• Title/Summary/Keyword: optimal temperature

Search Result 4,591, Processing Time 0.033 seconds

The Finite Element Analysis and the Geometric Optimal Design of Linear Motor (리니어 모터의 유한요소해석과 기하학적 최적설계)

  • Lee Tae Won;Jung Jae Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.67-74
    • /
    • 2004
  • Linear motor has been considered to be the most suitable electric machine for high speed and high precision linear motion control. Thrust of linear motor is one of the important factor to specify motor performance. Maximum thrust can be obtained by increasing the current in conductor and is relative to the sizes of conductor and magnet. But, the current and the size of conductor have an effect on temperature of linear motor. Therefore, it is practically important to find design results that can effectively maximize the thrust of linear motor within limited range of temperature. Finite element analysis was applied to calculate thrust and numerical solutions were compared with experiment. The temperature of the conductor was calculated by the thermal resistance which was measured by experiment. The optimum design process was coded by the ADPL of ANSYS which is a commercial finite element analysis software. Design variables and constraints were chosen based on manufacturing feasibility and existing products. As a result, it is shown that temperature of linear motor plays an important role in determining optimum design.

Remediation of Diesel Contaminated Soil Using Flowing Subcritical Water (흐름식 아임계수에 의한 경유오염토양의 정화)

  • Li, Guang-Chun;Jung, Sun-Kook;Chung, Seon-Yong;Jo, Young-Tae;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.3
    • /
    • pp.10-16
    • /
    • 2011
  • The experimental studies for remediation of diesel contaminated soils were performed using subcritical water in laboratory scale. Contaminated soils from industrial area and artificially contaminated soils were utilized for soil remediation. Experimental system was composed for subcritical water to flow upward through the soil packed column for extracting contaminants. 10 g of contaminated soil was packed into the column and water flow rate was 2 mL/min. To evaluate the effects of temperature, pressure and treatment time on the removal efficiency, temperature was changed from 100$^{\circ}C$ to 350$^{\circ}C$, pressure from 50 bar to 220 bar and treatment time at the predetermined temperature from 0 min to 120 min. The purification efficiency increased as temperature increased. However, the effect of pressure and treatment time was low. Temperature 250$^{\circ}C$, pressure 50 bar and treatment time 30 min were selected for optimal operating condition for this study.

Effect of Design Parameters and Molding Temperature on Polymethyl Methacrylate Lens Warp (PMMA Lens의 변형에 미치는 설계변수와 금형온도의 영향)

  • Lee, Seon-Ho;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.109-116
    • /
    • 2016
  • Polymethyl methacrylate is commonly used in the outer lens of automotive rear lamps. However, if the lens warps above the allowable limit, it may lead to faulty connection with the housing, and failure of the assembly. This study investigated the effects of gate diameter and cooling line distance in the mold design for automotive outer lens. The optimal gate diameter and cooling line distance to minimize the warp of the outer lens were derived as 3.0 mm and 50-60 mm respectively, and the cooling temperature to minimize warp was shown to be $60-80^{\circ}C$ (mold surface temperature $48-67^{\circ}C$). A higher cooling temperature may somewhat mitigate the warp, but is undesirable because it may cause injection molding problems, such as sinks. A mold was constructed matching the optimal design and the produced lens properties, particularly the degree of warp, were comparable with the CAE predictions.

RABBIT HEATING BY MICROWAVE EXPOSURE AT VARIOUS AMBIENT TEMPERATURES

  • Kolganova, Olga I.;Zhavoronkov, Leonid P.;Petin, Vladislav G.;Kim, Jin-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.99-104
    • /
    • 2010
  • The potential ability of environmental temperature to enhance the effect of microwave radiation (7 GHz) was experimentally studied for rabbit heating after simultaneous application of both agents. The tested ambient temperatures (30 and $38^{\circ}C$) didn't exert a considerable influence upon rabbit heat homeostasis after the used duration of exposure (3 hours and 15 minutes, correspondingly). The synergistic interaction of microwave irradiation and ambient temperature was demonstrated for rabbit heating. Power flux density of microwave irradiation was shown to be a determinant of the synergistic interaction effectiveness. For the fixed ambient temperature ($30^{\circ}C$), the synergism was shown to be observed only within a definite power flux density ($0-100\;mW{\cdot}cm^{-2}$), inside of which there was an optimal intensity ($20\;mW{\cdot}cm^{-2}$), which maximized the synergistic effect. Any deviation of the power flux density from the optimal value resulted in a reduction of the synergy. It is concluded that any assessment of the health or environmental risks should take into account the synergistic interaction between ambient temperature and microwave radiation.

The lyophilization and stability of Salmonella typhi Ty21a (Salmonella thphi Ty21a의 동결 건조와 안정성)

  • 김세란;박동우;전홍렬;김희준;한성순;김기호;김홍진
    • YAKHAK HOEJI
    • /
    • v.43 no.6
    • /
    • pp.793-797
    • /
    • 1999
  • Salmonella typhi Ty21a is an attenuated strain of S. typhimurium and used for oral typhoid vaccine. In an attempt to increase the stability of Ty21a manufacturing typhoid vaccine, we studied about the stability of freeze-dried Th21a including additives at various temperature conditions. In order to investigate the freeze-drying rate of Ty21a according to various absorbance, we lyophilized Ty21a by using 8% sucrose as a stabilizer. The optimal freeze-drying rate of Ty21a was appeared when OD (optical density) value of the growth was between 2.5 and 3.0. To investigate the stability of Ty21a at various temperature, the viability was measured after storaging the freeze-dried Ty21a at the room temperature, cold and freezing condition for 1 week. The viability of Ty21a in cold and freezing storage condition was 5 times more stable than in room temperature. To search the most stable additives for the freeze-dried Ty21a, the viability of Ty21a including additives at the various storage condition was estimated. Mannitol and loctose were the most stable additives. Theses results suggest that the OD value of Ty21a growth, low temperature, mannitol and lactose are important factors for the optimal freeze-drying rate, the stable storage and the most stable additives, respectively.

