• Title/Summary/Keyword: optic

Search Result 2,442, Processing Time 0.027 seconds

Fabrication of a low-power 1×2 polymeric thermo-optic switch with a trench structure (트렌치 구조를 이용한 저전력 1×2 폴리머 열 광학 스위치의 제작)

  • 여동민;김기홍;신상영
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.33-37
    • /
    • 2003
  • A low-power $1{\times}2$ polymeric thermo-optic switch with a trench structure is proposed and fabricated. The trench structure in the optimized region slows down the heat flow from the electrodes, which contributes to the reduction of power consumption. The temperature distribution in the polymer layers has been adjusted to increase the temperature gradient between the two arms of the Y-branch. For comparison, a $1{\times}2$ polymeric thermo-optic switch with no trench structure is fabricated together on the same substrate. In the device with a trench structure, the measured crosstalk is less than -17.0 dB for TE polarization.-15.0 dB for TM polarization. The power consumption is about 66 mW, which is 25% less than that of the device with no trench structure.

Study on Optical Characteristics of pH Indicators in the Immobilized Film for Fiber-Optic pH Sensor (광학적 pH 센서를 위한 지시염료가 고정된 필름의 광학적 특성 연구)

  • Kim, Beom Kyu;Park, Byung Gi
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.414-419
    • /
    • 2017
  • The optical characteristics of cresol red, phenol red, and neutral red immobilized in the thin film were investigated with absorbance measurement in order to find a sensing part of a fiber-optic pH sensor. Sol-Gel method with tetramethyl orthosilicate as a precursor was used to immobilize the pH indicators in the thin film. The absorbance spectra were measured when pH indicators were immobilized in the film and were dissolved in the buffer solution. Experimental results showed that the absorbance spectra could be changed when the pH indicator is immobilized in the thin film. As compared with other pH indicators, the neutral red exhibited similar absorbance spectra regardless of physical conditions and was sensitive over whole pH range between 4 and 11. In addition, the absorbance ratio of base peak to acid peak tended to increase in proportion to the increase in pH. Experimental results indicate that the neutral red is a good pH indicator for fabrication of a sensing part of the fiber-optic pH sensor.

Optimal Design of a MEMS-type Piezoelectric Microphone (MEMS 구조 압전 마이크로폰의 최적구조 설계)

  • Kwon, Min-Hyeong;Ra, Yong-Ho;Jeon, Dae-Woo;Lee, Young-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.269-274
    • /
    • 2018
  • High-sensitivity signal-to-noise ratio (SNR) microphones are essentially required for a broad range of automatic speech recognition applications. Piezoelectric microphones have several advantages compared to conventional capacitor microphones including high stiffness and high SNR. In this study, we designed a new piezoelectric membrane structure by using the finite elements method (FEM) and an optimization technique to improve the sensitivity of the transducer, which has a high-quality AlN piezoelectric thin film. The simulation demonstrated that the sensitivity critically depends on the inner radius of the top electrode, the outer radius of the membrane, and the thickness of the piezoelectric film in the microphone. The optimized piezoelectric transducer structure showed a much higher sensitivity than that of the conventional piezoelectric transducer structure. This study provides a visible path to realize micro-scale high-sensitivity piezoelectric microphones that have a simple manufacturing process, wide range of frequency and low DC bias voltage.

Combined Regional Variant of Guillain-Barre Syndrome with Paralysis of Pupils and Optic neuritis (동공마비와 시신경염이 동반된 길랑-바레 증후군 이형)

  • Lee, Byeung-Yong;Oh, Sun-Young;Seo, Man-Wook;Kim, Young-Hyun;Shin, Byoung-Soo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.60-62
    • /
    • 2002
  • Two separate cranial nerve variants of Guillain-Barre syndrome(GBS) have been reported. One is Miller-Fisher syndrome, the other is polyneuritis cranialis. Involvement of the extraocular muscles in variants of GBS is well recognized, but complete external and internal opthalmoplegia is rare. Optic neuritis remains the only consistent, albeit very uncommon, evidence of inflammation of central nervous system myelin in GBS. This propose that GBS is part of a spectrum of central and peripheral inflammation. This case is an unusual clinical variant who had ptosis, opthalmoplegia, areflexia, ataxia, optic neurritis, marked oropharyngeal, and neck and shoulder weakness. This combined regional from is able to misdiagnose initially as botulism or diphtheria and less so, myasthenia. So if we were consider variant from of GBS, it is possible for make a correct diagnosis more easily and treatment without delay.

  • PDF

Milk Fat Analysis by Fiber-optic Spectroscopy

  • Ohtani, S.;Wang, T.;Nishimura, K.;Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.4
    • /
    • pp.580-583
    • /
    • 2005
  • We have evaluated the application of spectroscopy using an insertion-type fiber-optic probe and a sensor at wavelengths from 400 to 1,100 nm to the measurement of milk fat content on dairy farms. The internal reflectance ratios of 183 milk samples were determined with a fiber-optic spectrophotometer at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$. Partial least squares (PLS) regression was used to develop calibration models for the milk fat. The best accuracy of determination was found for an equation that was obtained using smoothed internal reflectance data and three PLS factors at 20$^{\circ}C$. The correlation coefficients between predicted and reference milk fat at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$ were r=0.753, r=0.796 and r=0.783, respectively. The predictive explained variances ($Q^2$) of the final model, moreover, were more than 0.550 at all temperatures, and the regression coefficients of determination ($R^2$) were more than 0.6 (60%). Our results indicate that milk has different internal reflectance measured in the range of visible and near infrared wavelengths (400 to 1,100 nm), depending on its fat content.

