• Title/Summary/Keyword: optical measuring

Search Result 1,142, Processing Time 0.035 seconds

Enzymatic Method for Measuring ATP Related Compounds in Fish Sauces (효소법에 의한 액젓중의 ATP 관련물질 측정)

  • CHO Young Je;IM Yeong Sun;KIM Sang Moo;CHOI Young Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.4
    • /
    • pp.385-390
    • /
    • 1999
  • HPLC method usually has been used for the determination of ATP and its related compounds in fish muscle and fish sauce. But, total amount of ATP related compounds in fish sauce is determined less than that of fish muscle. In order to establish the extract analysis method for ATP related compounds in fish sauce, a new enzymatic method was developed and compared with existing HPLC method. Fish sauce was extracted with chilled perchloric acid and neutralized to Ph 7.0 with potassium hydroxide solution, the extract was used as sample analyzed by HPLC as usual. On the other hand, for sample analyzed by enzymatic method, 1 ml extract solution was pipetted into test tube. To the tube, 0.5ml of mixed suspension adenosinedeaminase (4U), nucleosidephosphorylase (0.02U) and xanthineoxidase (0.03U) suspended in 2.0ml of 1/15 M sodium phosphate buffer solution pH 7.6 and 1.5ml deionized water wereadded for the decomposition of IMP, HxR and Hx to uric acid at $37^{\circ}C$ for 40 minutes. Total uric acid was determined by measuring optical density at 290nm. In HPLC method, salt decreased the total amount of ATP related compounds by $13.6\~16.2\%$ at $2.5\%$ concentration, but no effect in enzymatic method. IMP, HxR and Hx were detected at 254nm, while uric acid at only 290nm. The ratio of the total amount of ATP related compounds by HPLC method was about $45\%$ of that by enzymatic method in fish sauce. Form these results, enzymatic method is more accurate and simple than HPLC method for analysis of ATP related compounds in fish sauce.

  • PDF

Analysis of the Correlation between Human Sensibility and Physical Property of luminous Sources -Focused on Response according to Character of Color Temperature by luminous Sources- (건축조명광원의 광학적 특성에 따른 인간의 감성반응 분석 -조명광원별 색온도 특성에 따른 반응을 중심으로-)

  • Lee, Jin-Sook;Oh, Do-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this research is to acquire emotional data on luminous source by measuring and evaluating human emotional response to the change of the optical feature of luminous environment Luminous sources used in actual architectural space were selected with the optical feature of luminous soured then to measure and analysis human emotional response on Luminous Source. As a result of that 1) In the result of performance measurement by the item of the clear vision of an optic function the fluorescent lamp of daylight indicated the most excellent Performance. 2) In the item of fatigue and stress, the metal halide lamp and mercury lamp showed the most 3) In $\ulcorner$ suitable in light$\lrcorner$, $\ulcorner$a similar with daylight$\lrcorner$ adjective of the amenity item the fluorescent lamp of daylight which color temperature was high turned up to be high also, in $\ulcorner$brilliant$\lrcorner$, adjective, the metal halide lamp and mercury lamp turned up to be low. 4) In the result of factor analysis, three factors $\ulcorner$activity$\lrcorner$, $\ulcorner$potency$\lrcorner$, $\ulcorner$evaluation$\lrcorner$ were abstracted and $\ulcorner$activity$\lrcorner$ factor has the most influential on evaluating the mood of interior space. 5) For the affection in the mood evaluation by each luminous sources, $\ulcorner$activity$\lrcorner$ factor was the most influential by metal halide lamp and fluorescent lamp of daylight, $\ulcorner$potency$\lrcorner$ factor was most influential by kind of incandescent lamp, $\ulcorner$evaluation$\lrcorner$ factor was most influential by fluorescent lamp of low color temperature.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.

