteristics including plant height and leaf length were the highest when activated charcoal added with 10-30%, suggesting that optimum amount of activated charcoal was ranged from 10 to 30%. Growth and enlargement of the root were improved by 10% AC with higher rhizome length and weight.

  • PDF

A Study on the description of Horizontal Geothermal Heat pump Type on Small Residential House (소규모 주택에 대한 수평형 지열 히트펌프 형태 결정에 관한 연구)

  • Yun, Jang-Ryeol;Cho, Sung-Woo;Choi, Jung-Min
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.328-332
    • /
    • 2011
  • The conclusion is derived from the arranged results and using a simulation by determining the shape of an optimum heat pump which is appropriate for small scale houses. It is concluded as 3 meters long for the laying depth of underground piping of the horizontal type geothermal heat pump system in regard to the 5 RT capacity standard that is suitable for a small scale house. The shape of the horizontal type geothermal heat pump system for a small scale house is theThree pipe shape whose trench length is short and pipe length laid in a trench is short. It is 9 for the number of laying pipes that is most appropriate to system.

  • PDF

A Study on the Relationship between the Traffic Signal System and the Air Pollutants emitted by the Motor Vehicles at Intersection

  • Hong, Min-Sun;Woo, Wan-Gi;Park, Jong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.364-372
    • /
    • 1993
  • The purpose of this study is to analyze traffic patterns by use of TRANSYT-7F Model, and to choose the optimum traffic-light cycle length and cycle splite to improve traffic flow and air quality at Samsung Intersection in Seoul. Emission rates of air pollutants are calculated for three time segments 0700-0900, 0900-1800 and 1800-2000. The traffic volume correlated reasonably well with air pollutants emitted ; however, the phasing and timing of traffic signals was found to equally be important. The results of performance with optimal setting indicate that the best cycle length were 80sec(0700-0900), 95sec(0900-1800) and 90sec(1800-2000), res-pectively. As expected the highest emissions of air pollutants were observed during the evening rush hours (1800-2000). A properly designed signalized intersection can help reduce traffic delay, driver discomfort, fuel consumption, and air pollution by efficiently the capacity of existing intersection.

  • PDF

Design Optimization of a Cylindrical Film-Cooling Hole Using Neural Network Techniques (신경회로망기법을 사용한 원통형 막냉각 홀의 최적설계)

  • Lee, Ki-Don;Kim, Kwang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.954-962
    • /
    • 2008
  • This study presents a numerical procedure to optimize the shape of cylindrical cooling hole to enhance film-cooling effectiveness. The RBNN method is used as an optimization technique with Reynolds-averaged Navier-Stokes analysis of fluid flow and heat transfer with shear stress transport turbulent model. The hole length-to-diameter ratio and injection angle are chosen as design variables and film-cooling effectiveness is considered as objective function which is to be maximized. Twelve training points are obtained by Latin Hypercube Sampling for two design variables. In the sensitivity analysis, it is found that the objective function is more sensitive to the injection angle of hole than the hole length-to diameter ratio. Optimum shape gives considerable increase in film-cooling effectiveness.

Optimal Design of Reinforced Rail over Connection Section of Bridge and Embankment (교량/토공 접속구간 보강레일의 최적설계)

  • Yang, S.C.;Kang, Y.S.;Kim, E.
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.256-263
    • /
    • 2002
  • This paper deal with optimal design of reinforced track as a track reinforcing method for transition area of track support stiffness in transition area between bridge and earthwork. When vehicle passes through transition area, dynamic properties between vehicle and track are studied by the analysis of vehicle-train interaction for the each case when reinforced tracks are used or not. furthermore, optimum decision of type and length of track are made based on the performance adapting variable parameters : support stiffness of track for bridge and earthwork, heading direction of vehicle and type and length of track.

  • PDF

Optimum Design of Thermosyphon Solar Hot Water System (자연 대류형 태양열 온수기 최적 설계에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Lee, D.G.;Kang, M.C.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 1998
  • It was compared with experimental data to verify TRNSYS Model of the thermosyphon hot water system and the various simulations were conducted to optimize the component parameters of the system. To obtain consistent simulation results the system model, which could accurately describ the thermal storage tank temperature stratification and the friction head for mass flow rate, was used. The optimization of collector parameters(collector aspect ratio, riser numbers per header unit length), thermal storage tank parameters(ratio of tank length to tank diameter, heat exchanger type), system parameters(ratio of tank volume to collector area) was simulated by TRNSYS program. The simulation results indicate that the system performance is more effected by collector aspect ratio and the ratio of tank volume to collector area than the othor parameters.

  • PDF