• Title/Summary/Keyword: optimal mixing ratio

Search Result 352, Processing Time 0.028 seconds

Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant (수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구)

  • Oh, S.Y.;Hyun, D.S.;Oh, J.J.;Lee, S.H.;Lee, N.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant (정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석)

  • Song K. S.;Oh S. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.132-137
    • /
    • 2001
  • We used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Code of computational fluid dynamics for numerical analysis was performed using FLUENT, a commercial code. As variable for exactly standardizing, a proper ratio between an outer diameter of deflector and a diameter of pipe, the distance between deflector and orifice, a determination of orifice diameter fur an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Functional Evaluation of Fish Cutlet Batter Made from the Extracts of Hiziki Hizikia fusiformis Fig Fruit Ficus carica and Pear Pyrus pyrifolia (톳(Hizikia fusiformis), 무화과(Ficus carica) 및 배(Pyrus pyrifolia)의 혼합 추출물을 이용한 생선커틀릿용 튀김옷의 기능성)

  • Kim, Min Yong;Kim, Jong Deog;Kim, Bo Yeong;Shin, Young Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.6
    • /
    • pp.721-730
    • /
    • 2017
  • This study determined the optimal mixing ratio of functional materials to enhance the functionality of batter for fish cutlets. An optimal mixing ratio of the hiziki Hizikia fusiformis, fig fruit Ficus carica L. and pear Pyrus pyrifolia Niitaka extracts (HFP extract) of 3:1:1 was found. The physicochemical properties of the mixture were as follows: total phelonic contents of $1187.29{\pm}41.55mg/L$, 1,1-diphenyl-2-picryhydrazyl (DPPH) radical scavenging activity of $61.50{\pm}2.33%$, ascorbic acid content of $23.68{\pm}0.02g/100g$, ${\beta}-carotene$ content of $51{\pm}3.92{\mu}g/100g$, and sugar content of $12.7{\pm}0.1Brix^{\circ}$. A mixture of the extract, Korean herbal powder, and wheat flour was prepared as the fish cutlet batter. The fish cutlet prepared with the batter had a hardness of $166-202g/cm^2$ and Hunter's color scale values L of $31.14{\pm}2.1$ to $34.62{\pm}1.3$, a of $-4.89{\pm}0.21$ to $-2.26{\pm}0.19$ and b of $-20.65{\pm}2.65$ to $28.93{\pm}3.14$. The FRAP (ferric reducing antioxidant power) and VBN (volatile basic nitrogen) of the fish cutlets were measured to evaluate functionality and determine the optimal mixing ratio for cold storage at $-12^{\circ}C$, $-18^{\circ}C$, and $-24^{\circ}C$. The optimum mixture ratio of extracts /Korean herbal powder/ wheat flour was 1:6:3.

The Characteristics of Mortar According to the Water Cement Ratio and Mudflats Replacement Ratio (물-시멘트비 및 갯벌 치환율에 따른 모르타르의 특성)

  • Yang, Seong-Hwan;Lee, Heung-Yeol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.3
    • /
    • pp.227-234
    • /
    • 2017
  • This research analyzes the properties of mortar following the rise in water-cement ratio and applicability as an eco-friendly construction supply by using the mudflats of a dredged arena as a substitute for aggregate. The results of a experiment of the flow showed that the flow value decreases as the amount of mudflats increases. A test for chloride content showed that the chloride content increases with the amount of mudflats. In the compression of specimen mixed with mudflat and the testing of tensile strength, the strength weakened as the addition ratio of mudflats rose. However, with 14-day strength as the standard, most specimen showed more strength than the plain, and 14-day strength was higher than 28-day strength. It appears to be experimental error in the mixing process from the viscosity and cohesion of mudflats, and it is considered that there will be a need for an experiment on mixing methods of mudflats in the future. The compressive strength of this research was the strongest with 70% in water-cement ratio, and the tensile strength was strongest with 80% in water-cement ratio. In the evaluation of surface analysis, 70% water-cement ratio, which is finest in strength, mixing, and compactness, was selected to analyze the roughness of the surface, and the results showed that the surface became smoother as the addition ratio of mudflats increases. In conclusion, it appears that 70% water-cement ratio is the optimal mixing ratio for mortar and 10 to 30% addition ratio of mudflats the optimal ratio. It also appears that the application of interior finishing material like bricks and tiles and interior plastering material using the mudflats are possible.

