• 제목/요약/키워드: optimal electrode configuration

검색결과 9건 처리시간 0.024초

생체임피던스에 의한 상지운동 감지를 위한 최적 전극 위치의 평가 및 검증 (Evaluation and Verification of Optimal Electrode Configurations for Detection of Arm Movement Using Bio-Impedance)

  • 안선희;김수찬;남기창;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.399-402
    • /
    • 2002
  • In this study, we constructed a four-channel impedance measurement system including a two-channel goniometer to analyze human arm movement. Impedances and joint angles were simultaneously measured for wrist and elbow movements. As the impedance changes resulting from wrist and elbow movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance changes, and minimum interferences in ten subjects (age: 29+6). Our optimal electrode configurations showed very strong relationships between the wrist joint angle and forearm impedance (correlation coefficient = 0.95+0.04), and between the elbow joint angle and upper arm impedance (correlation coefficient = -0.98+0.02). Although the measured impedances changes of the wrist (1.1+1.5 ohm) and elbow (-5.0+2.9 ohm) varied among individuals, the reproducibilities of wrist and elbow impedance changes of five subjects were 5.8+1.8 % and 4.6+1.4 % for the optimal electrode pairs, respectively. We propose that this optimal electrode configuration would be useful for future studies involving the measurement of accurate arm movements by impedance method.

  • PDF

Modeling and performance evaluation of a piezoelectric energy harvester with segmented electrodes

  • Wang, Hongyan;Tang, Lihua;Shan, Xiaobiao;Xie, Tao;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • 제14권2호
    • /
    • pp.247-266
    • /
    • 2014
  • Conventional cantilevered piezoelectric energy harvesters (PEHs) are usually fabricated with continuous electrode configuration (CEC), which suffers from the electrical cancellation at higher vibration modes. Though previous research pointed out that the segmented electrode configuration (SEC) can address this issue, a comprehensive evaluation of the PEH with SEC has yet been reported. With the consideration of delivering power to a common load, the AC outputs from all segmented electrode pairs should be rectified to DC outputs separately. In such case, theoretical formulation for power estimation becomes challenging. This paper proposes a method based on equivalent circuit model (ECM) and circuit simulation to evaluate the performance of the PEH with SEC. First, the parameters of the multi-mode ECM are identified from theoretical analysis. The ECM is then established in SPICE software and validated by the theoretical model and finite element method (FEM) with resistive loads. Subsequently, the optimal performances with SEC and CEC are compared considering the practical DC interface circuit. A comprehensive evaluation of the advantageous performance with SEC is provided for the first time. The results demonstrate the feasibility of using SEC as a simple and effective means to improve the performance of a cantilevered PEH at a higher mode.

생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정 (Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권8호
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

임피던스 방법을 이용한 뇌혈류량 측정기기의 개발( I ) (Development of Rheoencephalograph(I))

  • 김덕원;김정래
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권1호
    • /
    • pp.25-32
    • /
    • 1989
  • In this study, Rheoencephalography( REG ) was designed and constructed. Using the cons- tructed instrument cerebral blood flow(CBF) of left and right brain, CBF change by posture, and reproducibility were studied. Followings are important results. Relative CBF could be measured noninvasively and continuously. Since reproducibility of the constructed REG was found to be quite high (4%), the accuracy of the instrument itself was proved. REG can be easily applied for testing the effect of drugs for the patients with cerebral vessel diseases since it is quite sensitive to the relative changes of CBF. Various cerebral diseases can be diagnosed by analyzing the REG waveforms. The area of restricted cerebral blood vessels can be located by arranging the electrode configuration. Comparative studies with the standard techinques of measuring CBF are needed to verify the accuracy of REG. Further studies on optimal electrode configuration and various artifacts are also necessary.

  • PDF

다구찌법을 이용한 ER 댐퍼의 강건 설계 (Robust Design of an ER Damper using Taguchi Method)

  • 윤영민;배광식;김재환;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.157-162
    • /
    • 2003
  • This Paper presents a robust design of an Electrorheological(ER) damper using Taguchi method. Taguchi method is a robust design method that determines control parameters in the presence of noise effect. Electrode length, electrode gap, base oil viscosity and the weight ratio of ER particles are chosen for the control parameters and the temperature is considered to be a noise factor. The sensitivity of each factor with signal-to-noise(S/N) ratio and analysis of variance are investigated. The analysis results show that the electrode length and base oil viscosity of the ER fluid mostly affect the damping force in the absence of electric field. On the other hand, when the voltage is applied to the ER damper, the electrode length and the weight ratio of ER fluid exhibit significant effect. Based on the Taguchi method, an optimal configuration was designed and the robustness of the designed ER damper was validated by comparing the analysis and experimental results.

  • PDF

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제10권4호
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

가스절연 개폐장치에서 유전율 구배를 갖는 고체 절연물의 형상 최적화 (Shape Optimization of a Permittivity Graded Solid Insulator in a Gas Insulated Switchgear)

  • 주흥진;김동규;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.467-473
    • /
    • 2012
  • A functionally graded material (FGM) spacer, which the distribution of dielectric permittivity inside an insulator changes spatially, can considerably reduce the electric field concentration around a high-voltage electrode and along the gas-insulator interface when compared to a conventional spacer with a uniform permittivity distribution. In this research, we propose the FGM spacer with an elliptical permittivity distribution instead of that with a distribution of dielectric permittivity varying along a radial direction only in order to improve efficiently the insulation capability. The optimal design of the elliptical FGM spacer configuration is performed by using the response surface methodology (RSM) combined with the steepest descent method (SDM).

3차원 유한요소법을 이용한 대전력 트리가트론의 특성 해석 (A 3-D Finite Element Analysis on the Characteristics of High Power Trigatron)

  • 지원영;박정호;주흥진;최승길;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.205-207
    • /
    • 2001
  • This study is characteristic analysis to optimize triggering of a high-power trigatron by FEM which is used to analyse electric field distribution in the trigatron. Triggering characteristics of a trigatron depends on arrangement of voltage polarity applied on electrodes and configuration of electrodes. This study is the preliminary stage for an experiment and make it possible to experiment effectively by finding optimal triggering characteristics though 3-dimensional node-based FEM which can practically model the complex structured electrode system.

  • PDF

연료전지 냉각판의 냉각 특성에 대한 수치해석적 연구 (Numerical Simulation on Cooling Plates in a Fuel Cell)

  • 김윤호;이용택;이규정;김용찬;최종민;고장면
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.86-93
    • /
    • 2007
  • The PEM (polymer electrolyte membrane) fuel cell is one of the promising fuel cell systems as a new small power generating device for automobiles and buildings. The optimal design of cooling plates installed between MEA (membrane electrode assembly) is very important to achieve high performance and reliability of the PEMFC because it is very sensitive to temperature variations. In this study, six types of cooling plate models for the PEMFC including basic serpentine and parallel shapes were designed and their cooling performances were analyzed by using three-dimensional fluid dynamics with commercial software. The model 3 designed by revising the basic serpentine model represented the best cooling performance among them in the aspect of uniformity of temperature distribution and thermal reliability, The serpentine models showed higher pressure drop than the parallel models due to a higher flow rate.