• Title/Summary/Keyword: optical scanning

Search Result 1,613, Processing Time 0.025 seconds

Three-Dimensional Television using Optical Scanning Holography

  • Poon, Ting-Chung
    • Journal of Information Display
    • /
    • v.3 no.3
    • /
    • pp.12-16
    • /
    • 2002
  • We first review a real-time three-dimensional (3-D) holographic recording technique called optical scanning holography (OSH) and discuss holographic reconstruction using spatial light modulators (SLMs). We then present how the overall system can be used for 3-D holographic television (TV) display with a wide-angle view of a 3-D image, and address some of the issues encountered. Finally, we suggest some techniques to alleviate the issues encountered in such a 3-D holographic TV system.

Reconstruction of Optical Scanning Holography with Segmentation

  • Im, Dong Hwan;Kim, Taegeun;Kim, Kyung Beom;Lee, Eung Joon;Lim, Seung Ram
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.680-685
    • /
    • 2021
  • We propose a technique that reconstructs a hologram whose pixel number is greater than the pixel numbers of a conventional image sensor. The pixel numbers of the hologram recorded by optical scanning holography (OSH) increases as the scan area becomes larger. The reconstruction time also increases drastically as the size of the hologram increases. The holographic information of a three-dimensional (3D) scene is distributed throughout the recorded hologram; this makes the simple divide-and-stitch approach fail. We propose a technique that reconstructs the hologram without loss of holographic information. First, we record the hologram of a 3D scene using OSH. Second, we segment the hologram into sub-holograms that contain complete holographic information. Third, we reconstruct the sub-holograms simultaneously. Finally, we rearrange the reconstructions of the sub-holograms.

Development of single optical axis scanning PIV method (단일 광경로 스캔PIV기법의 개발)

  • Kim Hyoung-Bum;Jeong In-Young;Lee Sang-Hyuk;Ryu Chung-Hwan;Jean Hertzberg
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.6-10
    • /
    • 2005
  • PIV(Particle image velocimetry) presents the flow velocity of whole flow fields in a fraction of a second. Conventional PIV method uses two optical axis configuration during the image grabbing process. That is, the illumination plane and the recording plane must be parallel. This configuration is very natural to grab the whole field without the image distortion. In the real problem, it is often to meet the situation which this configuration is hard to be fulfilled. In this study, we developed new PIV method which only uses single optical axis to grab the particle images. This new PIV method become possible by utilizing the scanning method similar to echo PIV technique. One particle image of scanning PIV consists of scanned several line images and by repeating this scanning process, two particle images were grabbed and processed to produce the velocity vectors.

  • PDF

Development of the Scanning PIV Method with Single Optical Axis (단일 광경로 스캐닝 PIV기법 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.181-187
    • /
    • 2007
  • Conventional PIV method uses two optical axis configuration during the image grabbing process. That is, the illumination plane and the recording plane must be parallel. This configuration is very natural to grab the whole field without the image distortion. In the real problem, it is often to meet the situation when this configuration is hard to be fulfilled. In the present study, the new PIV method which uses only single optical axis to grab the particle images is developed. This new PIV method becomes possible by utilizing the scanning method similar to the echo PIV technique. One particle image of the scanning PIV consists of scanned several line images and by repeating this scanning process, two particle images were grabbed and processed to produce the velocity vectors. An optimization study was performed to find parameters which minimize the measurement errors. The effects of particle diameter, beam overlap ratio and particle number density were investigated.

Resolution in Optical Scanning Holography (광스캔닝 훌로그래피의 해상도)

  • Doh, Kyu Bong
    • Journal of Advanced Navigation Technology
    • /
    • v.2 no.2
    • /
    • pp.126-131
    • /
    • 1998
  • In optical scanning holography, 3-D holographic information of an object is generated by 2-D active optical scanning. The optical scanning beam can be a time-dependent Gaussian apodized Fresnel zone plate. In this technique, the holographic information manifests itself as an electrical signal which can be sent to an electron-beam-addressed spatial light modulator for coherent image reconstruction. This technique can be applied to 3-D optical remote sensing especially for identifying flying objects. In this paper, we first briefly review optical scanning holography and analyze the resolution achievable with the system. We then present mathematical expression of real and virtual image which are responsible for holographic image reconstruction by using Gaussian beam profile.

  • PDF

Fast Holographic Image Reconstruction Using Phase-Shifting Assisted Depth Detection Scheme for Optical Scanning Holography

  • Lee, Munseob;Min, Gihyeon;Kim, Nac-Woo;Lee, Byung Tak;Song, Je-Ho
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.599-605
    • /
    • 2016
  • For the implementation of a real-time holographic camera, fast and automatic holographic image reconstruction is an essential technology. In this paper, we propose a new automatic depth-detection algorithm for fast holography reconstruction, which is particularly useful for optical scanning holography. The proposed algorithm is based on the inherent phase difference information in the heterodyne signals, and operates without any additional optical or electrical components. An optical scanning holography setup was created using a heterodyne frequency of 4 MHz with a 500-mm distance and 5-mm depth resolution. The reconstruction processing time was measured to be 0.76 s, showing a 62% time reduction compared to a recent study.

Confocal Scanning Microscopy with Multiple Optical Probes for High Speed 3D Measurements and Color Imaging (고속 3차원 측정 및 칼라 이미징을 위한 다중 광탐침 공초점 주사 현미경)

  • Chun, Wan-Hee;Lee, Seung-Woo;Ahn, Jin-Woo;Gweon, Dae-Gab
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Confocal scanning microscopy is a widely used technique for three dimensional measurements because it is characterized by high resolution, high SNR and depth discrimination. Generally an image is generated by moving one optical probe that satisfies the confocal condition on the specimen. Measurement speed is limited by movement speed of the optical probe; scanning speed. To improve measurement speed we increase the number of optical probes. Specimen region to scan is divided by optical probes. Multi-point information each optical probe points to can be obtained simultaneously. Therefore image acquisition speed is increased in proportion to the number of optical probes. And multiple optical probes from red, green and blue laser sources can be used for color imaging and image quality, i.e., contrast, is improved by adding color information by this way. To conclude, this technique contributes to the improvement of measurement speed and image quality.

  • PDF

Extraction of a Distance Parameter in Optical Scanning Holography Using Axis Transformation

  • Kim, Tae-Geun;Kim, You-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.104-108
    • /
    • 2010
  • We proposed an axis transformation technique which reveals a distance parameter directly from optical scanning holography (OSH). After synthesis of a real-only spectrum hologram and power fringe adjusted filtering, we transform an original frequency axis to a new frequency axis using interpolation. In the new frequency axis, the filtered hologram has a single frequency which is linearly proportional to the distance parameter. Thus, the inverse Fourier transformation of the filtered hologram gives a delta function pair in the new spatial axis. Finally, we extract the distance parameter by detecting the location of the delta function pair.

Simulation of Lens Aberration Correction for Polygon Mirror Scanning (PMS) (Polygon Mirror Scanning (OMS)을 위한 렌즈의 구면 수차 보정 시뮬레이션)

  • 신승연
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1999.08a
    • /
    • pp.128-129
    • /
    • 1999
  • Polygon Mirror Scanning(PMS) is composed of LED array, magnifying lens, polygon mirror and motor. It is important to correct the lens aberrations to gain the image we want to show. In this paper, we have simulated the lens aberration correction to reduce the spherical aberration . We have obtained a aspherical lens which is corrected the spherical aberration.

  • PDF