COD and BOD Removal of Artificial Municipal Wastewater by a Column filled with Zeolite (제올라이트 칼럼에 의한 인공생활하수의 COD 및 BOD 제거에 관한 연구)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.3 no.1
    • /
    • pp.75-89
    • /
    • 2001
  • Constructed wetlands were typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Accordingly, plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. $COD_{cr}$ removal efficiency was 94.63% at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of a zeolite in the diameter range of 0.5 to 1mm to a zeolite in the diameter range of 1 to 3mm. According, hydraulic load $314L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixture were used to determine the optimal mixing ratio by volume of a zeolite(A) in the diameter range of 0.5 to 1mm to a zeolite(B) in the diameter range of 1 to 3mm diameter. 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm. $COD_{cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at filter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate for filter medium of constructed wetland. Removal efficiency was higher in down-flow than in up-flow, and $COD_{cr}$ and BOD were removed best in 20cm filter height near feeding area.

  • PDF

Optimal Design and Test of Fuel-Rich Gas Generator

  • Lee, Changjin;Kwon, Sun-Tak
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.560-564
    • /
    • 2004
  • The optimal design and combustion analysis of the gas generator for Liquid Rocket Engine (LRE) were performed. A fuel-rich gas generator in open cycle turbopump system was designed for 10ton$_{f}$ in thrust with RP-1/Lox propellant. The optimal design was done for maximizing specific impulse of main combustion chamber with constraints of combustion temperature and power matching required by turbopump system. Design variables were selected as total mass flow rate to gas generator, O/F ratio in gas generator, turbine injection angle, partial admission ratio, and turbine rotational speed. Results of optimal design show the dimension of length, diameter, and contraction ratio of gas generator. Also, the combustion test was conducted to evaluate the performance of injector and combustion chamber. And the effect of the turbulence ring was investigated on the mixing enhancement in the chamber.r.

  • PDF

Thermal Durability of Neon Transformer with Diluent Mixing Ratio (증량제 혼합비율에 따른 네온변압기의 열내구성 평가)

  • Hong, In Kwon;Jeon, Gil Song;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.452-457
    • /
    • 2015
  • The physical properties, such as the heat resistance and thermal durability of the temperature difference fatigue resistance should be excellent when preparing an epoxy type resin for a neon transformer housing. In this study, 50 wt% of $SiO_2$ and silica were selected as a reinforcement and diluent filler for epoxy type resins, respectively. Thermal conductivity and thermal stability were measured as the mixing ratio varied upon the particle sizes. The optimal amount of the mixed silica was 50 wt%. Thermal stability was improved with increasing the amount of larger silica particles. The optimal mixing ratio of differently sized silica particles was 28/3 : 14/18 : 8/10 mesh = 1 : 1 : 1. From these results, it is thought that neon transformer is producible which has excellent thermal durability.

Optimized Mixing Design of Carbon-Capturing and Sequestering Activated Blast-Furnace Slag Mortar by Response Surface Analysis (반응표면분석법에 의한 탄소포집 활성 고로슬래그 모르타르의 최적배합 도출에 관한 연구)

  • Jang, Bong Jin;Park, Cheol woo;Kim, Seung Won;Ju, Min Kwan;Park, Ki Tae;Lee, Sang Yoon
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.69-78
    • /
    • 2013
  • PURPOSES : In this study blast furnace slag, an industrial byproduct, was used with an activating chemicals, $Ca(OH)_2$ and $Na_2SiO_3$ for carbon capture and sequestration as well as strength development. METHODS : This paper presents the optimized mixing design of Carbon-Capturing and Sequestering Activated Blast-Furnace Slag Mortar. Design of experiments in order to the optimized mixing design was applied and commercial program (MINITAB) was used. Statistical analysis was used to Box-Behnken (B-B) method in response surface analysis. RESULTS : The influencing factors of experimental are water ratio, Chemical admixture ratio and Curing temperature. In the results of response surface analysis, to obtain goal performance, the optimized mixing design for Carbon-Capturing and Sequestering Activated Blast-Furnace Slag Mortar were water ratio 40%, Chemical admixture ratio 58.78% and Curing temperature of $60^{\circ}C$. CONCLUSIONS : Compared with previous studies of this experiment is to some extent the optimal combination is expected to be reliable.

A Study on the Mix Design and the Control System of Thermal Crack for High Quality Mass Concrete (고품질 매스콘크리트 시공을 위한 배합설계 및 온도균열제어 시스템에 관한 연구)

  • Kim, Sun-Gu;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.174-178
    • /
    • 2001
  • This study was performed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a result, the optimal mixing conditions were : W/B 41%, unit binder 375kgf/$\textrm{m}^3$, FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$\textrm{cm}^2$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps.

  • PDF

A Study on the Mix Design and the Control of Thermal Crack of Mass Concrete (매스콘크리트의 배합설계 및 온도균열제어에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.533-538
    • /
    • 2001
  • This study was peformed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a results, the optimal mixing conditions were : W/B 41%, unit binder 375kg/$cm^{2}$, FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$cm^{2}$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps.

  • PDF