• Title/Summary/Keyword: optical eyes

Search Result 154, Processing Time 0.025 seconds

Gaussian Bracket Expressions of Aplanatic and Achromatic Conditions for Telephoto Type Telescope Objective Derived from the Numerical Solution (Aplanat조건과 Achromatwhrjs의 Gauss괄호 표현과 Telephoto형 망언경 대물렌즈의 설계)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.243-251
    • /
    • 1993
  • We have derived Gaussian bracket expressions of aplanatic and achromatic conditions and obtained the numerical solutions for each of two modules of the telephoto type telescope objective free from the Seidel first order spherical aberration, coma, and longitudinal chromatic aberration. The system which is for use in sighting a target is optimized within the resolution of eyes. The objective lens satisfying the aplanatic and achromatic condition has f/8.5 with the half field angle 0.$3^{\circ}$, and the telephoto ratio is 0.839 with the focal length of 30 cm.

  • PDF

Evaluation of the Natural Quartz with Diamagnetic and Microstructural Characterization (천연수정의 자기적 특성과 미세구조에 의한 품질평가)

  • 송오성;이기영;이정임
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.27-30
    • /
    • 2003
  • Amethyst is a precious stone in Korea. As natural quartz are usually mixed with smoky quartz, amethyst, and milky quartz, we need to evaluate the amount of the amethyst quantitatively in ores. Although the optical evaluation with bare eyes has been common in assay so far, we propose that the diamagnetic property and microstructural difference characterization be the solution for the evaluating the quartz ores. In addition, FTIR (Fourier transformation infra-red) could help to identify the amethyst transparency. We report that we could evaluate the amethyst quantitatively with M-H hysteresis characterization, transmission electron microscopy (TEM) observation and FTIR characterization.

  • PDF

UV Blocking Coatings by Combination of Organic-inorganic Hybrid Materials and UV absorbers (유-무기 하이브리드 재료와 자외선 흡수제의 배합에 의한 자외선 차단 코팅)

  • Yu, Dong-Sik;Lee, Ji-Ho;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1296-1301
    • /
    • 2006
  • The human eye is exposed to UV and visible light. UV light exposure becomes harmful to the eye. Protection for eyes should block all ultraviolet rays. In our study, organic-inorganic hybrid materials have been applied to UV blocking coatings with UV absorbing materials on transparent plastics. The optical properties of UV blocking coatings were investigated in PMMA, CR 39 and PC substrates. In case of all UV absorbers, the transmission of UV light decreases with an increased amount of absorber. Our findings indicate that PMMA significantly reduced the transmission of UV radiation, CR 39 showed moderate decrease, while UV-uncoated PC had some UV blocking properties. Adhesion, hot water resistance and chemical resistance of the UV-coated CR 39 lenses were good. Pencil hardness were 4H. Abrasion resistance were poor.

  • PDF

Voice Activity Detection using Motion and Variation of Intensity in The Mouth Region (입술 영역의 움직임과 밝기 변화를 이용한 음성구간 검출 알고리즘 개발)

  • Kim, Gi-Bak;Ryu, Je-Woong;Cho, Nam-Ik
    • Journal of Broadcast Engineering
    • /
    • v.17 no.3
    • /
    • pp.519-528
    • /
    • 2012
  • Voice activity detection (VAD) is generally conducted by extracting features from the acoustic signal and a decision rule. The performance of such VAD algorithms driven by the input acoustic signal highly depends on the acoustic noise. When video signals are available as well, the performance of VAD can be enhanced by using the visual information which is not affected by the acoustic noise. Previous visual VAD algorithms usually use single visual feature to detect the lip activity, such as active appearance models, optical flow or intensity variation. Based on the analysis of the weakness of each feature, we propose to combine intensity change measure and the optical flow in the mouth region, which can compensate for each other's weakness. In order to minimize the computational complexity, we develop simple measures that avoid statistical estimation or modeling. Specifically, the optical flow is the averaged motion vector of some grid regions and the intensity variation is detected by simple thresholding. To extract the mouth region, we propose a simple algorithm which first detects two eyes and uses the profile of intensity to detect the center of mouth. Experiments show that the proposed combination of two simple measures show higher detection rates for the given false positive rate than the methods that use a single feature.

A Hybrid Approach of Efficient Facial Feature Detection and Tracking for Real-time Face Direction Estimation (실시간 얼굴 방향성 추정을 위한 효율적인 얼굴 특성 검출과 추적의 결합방법)

  • Kim, Woonggi;Chun, Junchul
    • Journal of Internet Computing and Services
    • /
    • v.14 no.6
    • /
    • pp.117-124
    • /
    • 2013
  • In this paper, we present a new method which efficiently estimates a face direction from a sequences of input video images in real time fashion. For this work, the proposed method performs detecting the facial region and major facial features such as both eyes, nose and mouth by using the Haar-like feature, which is relatively not sensitive against light variation, from the detected facial area. Then, it becomes able to track the feature points from every frame using optical flow in real time fashion, and determine the direction of the face based on the feature points tracked. Further, in order to prevent the erroneously recognizing the false positions of the facial features when if the coordinates of the features are lost during the tracking by using optical flow, the proposed method determines the validity of locations of the facial features using the template matching of detected facial features in real time. Depending on the correlation rate of re-considering the detection of the features by the template matching, the face direction estimation process is divided into detecting the facial features again or tracking features while determining the direction of the face. The template matching initially saves the location information of 4 facial features such as the left and right eye, the end of nose and mouse in facial feature detection phase and reevaluated these information when the similarity measure between the stored information and the traced facial information by optical flow is exceed a certain level of threshold by detecting the new facial features from the input image. The proposed approach automatically combines the phase of detecting facial features and the phase of tracking features reciprocally and enables to estimate face pose stably in a real-time fashion. From the experiment, we can prove that the proposed method efficiently estimates face direction.

