• Title/Summary/Keyword: optimum expansion

Search Result 268, Processing Time 0.026 seconds

A Study on the Characteristics of the interface in Tube / Tubesheet of the Nuclear Steam Generator by Explosive Bonding (폭발접합된 원자력 증기발생기 튜브/튜브시트 계면 특성에 관한 연구)

  • 이병일;공창식;심상한;강정윤;이상래
    • Explosives and Blasting
    • /
    • v.17 no.4
    • /
    • pp.32-50
    • /
    • 1999
  • This study deals with interface charactristics of tube and tubesheet of the nuclear steam generator by the explosive expansion in order to take advantage of optimum expansion ratio, pull-out strength and leakage tightness and improvement of the resisitance on the stress corrosion cracking for low residual stress. The paper also show the relationship between roll, hydraulic and explosive expansion. The results obtain are as follows (1) Because of the explosive bonding is to use the high speed pressure and energy by the explosive, workability is good, bonding region is homogenous (2) Expansion ratio is 2.7%, Pull-out strength 850kg, Leakage strength $500kg/cm^2$. Clearance gap is 10~30mm in case of explosive expansion and interface structure of the tube and tubesheet is optimum condition. (3) As the transition region of the explosive expansion is inactive, the resistance of the stress corrosion cracking is increases 30~40% compare to the roll and hydraulic expansion.

  • PDF

Study on Optimum Shape of Expansion Joint (신축조인트의 최적화형상에 대한 연구)

  • Han, Moonsik;Ahn, Junghyun;Yang, Chulho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.154-158
    • /
    • 2013
  • Expansion joint has been utilized in many areas including automotive bellows for exhaust system. Usage of expansion joint has been increased due to its inherent flexibility and excellent anti-vibration property. Simple shape of expansion joint is modeled to understand the behavior of joint system. 27 design cases using 3 design factors with 3 levels are constructed by design of experiment. Each case is simulated to find the most influential design factors. Response for this study, maximum stress in the expansion joint, has been used to determine main design factors of joint. Among the 3 design factors, factor B has affected greatly a response in the formation of optimum shape of joint. Also, interaction factor, $A{\times}B$, has also showed its influence to the response of joint. This study showed that design of experiment combined with finite element analysis could be used in the design decision process effectively in the design of expansion joint.

Analysis of the Operation of a 3 Valve-type Pulse Tube Refrigerator (3 밸브형 맥동관 냉동기의 작동 해석)

  • Song, Young-Shik;Cho, Kyung-Chul;Jung, Pyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.335-340
    • /
    • 2000
  • A 3 valve-type pulse tube refrigerator optains its cooling effect from pressure drop by releasing the part of the charged gas through hot end nozzle. The objective of this study is to analyze the performance and to find an optimal expansion pressure of the 3 valve-type pulse tube refrigerator. It is assumed that gas lumps are not mixed and periodically repeat the adiabatic compression and expansion processes. And the nodal model is applied for the analysis of the regenerator. As the result of analysis, the optimum pressure at the end of expansion process was about 80-90% of the maximum pressure.

  • PDF

Capacity Expansion Models for Optimum Investment Planning (최적(最適) 투자정책(投資政策)을 위한 시설(施設) 확충(擴充)(Capacity Expansion) 모델의 문헌적(文獻的) 고찰(考察))

  • Kim, Seung-Gwon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.11 no.2
    • /
    • pp.141-154
    • /
    • 1985
  • The capacity expansion problem has been defined. Existing literatures on capacity expansion problems have been reviewed and unified under a structure of problem domain. The problem domain has been defined by three relavent coordinates; function or objective of the project, consideration of resource allocation, and consideration of project sequencing. Long range planning is of vital importance in setting up ultimately efficient capital investment plans to meet immediate demand increase. Simplified expansion sequencing example problems have been introduced and solved to help understanding of a solution scheme.

  • PDF

Optimum Design for Inlet and Outlet Locations of Rectangular Expansion Chamber for Improving Acoustic Performance (사각형 단순 확장소음기의 성능향상을 위한 입$\cdot$출구 위치의 최적설계)

  • 김봉준;정의봉;황상문
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.738-746
    • /
    • 1999
  • The performance of muffler can be improved for a frequency range of interest by moving inlet and outlet locations. And optimal location of inlet and outlet can be determined to improve the acoustic performance. The optimum design using FEM, however, may take a very long time and be very hard to take inlet and outlet locations as design variables. In this paper, the acoustic performance of reactive type single expansion chamber muffler is predicted using higher order mode theory. The sensitivity analysis of transmission loss with respect to the location of inlet and outlet is suggested. And the acoustic power transmission coefficient for a frequency of interest is used as cost function. Optimum location of inlet and outlet is determined to minimize cost function by using SUMT algorithm.

  • PDF

Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems (공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성)

  • Kim, J.D.;Jang, J.E.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

Optimum Design for Inlet and Outlet Locations of Circular Expansion Chamber for Improving Acoustic Performance (원형 단순 확장소음기의 성능향상을 위한 입.출구 위치의 최적설계)

  • An, Se-Jin;Kim, Bong-Jun;Jeong, Ui-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2487-2495
    • /
    • 2000
  • The acoustic characteristics of expansion chamber will be changed with the variation of inlet/outlet location due to the higher order acoustic mode in a high frequency in which the plane wave theory is not available. In this paper, the acoustic performance of reactive type expansion chamber with circular cross-section is analyzed by using the modified mode matching theory. The sensitivity analysis of four-pole parameters with respect to the location of inlet and outlet is also suggested to increase the acoustic performance. The acoustic power transmission coefficient is used as cost function, and the location of inlet and outlet is used as design variables. The steepest descent method and SUMT algorithm are used for optimization technique. Several results showed that the expansion chamber with optimally located inlet/outlet had better acoustic performance than concentric expansion chamber.

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

A Study on the Tube/tubesheet Interface in the Heat Exchangers Jointed by Explosive Bonding (폭발접합된 열교환기류 튜브와 튜브시트의 계면 특성에 관한 고찰)

  • 이병일;공창식;이상철
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.38-47
    • /
    • 2000
  • Characteristics of the interface between tube and tube sheet which were formed by explosive expansion and roll expansion, have been studied in the research. The results are as follows: Optimum amounts of explosives for the expansion of Alloy 600 (19.05mm and 15.88mm) were found to be RDX 3.5-8.5g/m. Because explosive expansion caused les strain hardening and increased bounding strength, characteristics of the explosively expanded were better than those of mechanically expanded. As the transition region of the explosive expansion is inactive, the resistance to the stress corrosion cracking increases by 30∼40% compared to the roll and hydraulic expansion.

  • PDF

Characterization of Expanded Tobacco Lamina Tissues by Freeze Drying (냉동건조에 의한 잎담배 팽화특성)

  • 김병구
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.2
    • /
    • pp.149-159
    • /
    • 1995
  • The freeze drying rate was investigated under various conditions such as pressure and moisture contents in order to establish the optimum condition for expansion of the culled flue cured tobacco lamina. The optimal pressure in the chamber to maintain the heat and mass transfer was about 0.8torr, When the moisture contents of sample was 50-60%, expanding rate was the optimum condition and the rate was 67-76%. As the thickness of the sample layers was increased, drying-rate was decreased conversely and this result seemed to be due to decline of heat and mass transfer coefficients. Differences with the position of its stalk were also observed in drying rate, and low stalk position leaves of 5 and 3 was the fastest. Key words : freeze drying, Popping, expansion tobacco.

  • PDF