  • PDF

Can Ambient Temperature Change Affect the Efficacy of Acupuncture on the Postmenopausal Hot Flash? (기온 변화는 폐경후 안면홍조의 침 치료 효과에 영향을 미치는가?)

  • Roh, Jin-Ju;Ahn, Hong-Yup;Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.20 no.4
    • /
    • pp.123-131
    • /
    • 2007
  • Purpose: To find the correlation between ambient temperature change and the efficacy of acupuncture on the postmenopausal hot flash. Methods: 52 patients entered a randomized clinical trial which was to verify the efficacy of acupuncture on postmenopausal hot flash. Participants were treated with optimal/minimal acupuncture in the course of 13 weeks. 34 of 52 visited for the temperature-rising period(Group 1), while 18 of 52 for the temperature-falling period(Group 2), 100mm hot flash VAS and average temperature were taken 18 times from each person. Linear mixed effects model was used to find the correlation between temperature and hot flash VAS score(p-value<0.05). Group1/2, optimal/minimal acupuncture, age, age of menarche, height, weight, percent body fat, BMI, waist-hip ratio, past history of hysterectomy and HRT were also examined. Results: Period of treatment had influence on the hot flash VAS. As time went by, hot flash decreased(p<.0000). Participants who underwent minimal acupuncture showed higher hot flash VAS(p=0.0479) and as waist-hip ratio rose, hot flash increased(p<.0000). As the temperature rose, hot flash VAS score became lower(p=0.0143) and it was because 34 of 52 participants were treated for the temperature-rising period. Group 1/2 had no interrelation with hot flash(p=0.5741). Conclusion: Hot flash diminished as participants were treated with acupuncture, independently of whether the ambient temperature rises or falls.

  • PDF

Finding a Temperature Control Method in Microwave Oven using Genetic Algorithm (Genetic Algorithm을 이용한 전자레인지 온도 최적 제어패턴 구현)

  • 최이존;이승구;임형택;김성현;전홍태
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.98-103
    • /
    • 1995
  • In this paper, a method is presented for finding an optimal temperature control pattern in microwaveoven using genetic algorithm. Power spectrum of temperature variance of charcoal is obtained and oven system modeling with fuzzy-neural-network is explained. Fan on/off timing is converted to strings in gene pool and then genetic iterations make the power spectrum of simmulated temperature variance of microwave oven closer to that o charcoal.

  • PDF

Optimal Design of Resonance Frequency for LLC Converter

  • Chung, Bong-Geun;Moon, Sang-Cheol;Jin, Cheng-Hao
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.159-160
    • /
    • 2015
  • Recently, it is increased to use the portable device with small size. It is also increasing for demand of a small size adapter. To reduce the size of components, switching frequency has to be increased. But it causes higher switching loss and temperature of components. Especially, the temperature of adapter must be limited because adapter can be easily touched when portable device is being charged. To reduce temperature of adapter, high efficiency is essential. To solve this problem, this paper proposes design of resonance frequency optimization for LLC converter with high efficiency and low temperature of passive components.

  • PDF

A Study on the Responsibility of Thin film instantaneous surface temperature probe of a Dual-pipe structure (이중관 구조 박막형 순간온도 프로브의 응답성에 관한 연구)

  • Choi, Seok-Ryeol;Park, Kyoung-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.237-242
    • /
    • 2003
  • The measurement study of instantaneous temperature at combustion chamber wall and the temperature of combustion gas has been under lots of research and development to conclude the temperature process in internal combustion engine for combustion characteristics analysis. The measurement with fast responsibility should be used for temperature measurement inside combustion chamber wall since temperature of wall changes, due to the various gas temperature, irregularly during the combustion. Therefore, thin film instantaneous surface temperature probe, which characterizes the fastest and the most accurate responsibility among contact typed temperature measurement, was used for the experiments. This new thin film instantaneous surface temperature probe improved the problems of noise and durability. The optimal coating thickness of thin film instantaneous surface temperature probe was proven to be $10{\mu}m$ for the best responsibility and durability. It also allowed the stable temperature measurement be taken up to $1,200^{\circ}C$ and proven to be read possibly from the combustion chamber wall.

  • PDF

Optimal Design of Graphite Sheet based Cryogenic Cooler Thermal Control System using Veritrek Software (Veritrek 소프트웨어를 활용한 그라파이트시트 기반 극저온 냉각기 열 제어 시스템 최적설계)

  • Bong-Geon Chae;Hye-In Kim;Hyun-Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.2
    • /
    • pp.71-78
    • /
    • 2024
  • During the initial thermal design process, determining the thermal effect of various design variables in a complex orbital thermal environment is time-consuming. To save time in the initial design phase, it is necessary to quickly derive optimal design parameters and predict the temperature. To address these challenges, Veritrek, a software specialized in optimal design using a reduced-order model (ROM), was released in 2018. In this paper, we utilized the Veritrek software to build a reduced-order model, conduct sensitivity analysis, and perform optimal design analysis for a graphite sheet-based cryogenic cooler thermal control system. The goal was to determine the optimal design values for the number of graphite sheet layers, radiator area, and thickness that would meet the allowable temperature of the cryogenic cooler.