The Principle of Moving Image and the Development of the Optical Instruments in the 19th Century - On the Theory of Afterimage Effect and the Scientific Development of Moving Image - (동영상의 원리와 19세기 시각기구의 발전과정 - 잔상이론과 동영상의 과학적 발전에 대해 -)

  • LEE, Sang-Myon
    • Korean Association for Visual Culture
    • /
    • v.19
    • /
    • pp.189-221
    • /
    • 2012
  • This thesis investigates the development of optical instruments in the 19th century, before the birth of the cinema, and the principle of the perception of moving images. For this purpose it traces the development stages of the optical instruments which demonstrated 'illusion of movement' from 1820s when the 'persistence of vision' had begun to be researched by scientists. Then, it examines the theory of the 'persistence of vision' or 'afterimage effect' known as the principle in the perception of illusion of movement produced from moving images. The optical instruments in the 19th century that presented the illusion of movement began with the Thaumatrope (double-sided picture disc), and appeared from the Phenakistiscope/Stroboscope (revolving disc), the Zoetrope (revolving drum) and the Praxinoscope (mirror-reflexive revolving drum), and in 1892 the Projection-Praxinoscope presented firstly the moving pictures (animation) on the screen. According to the research of psychology and physiology in the early 20th century it has been recognized that the 'afterimage effect' theory is not sufficient to explain the perception of illusion of movement from the moving images which is closely related to the particularity of the visual perception system of the human eyes. Since then, the Phi-phenomenon suggested 1912 by the Gestalt psychologist, Max Wertheimer (1880-1943), is regarded as the most persuasive theory until now, although it is still imperfect.

Choroidal Thickness in Thyroid-associated Ophthalmopathy between Normal Tension Glaucoma Using Optical Coherence Tomography (스펙트럼영역 빛간섭단층촬영으로 측정한 갑상선 안병증 환자와 녹내장환자의 맥락막 두께 분석)

  • Lee, Bo Young;La, Tae Yoon;Choi, Jin A
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.8
    • /
    • pp.960-967
    • /
    • 2017
  • Purpose: To compare the macular choroidal thickness in patients with thyroid-associated ophthalmopathy (TAO) with those with normal tension glaucoma (NTG). Methods: A total of 70 normal eyes, 74 eyes with TAO and 60 eyes with NTG were enrolled in this study. All patients underwent spectral-domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA, USA). Macular choroidal thickness was assessed using enhanced depth imaging. The average macular choroidal thickness was defined as the average value of three measurements: at the fovea and at the points located 1.5 mm in the nasal and temporal directions from the fovea. Generalized estimating equations were used to uncover factors affecting the average macular choroidal thickness. Results: The average, superior and inferior quadrant retinal nerve fiber layer thicknesses were significantly thinner in the NTG group compared with the TAO and control groups (p < 0.001). The average macular choroidal thickness of the TAO group, NTG group and controls was $281.01{\pm}60.06{\mu}m$, $241.66{\pm}55.00{\mu}m$ and $252.07{\pm}55.05{\mu}m$, respectively, which were significantly different (p = 0.013). The subfoveal, nasal and temporal side choroidal thicknesses were significantly thinner in the NTG group compared with the TAO group (p = 0.014, 0.012 and 0.034, respectively). Subjects with TAO were associated with a thicker average macular choroidal thickness compared with the NTG group after adjusting for age, sex, spherical equivalent and intraocular pressure (${\beta}=32.61$, p = 0.017). Conclusions: Macular choroidal thickness was significantly thicker in patients with TAO compared with those with NTG. Further evaluation is required to determine if a thick choroid in subjects with TAO has any role in glaucomatous optic neuropathy.

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

A study on design of glasses pattern using Optical Art (옵아트를 이용안 안경 패턴 디자인의 연구)

  • Kang, Min-Soo;Kim, In-Soo;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.391-403
    • /
    • 2005
  • Vision is the most important sense of the five senses in our body. This represents that an eye is for the mysterious organ playing the essential role in our body. Alain Mikli known as a famous spectacle designer in France said that glasses exists for seeing and for being seen. This saying is one of the philosophically well-organized definition of the most fundamental function of eye-glasses described in and out of itself. Today, in the world, there are a number of works of glasses design and lots of glasses designers are designing hard in order to convey the goods with the best value and philosophy to customers. They work for the goal that glasses is used as seeing and try to give customers satisfaction and enjoyment of it. And they think that glasses should play the role of the interface. At this point, we need to catch hold of the interface of glasses. That means that glasses has to have the communication between eyes and objects and be the mediation of the connection between the image of oneself and that of one by others. For the character of the interface of glasses, glasses designers should plan and investigate this character at the being of design. This study of optical art has been researched for the necessary and sufficient condition between consumers and products.

  • PDF