Development of Dynamic Fiber Optic Gyrocompass (동적방식 광섬유자이로 콤파스의 제작)

  • Lee, Seok-Jeong;Choi, Woo-Jin;Bae, Jeong-Chul;Kim, Sung-Jin;Lee, Sang-Sik;Kwon, Yong-Soo;Hong, Tchang-Hee
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.3
    • /
    • pp.67-74
    • /
    • 1997
  • This paper described the method and the result of making a dynamic fiber optic gyrocompass measuring the heading angles of ships by processing the output signal from a constant rotating fiber optic sensor and also showed the measurement to test the performance of our system. Considerig an economical view we designed and ordered a cheap medium grade fiber densors increased not fiber length but the diameter of a fiber sensing loop. The scale factor and noise was 267mV/deg/s and 2 deg/hr/$\sqrt{Hz}(1{\sigma})$, respectively. We made the dynamic fiber optic gyrocompass by this sensor. We measured the heading angles in an arbitrary direction to evaluate the accuracy of our system and the root mean square error was $0.4^\circ$. Moreover, we measured the angles ineach direction of $45^\circ$. successive rotation to know whether this system has distoritions in a specific direction or not and the root mean square error in this case was $0.5^\circ$.

  • PDF

A Study on the Remote Control of Photovoltaic/Solar Heating System according to Seasonal and Regional (계절 및 지역적 특성을 고려한 태양광발전 태양열시스템의 원격제어에 관한 연구)

  • Yoon H.S.;Kang B.B.;Lim J.Y.;Yoon P.H.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.938-941
    • /
    • 2003
  • 본 시스템은 나주 생물자원산업화센터에 설치된 태양광 및 태양열 시스템에 대한 운전결과특성으로써 특용작물배양의 전원 및 온수공급을 위한 것이다 태양광발전은 10kWP이고, 태양열시스템은 500l 로 구성되어 있다. 태양광발전시스템의 인버터는 10kW급 계통연계형으로써 상용전원과 연계해서 사용할 수 있도록 하였으며 태양열시스템은 생물자원산업화센터의 실험용 급탕으로 사용된다. 본 논문에서는 태양광발전과 태양열시스템이 설치된 생물자원산업화센터에 상주 근무인원을 대체하기 위해서 원격 모니터링 시스템을 구성하였고, 모니터링에 의해 축적된 데이터를 통해 그 특성을 비교하고자 한다.

  • PDF

Temperature Dependence of the Electro-optic Characteristics in the Liquid Crystal Display Switching Modes

  • Jeon, Eun-Jeong;Srivastava, Anoop Kumar;Kim, Mi-Young;Jeong, Kwang-Un;Choi, Jeong-Min;Lee, Gi-Dong;Lee, Seung-Hee
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.175-179
    • /
    • 2009
  • As the physical properties of nematic liquid crystals vary with respect to temperature, the performances of liquid crystal displays (LCDs) are highly dependent on temperature. Additionally, it is well known that the electro-optic characteristics of LCDs, such as transmittance and threshold voltage, also rely on the LCD switching modes. The temperature dependence of the electro-optic characteristics of the wide-viewing-angle LCD modes, such as in-plane switching (IPS), multidomain vertical alignment by patterned electrode (PVA), and fringe-field switching (FFS), have been studied, and the results showed that the FFS mode has lower temperature dependence compared to the IPS and PVA modes. Since the liquid crystal (LC) reorients in different ways in each mode, this result is associated with the temperature dependence of LC's bend and twist elastic constants, and also with the position of the main reorientation, either in the middle or on the surface of the LC layer.

Feasibility Study on the Development of Fiber-Optic pH Sensor for Endoscope (내시경용 광섬유 pH 측정 센서 개발을 위한 기초 연구)

  • Lee, Bong-Soo;Hong, Ju-Young;Hwang, Young-Muk;Cho, Seung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.213-217
    • /
    • 2004
  • The general method to find a H. pylori in the stomach is the rapid urease test but it is only used to decide the infection with H. pylori. In this study, it is tried to develope fiber-optic pH sensor which can be used with gastroscop to quantify H. pylori. To measure the degree of infection with H. pylori, the color change of phenol red according to the degree of pH is measured by optical fibers with different light sources and the optimum distance from a sample to the end of sensor tip is decided by measuring the maximum reflectivity from a sample. Also the sensitivity study is carried out to decide the optimum light source which has sensitive change of reflectivity to the change of pH. It is expected that the fiber-optic pH sensor which measures the degree of infection with H. pylori exactly can be developed.

Characteristics of PMN-PZ-PT Thick Film Ceramic by Low-Temperature Sintering Aids (저온 소결 조제에 따른 PMN-PZ-PT 후막 세라믹 특성)

  • Jung, Myungwon;Jeon, Dae-Woo;Kim, Jin-Ho;Lee, Youngjin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.476-482
    • /
    • 2016
  • Convectional PZT based piezoelectric ceramics have to sinter at high temperature about $1,200^{\circ}C$ for their suitable electrical properties. However, some issues: low temperature sintering piezoelectric ceramic composition and reliable internal electrode, have recently attracted a great deal of interest as a highly efficient multi-layered piezoelectric ceramics. In order to optimize low temperature sintering conditions of thick-film PMN-PZ-PT ceramic, it was investigated sintering and piezoelectric properties according to the change of $LiBiO_2$ contents. Thus, the superior piezoelectric properties were found at the pallet type PMN-PZ-PT optimized with low sintering processing at $925^{\circ}C$ including 7 wt% $LiBiO_2$ sintering aid. Consequentially, we successfully manufactured thick-film PMN-PZ-PT ceramics, which had superior piezoelectric and dielectric properties, with 5 wt% of $LiBiO_2$ sintering aid at temperature of $900^{\circ}C$.