An Experimental Study on Real Time CO Concentration Measurement of Combustion Gas in LPG/Air Flame Using TDLAS (TDLAS를 이용한 LPG/공기 화염 연소가스의 실시간 CO 농도 측정에 관한 연구)

  • So, Sunghyun;Park, Daegeun;Park, Jiyeon;Song, Aran;Jeong, Nakwon;Yoo, Miyeon;Hwang, Jungho;Lee, Changyeop
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.316-323
    • /
    • 2019
  • In order to enhance combustion efficiency and reduce atmosphere pollutants, it is essential to measure carbon monoxide (CO) concentration precisely in combustion exhaust. CO is the important gas species regarding pollutant emission and incomplete combustion because it can trade off with NOx and increase rapidly when incomplete combustion occurs. In the case of a steel annealing system, CO is generated intentionally to maintain the deoxidation atmosphere. However, it is difficult to measure the CO concentration in a combustion environment in real-time, because of unsteady combustion reactions and harsh environment. Tunable Diode Laser Absorption Spectroscopy (TDLAS), which is an optical measurement method, is highly attractive for measuring the concentration of certain gas species, temperature, velocity, and pressure in a combustion environment. TDLAS has several advantages such as sensitive, non-invasive, and fast response, and in-situ measurement capability. In this study, a combustion system is designed to control the equivalence ratio. Also, the combustion exhaust gases are produced in a Liquefied Petroleum Gas (LPG)/air flame. Measurement of CO concentration according to the change of equivalence ratio is confirmed through TDLAS method and compared with the simulation based on Voigt function. In order to measure the CO concentration without interference from other combustion products, a near-infrared laser at 4300.6 cm-1 was selected.

Neutron dosimetry depending on the number of portals for prostate cancer IMRT(Intensity-Modulated Radiation Therapy) (전립선암의 세기조절 방사선치료 시 조사문수별 중성자선량 평가)

  • Lee, Joo-Ah;Son, Soon-Yong;Min, Jung-Whan;Choi, Kwan-Woo;Na, Sa-Ra;Jeong, Hoi-Woun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3734-3740
    • /
    • 2014
  • The aim of this study was provide basic information and establish the criteria in radiation therapy planning by measuring the absorbed neutron dose of normal tissues and lesions according to the number of portals. From September 2013 to January 2014, 20 patients who were diagnosed with prostate cancer and were previously treated with radiation therapy were replanned retrospectively to measure the absorbed neutron dose distribution according to the number of portals. The absorbed neutron dose was measured in each of the 5, 7 and 9 portals using a 15 MV energy, which meant a therapeutic dose of 220 cGy. The optical stimulation luminescence dosimeter was separated by 20cm and 60cm away from the center of the field of view. As a result, the average radiation dose in the abdomen appeared to have a positive relationship with the number of portals, which was statistically significant (p<.05). The average radiation dose was $4.34{\pm}1.08$. The average radiation dose in the thyroid was $2.71{\pm}.37$. Although it showed a positive relationship with the number of portals, it did not have statistical significance. The number of portals and the neutron dose depending on the position showed a significant positive relationship, particularly in the abdomen. As a result of linear regression analysis, as the number of the portal increased in steps, the average volume of the neutrons increased significantly (0.416 times). In conclusion, efficient selection of the number of portals is needed considering the difference in the absorbed neutron dose in the normal tissues depending on the number of the portals.

Inexpensive Visual Motion Data Glove for Human-Computer Interface Via Hand Gesture Recognition (손 동작 인식을 통한 인간 - 컴퓨터 인터페이스용 저가형 비주얼 모션 데이터 글러브)

