Browse > Article
http://dx.doi.org/10.3795/KSME-B.2007.31.2.181

Development of the Scanning PIV Method with Single Optical Axis  

Kim, Hyoung-Bum (경상대학교 기계항공공학부)
Publication Information
Transactions of the Korean Society of Mechanical Engineers B / v.31, no.2, 2007 , pp. 181-187 More about this Journal
Abstract
Conventional PIV method uses two optical axis configuration during the image grabbing process. That is, the illumination plane and the recording plane must be parallel. This configuration is very natural to grab the whole field without the image distortion. In the real problem, it is often to meet the situation when this configuration is hard to be fulfilled. In the present study, the new PIV method which uses only single optical axis to grab the particle images is developed. This new PIV method becomes possible by utilizing the scanning method similar to the echo PIV technique. One particle image of the scanning PIV consists of scanned several line images and by repeating this scanning process, two particle images were grabbed and processed to produce the velocity vectors. An optimization study was performed to find parameters which minimize the measurement errors. The effects of particle diameter, beam overlap ratio and particle number density were investigated.
Keywords
PIV; Single Optical Axis; Scanning Method; Synthetic Image;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Anderson, S., Khalitov, D. and Longmire, E., 1999, 'High Spatial Resolution, Stereoscopic PIV Measurements in Fully Developed Turbulent Channel Flow,' PIV3rd, pp. 95-100, Santa Barbara, USA
2 Meng, H. and Hussain, F., 1995, 'In-line Recording and Off-axis Viewing Technique for Holographic Particle Velocimetry,' Applied Optics, Vol. 34, pp. 1827-1840   DOI
3 Kim, H. B., 2004, 'Development of Echo PIV Using Ultrasound Contrast Agent,' Trans. of the KSME(B), Vol. 28, No. 12, pp. 1528-1534   과학기술학회마을   DOI   ScienceOn
4 Kim, H. B., Hertzberg, J. R., Lanning, C. and Shandas, R., 2004, 'Non-invasive Measurement of Steady and Pulsating Velocity Profiles and Wall Shear Stress in Arteries Using Echo PIV: In Vitro Validation Studies,' Ann. Biomed. Eng., Vol. 32, pp. 1067-1076   DOI   ScienceOn
5 Hart, D. P., 1999, 'Super-resolution PIV by Recursive Local-correlation,' J. Visualization, Vol. 10, pp. 1-10
6 Adrian, R. J., 1991, 'Particle-imaging Techniques for Experimental Fluid Mechanics,' Annu. Rev. Fluid Mech., Vol. 23, pp. 261-304   DOI   ScienceOn
7 Okamoto, K., 1999, 'Checker Board Cross-correlation Technique for PIV,' Proc. of PSFVIP-2, Honolulu, No. PF116
8 Willert, C. E. and Gharib, M., 1991, 'Digital Particle Image Velocimetry,' Exp. Fluid, Vol. 10, pp. 181-193   DOI
9 Westerweel, J., Dabiri, D. and Gharib, M., 1997, 'The Effect of a Discrete Window Offset on the Accuracy of Cross-correlation Analysis of Digital PIV Recordings,' Exp. Fluids, Vol. 23, pp. 20-28   DOI