http://dx.doi.org/10.5916/jkosme.2010.34.2.282

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree  

Beak, Seung-Moon (부경대학교 냉동공조공학과)
Moon, Choon-Geun (주식회사 대일)
Kim, Hyun-Woo (부경대학교 냉동공조공학과)
Jeong, Seok-Kwon (부경대학교 냉동공조공학과)
Yoon, Jung-In (부경대학교 냉동공조공학과)
Abstract
The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.
Keywords
Inverter; Electronic expansion valve; Superheat; Capacity control;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Hua, Li, J. I. Yoon, and S. K. Jeong, "Dynamic characteristics of refrigeration system for control evaporator superheat and cCompressor capacity", The Korean Society for Power System Engineering, KSPSE The 2004 Spring Conference, pp. 170-174, 2004.(in Korean).
2 Y. T. Lee, and Y. C. Kim, "Performance characteristics of an inverter heat pump with various expansion devices", Proceedings of the Air-Conditioning and Refrigeration Engineering 1998 Conference, pp. 8-13, 1998.(in Korean).
3 H. S Yang, H. S. Kim, J. H. Kim, S. B. Kim and J. S. Kim, "Control of refrigerating compressor capacity using inverter", Korean Journal of Air-Conditioning and Refrigeration Engineering, vol. 5 no. 2, pp. 94-101, 1993. (in Korean).
4 D. S. Yang, G. B. Lee and M. S. Kim, and Y. M. Cho "A Study on the capacity modulation of a variable speed vapor compression system using superheat at the compressor discharge", Proceedings of the SAREK 2004 Winter Annual Conference, p. 99, 2004.(in Korean).
5 J. H. Choi, S. M. Baek, B. J. Jin, W. J. Choi, C. G. Moon, H. S. Lee and J. I. Yoon, "Performance characteristics of cooler controled capacity using hot-gas bypass", ICHMT CONV-09 Tunisia, pp. 502-505, 2009.
6 S. M.Beak, J. H. Choi, J. Y. Byun, C. G. Moon, H. S. Lee, S. K. Jeong. J. I. Yoon, "Characteristics of temperature control by hot-gas bypass flow rate on industrial water cooler", The Korean Society of Marine Engineering, vol.33, no. 8, pp. 55-62, 2009.(in Korean).   과학기술학회마을   DOI   ScienceOn