  • Han, Young-Mo
    • The KIPS Transactions:PartB
    • /
    • v.16B no.5
    • /
    • pp.341-346
    • /
    • 2009
  • The motion data glove is a representative human-computer interaction tool that inputs human hand gestures to computers by measuring their motions. The motion data glove is essential equipment used for new computer technologiesincluding home automation, virtual reality, biometrics, motion capture. For its popular usage, this paper attempts to develop an inexpensive visual.type motion data glove that can be used without any special equipment. The proposed approach has the special feature; it can be developed as a low-cost one becauseof not using high-cost motion-sensing fibers that were used in the conventional approaches. That makes its easy production and popular use possible. This approach adopts a visual method that is obtained by improving conventional optic motion capture technology, instead of mechanical method using motion-sensing fibers. Compared to conventional visual methods, the proposed method has the following advantages and originalities Firstly, conventional visual methods use many cameras and equipments to reconstruct 3D pose with eliminating occlusions But the proposed method adopts a mono vision approachthat makes simple and low cost equipments possible. Secondly, conventional mono vision methods have difficulty in reconstructing 3D pose of occluded parts in images because they have weak points about occlusions. But the proposed approach can reconstruct occluded parts in images by using originally designed thin-bar-shaped optic indicators. Thirdly, many cases of conventional methods use nonlinear numerical computation image analysis algorithm, so they have inconvenience about their initialization and computation times. But the proposed method improves these inconveniences by using a closed-form image analysis algorithm that is obtained from original formulation. Fourthly, many cases of conventional closed-form algorithms use approximations in their formulations processes, so they have disadvantages of low accuracy and confined applications due to singularities. But the proposed method improves these disadvantages by original formulation techniques where a closed-form algorithm is derived by using exponential-form twist coordinates, instead of using approximations or local parameterizations such as Euler angels.

Survey on the Sodium Contents of Nursery School Meals in Gyeonggi-Do (경기도지역 어린이집의 단체급식 중 나트륨 함량 실태조사 연구)

  • Jung, Hong-Rae;Lee, Myung-Jin;Kim, Ki-Cheol;Kim, Jung-Boem;Kim, Dae-Hwan;Kang, Suk-Ho;Park, Jong-Suk;Kwon, Kwang-Il;Kim, Mee-Hye;Park, Yong-Bae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.4
    • /
    • pp.526-534
    • /
    • 2010
  • The prevalence rate for chronic diseases such as obesity, diabetes, hypertension etc. caused by the increment of national income and the change of food life according to the globalization in Korea have been increased. Especially excess sodium intake may contribute to the development of hypertension, increasing cardiovascular disease risk. The objective of this study was to investigate sodium intake of nursery school meals in Gyeonggi-Do, and to construct database for lesser sodium intake policy. Survey consisted of 601 sample intakes of sodium in summer and in winter. A food weighed record method was used for measuring food intakes. Average intakes of ten children per nursery school were measured. The sodium contents of meals were analyzed by ICP-OES (inductively coupled plasma-optical emission spectrometer) after acid digestion by microwave. The sodium contents on food groups showed that sources (693 mg/100 g), grilled foods (689 mg/100 g) and kimchies (643 mg/100 g) had respectively higher sodium contents and the average sodium intake per meal was $582\pm204$ mg. The sodium contents of soups & hot soups and kimchies had 37.5% and 15.8% of total sodium intakes per meal, respectively. Sodium intakes per meal in summer and winter showed 572.3 mg and 592.3 mg, respectively. Regional ranking of sodium intakes showed the ascending order of apartment (514.3 mg/meal), rural region (540.5 mg/meal), multiplex house (635.9 mg/meal) and industrial complex (696.4 mg/ meal). A habit of excessive sodium intakes in childhood will threaten their health when they grow up to be adults; thus lesser intake of sodium per meal is needed for children in nursery school.

MECHANISM IN ANTIBACTERIAL ACTIVITY OF POLYPHOSPHATES AGAINST PORPHYROMONAS ENDODONTALIS (Porphyromonas endodontalis에 대한 Polyphosphate의 항균기전에 관한 연구)

