• 제목/요약/키워드: optical particle counter

검색결과 52건 처리시간 0.032초

광학 입자 계수기의 응답특성 및 오계수에 관한 연구 (A Study of Response Characteristics and False Counts in Optical Particle Counter)

  • 안강호;이재헌
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.547-554
    • /
    • 1992
  • 본 연구에서는 Climet사의 백색광원 OPC인 CI226와 PMS사의 laser 광원 OPC인 LAS-X 및 HS-LAS의 응답특성을 측정하여 제작사가 제시한 응답특성과 비교하여 그 정 확성을 논하였으며 아울러 고유량(high flow rate) Clean Room용 OPC인 Climet CI- 7300, Met One 200, Hiac/Royco5120 등 3가지 장치에 관한 오계수의 원인을 박히고자 하였다.

드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정 (Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone)

  • 김희상;박용희;김우영;은희람;안강호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

미세 입자 계수기를 위한 입자 검출 챔버 개발 (Development of Particle Detection Chamber for Particle Counter)

  • 엄우용
    • 전자공학회논문지
    • /
    • 제51권1호
    • /
    • pp.219-224
    • /
    • 2014
  • 본 논문에서는 미세 입자의 크기와 굴절률, 그리고 레이저 파장과 산란광을 얻는 수신단의 각도 등 여러 변수에 대하여 Mie 산란 이론을 적용하여 미세 입자의 산란 특성에 대하여 연구하였고, 이를 바탕으로 미세 입자 검출을 위한 광학계를 구성하고 산란 신호를 획득하여 그 특성을 분석하였다. 그리고 이러한 특성들을 바탕으로 미세 입자 검출기를 위한 입자 검출 챔버를 개발하고 성능을 분석한다.

광학적 입자 계수기를 이용한 ACE-Asia 기간 중 제주 고산에서의 대기 에어로졸 개수 농도 변화 (Change of Atmospheric Particle Number Concentration at Kosan, Jeju using Optical Particle Counter during ACE-Asia)

  • 정창훈;김지영;최병철;오성남
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.435-436
    • /
    • 2001
  • 대기 중 에어로졸 입자의 크기 분포를 측정하는 기기 중 광학적 입자 계수기(Optical Particle Counter)는 0.3$\mu\textrm{m}$에서 25$\mu\textrm{m}$ 사이의 입자의 크기를 개개의 입자에 대한 산란광의 강도를 측정하여 그 강도와 미리 정해진 강도와의 관계에 의해 입자의 크기를 추정한다(Chun et al., 2001). 본 연구에서는 2001년 4월 제주 고산에서 실시된 ACE-Asia(Asian Pacific Regional Aerosol Characterization Experiment) 집중 관측 기간 중 광학적 입자 계수기(Optical Particle Counter; HIAC/ROYCO 5230)를 이용하여 측정한 이 기간 중 에어로졸 입자의 크기 분포의 특성을 황사시와 비황사시, 그리고 강수시와 비강수시로 나누고 그 특징을 비교하여 보았다. (중략)

  • PDF

광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구 (Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter)

  • 송현우;김태욱;송순호
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

The BASF Laser Optical Pitch Particle Counter - Current Applications and Future Developments

  • Champ Simon;Hughes David;Lee Woo-Suk;Esser Anton;Kaub Hans Peter
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.1
    • /
    • pp.73-78
    • /
    • 2006
  • The occurrence of detrimental substances in the paper machine leads to reduced economic performance of paper mills through reduced capacities due to increased paper breaks and cleaning times. In this article the latest generation of BASF's laser optical pitch particle counter is employed in the examination of a paper mill operating two paper machines and using a mixture of thermo-mechanical pulp and recycled fibres. The potential of the new instrument to differentiate between particles on the basis of size and chemical composition is discussed. In addition, direct evidence of the periodic and locational variation of detrimental substances in the paper machine is given. Finally, an example of the application of BASF's laser optical pitch particle counter in the selection of a suitable fixative system for a complex furnish is presented.

  • PDF

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성 (Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC))

  • 정창훈;조용성;이종태
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

습도 변화에 따른 에어로졸의 농도 및 크기의 변화경향 파악 (Change of the Size-Resolved Aerosol Concentration Due to Relative Humidity)

  • 정창훈;박진희;김용표
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.69-78
    • /
    • 2013
  • In this study, the atmospheric aerosol concentration measured at different relative humidity levels was analyzed. Using an optical particle counter, PM10 and PM2.5 concentration as well as particle size distribution were measured and the relation between these size resolved data and relative humidity was studied. The results showed that mass concentration increases as relative humidity increases. The comparison between PM1, PM2.5 and PM10 showed that the fine particles grow more than coarse particles as relative humidity increases. The results also showed that PM10-2.5 and relative humidity do not show close correlation, which means that the mass increase of PM10 at high relative humidity is mainly due to the growth of PM2.5.

Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정 (Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols)

  • 은희람;이홍규;이양우;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.