  • Choi, Sung-Baik;Park, Sang-Jin;Choi, Gi-Woon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.561-574
    • /
    • 2000
  • Poly-P has been used to prevent decomposition of foods and has been shown to have inhibitory effect on the growth of gram positive bacteria. The purpose of this study was to evaluate the effect of poly-P on the growth of Porphyromonas endodontalis, a gram negative obligate anaerobic rod, endodontopathic bacterium. P. endodontalis ATCC 35406 was in BHI broth containing hemin and vitamin K with or without poly-P. Inhibitory effect of each poly-P which was added at the beginning(lag phase) or during(exponential phase) the culture, MIC(minimum inhibitory concentration) was determined by measuring the optical density of the bacterial cell at 540nm. Viable cell counts were measured to determined whether poly-P has a bactericidal effect. Leakage of intracellular nucleotides from P. endodontalis was determined at 260nm and morphological change of P. endodontalis was observed under the TEM(transmission electron microscope). Binding of 32P-labeled poly-P to P. endodontalis was examined. SDS-polyacrylamide gel electrophoresis and zymography were performed to observe the changes in protein and enzyme profiles of P. endodontalis, respectively. The results from this study were as follows : 1. The minimal inhibitory concentration(MIC) of poly-P to P. endodontalis appeared to be 0.04~0.05%. 2. Poly-P added to the P. endodontalis culture during the exponential phase of P. endodontalis was as much effective as poly-P added at the begining of the culture, suggesting that the antibacterial effect of poly-P is not much dependent on the initial inoculum size of P. endodontalis. 3. Poly-P are bactericidal to P. endodontalis, demonstrating the decrease of the viable cell counts. 4. Intracellular nucleotide release from the P. endodontalis, was not increased in the presence of poly-P and was not reversed by the addition of divalent cations like $Ca^{2+}$ and $Mg^{2-}$. 5. Under the TEM, it was observed that fine electro-dense materials were prominent in the poly-P grown P. endodontalis, appearing locally in the cell, and the materials were more abundant and more dispersed in the cell as the incubation time with poly-P increased. In addition, highly electron dense granules accumulated in many poly-P grown cells, most of which were atypical in their shape. 6. Binding of 32P-labeled poly-P to P. endodontalis appeared to be 32.8 and 45.5 and 53.4% at 30 minutes, 1 hours and 2 hours, respectively. 7. In the presence of poly-P. the synthesis of proteins with apparent molecular masses of 25, 27, 35, 45 was lost or drastically decreased whereas expression of a protein with an apparent molecular mass of 75 was elevated. 8. Proteolytic activity of P. endodontalis was decreased by poly-P. The overall results suggest that use of poly-P may affect the growth of P. endodontalis, and the anti-bacterial activity of poly-P seems largely bactericidal. Changes in shape, protein expression, and proteolytic activity of P. endodontalis by poly-P may be directly and indirectly attributed to the antibacterial effect of poly-P. Further studies will be needed to confirm the effect of poly-P.

  • PDF

Effect of Chlorella vulgaris CHK0008 Fertilization on Enhancement of Storage and Freshness in Organic Strawberry and Leaf Vegetables (Chlorella vulgaris CHK0008 시비가 유기농 딸기와 엽채소의 저장성과 신선도 향상에 미치는 영향)

  • Kim, Min-Jeong;Shim, Chang-Ki;Kim, Yong-Ki;Park, Jong-Ho;Hong, Sung-Jun;Ji, Hyeong-Jin;Han, Eun-Jung;Yoon, Jung-Chul
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.872-878
    • /
    • 2014
  • This study aimed to enhance storage and freshness of strawberry fruits and foliage vegetables by spray treatment with Chlorella vulgaris as a bio-fertilizer. The tested strain, C. vulgaris CHK0008, was isolated from an organically cultivated rice paddy and identified as C. vulgaris by its morphology and 18S rDNA and 23S rDNA sequence homology. We successfully cultured C. vulgaris CHK0008 in BG11 modified medium (BG11MM) and adjusted $2.15{\times}10^6cell/mL$ C. vulgaris CHK0008 to one OD value by measuring the optical density at 680 nm using a UV-vis spectrophotometer. The soluble solid content of 'Seolhyang' and 'Yukbo' strawberry fruits treated by spray application with C. vulgaris CHK0008 was enhanced by 22.2% and 11.5% respectively, compared to untreated controls. Additionally, the decay rates of treated 'Seolhyang' and 'Yukbo' strawberry fruits decreased 63.8% and 74.4% respectively, compared to untreated control. Surface color changes and chlorosis of leaves in leaf vegetables such as lettuce, kale, red ornamental kale, white ornamental kale and beet were observed in samples treated with water spray for 10 days after cold storage. However, the decay rate of leafy vegetables treated with foliar application of 25% C. vulgaris CHK0008 liquid culture was significantly decreased compared to that of the untreated control during storage at $4^{\circ}C$.

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF