• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.027 seconds

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

A Comparative Study on Ophthalmic Lenses Standards (시력 보정용 안경렌즈의 규격 비교 연구)

  • Kwak, Ho-Won;Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.221-228
    • /
    • 2005
  • In order to analyze the difference of lenses production, we measured the refractive power and the thickness of their optical centers using ophthalmic lenses which were distributed at home country and abroad. The home products were manufactured to be next to foreign goods, but there were several cases to exceed acceptable limits and we need to reduce the deviation from measuring values in the same lenses. To get a beat on advanced countries, rearing technical expert, hard quality test and process control and standardization of lenses are essential to home lens industrials.

  • PDF

Anti-reflection Coating using Optical Monitoring System (광학적 모니터링 장비를 이용한 안경렌즈의 무반사 코팅)

  • Jung, Boo-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.159-165
    • /
    • 2011
  • Purpose: In this paper, the reliability and reproductivity of anti-reflection (AR) coating on ophthalmic lens using optical monitoring system (OMS) were investigated. Methods: The random error simulation and RunSheet performance in Essential Macleod software to confirm possibility of AR coating using OMS were performed. The coating process of 19 batches was carried out in order to perform reproductivity test of AR coating after simulation process. Results: As a result, the coating results of 19 batches had shown the excellent reproductivity of about 0.5% error. Conclusions: We confirmed the excellent reproductivity and reliability of AR coating on ophthalmic lens using optical monitoring system from our results.

The Study on the Deficiency Color of the Elementary School (초등학교 아동들의 색각이상에 대한 고찰)

  • Lee, Hak Jun;Kim, Chang Sik;Kim, Hong Gyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.69-72
    • /
    • 1999
  • Testing of color vision by Ishihara's test was followed in 1306 healthy elementary school students from 8 to 13 years old. The number of color deficiency was 27(2.07%) patients who consisted in 25(3.8%) boys among 654(male) and 2(0.31%) girls among 652(female). The male' s patients were definitely more than female's. The type of color deficiency were consisted in 10(37%) patients of red-green anomaly, 7(26%) patients of anomalous trichromatism, 6(22%) patient of red-green anopia and 4(15%) patients who were difficult to classify. All of patients were normal binocular vision and visual acuity.

  • PDF

Preparation and Performance Analysis of Ophthalmic Polymer Using SWCNT and SWCCNT

  • Shin, Su-Mi;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.29 no.12
    • /
    • pp.735-740
    • /
    • 2019
  • The purpose of this study is to fabricate an ophthalmic lens by copolymerizing two types of carbon nanotubes and hydrophilic hydrogel lens materials, and to investigate its application as an ophthalmic lens material by analyzing its physical properties and antimicrobial effect. For polymerization, HEMA (2-hydroxyethyl methacrylate), EGDMA (ethylene glycol dimethacrylate), a crosslinking agent, and AIBN (azobisisobutyronitrile), an initiator, are used as a basic combination, and a single-walled carbon nanotube and a single-walled, carboxylic-acid-functionalized carbon nanotube are used as additives. To analyze the physical properties, the water content, refractive index, breaking strength, and antimicrobial effect of the fabricated lenses are measured. The fabricated lenses satisfies all the basic properties of the basic hydrogel ophthalmic lens. The water content increases with increasing amount of additive and decreases with addition of 0.2 % ratio of nanoparticles. The refractive index is inversely proportional to the water content result. As a result of the antimicrobial test of the fabricated lens, the addition of carbon nanotubes shows an excellent antimicrobial effect. Therefore, it is considered that the fabricated lens can be applied as a functional material for basic ophthalmic hydrogel lenses.

Eye Irritation Test of Lens Washing Agents as ReNuTM (렌즈 보존액 ReNuTM에 대한 안점막자극시험)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong;Joo, Kyung-Bok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.293-304
    • /
    • 2005
  • As the eye irritant test of lens washing agent, ReNu$^{TM}$ was analysed using Draize methods (1959) according to KFDA Guidelines. In addition, to test the potential toxicity of test articles the ratio of inflammatory cells and non-inflammatory epitheloid cells were also observed using smear cytology methods against ocular discharge. At test, the histopathological changes on the cornea, iris, retina and sclera were also observed in all animals. Slight irritancy of the cornea and conjunctiva were observed at 1, 2 and 3 days after dropping in non-washing group. The Mean Index of Ocular Irritation(MIOI) of these points are detected as 4.17, 3.00 and 1.33, respectively. In washing group, slight irritancy of the cornea and conjunctiva were observed at 1 and 2 days after dropping with MIOI as 0.67 and 1.33, respectively. Therefore, ReNu$^{TM}$ was considered as non-irritating materials because the MIOI is detected below 5.00 throughout the whole experimental periods in both washing and non-washing groups. The Index of Acute Ocular Irritation(IAOI) is also detected as 4.17(1 day after dropping). Except of the somewhat increase trend of the inflammatory cell ratios in ocular discharge at 1 day after dropping of non-washing group, but significances are not detected, on the other hand, no meaningful changes on smear cytology of ocular discharges are observed in this study. In addition, no abnormal histopathological changes on the cornea, iris, retina and sclera were also not detected in ReNu$^{TM}$ dropping group compared to that of non-treated control eyes.

  • PDF

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

The Analysis of the State of Successful Refractive Surgery's Eye (성공적인 굴절교정수술자 안구상태분석에 대한 연구)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong;Park, Jeong-Sik
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.223-230
    • /
    • 2014
  • Purpose. Scheduled calibration of refractive error's have various refractive surgery, and a side effect of post refractive surgery for refractive errors's before refractive surgery, by analyzing the eye condition of the refractive error's good state, it tries to increase the satisfaction of refractive error's refractive surgery. Methods. In response to 60 people preoperative data 20-30 generations of age, were analyzed for eye conditions. Results. IOP, thickness of the cornea, liquid leakage amount inspection, the corneal endothelium inspection, the size of the pupil, have been conducted auto refraction test and showed a numerical value in most normal range. Conclusion. Surgery can be of individual differences of patients, it is difficult to define the full normal range, to the surgery based on the case of this study, the side effects of patients after surgery is expected to be prevention.

The Status of Soft Contact Lens Wear in College Students in Korea (한국 대학생들의 소프트 콘택트렌즈 착용에 대한 실태)

  • Kim, Douk-Hoon;Kim, Joung-Suk;Mun, Joung-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.233-239
    • /
    • 2004
  • This study investigated the status of soft contact lens wear in college students. The results were as follows: 1. The most prevalent age of initial contact lens wear was 19 years or 20 years, with an age distribution in females from as early as 10 years to 20 years. 2. For almost all subjects, the test clinic for the contact lens wear assessment and purchase of the contact lenses was an optical shop. 3. The main advantage for most male subjects was use for sports, whereas most female subjects used contact lenses for cosmetic reasons. 4. The most common side-effects experienced due to contact lens wear were red eye, foreign body sensation, and eye pain. 5. The most frequently reported eye disease caused by contact lens wear was conjunctivitis, with only few subjects experiencing keratitis. 6. Following treatment for the side effects of contact lens wear, most subjects hoped to re-use the previous contact lenses, some subjects wanted to change to new contact lenses, and others subjects refused further contact lens wear.

  • PDF

The Need for Change of Korean Optician(optometrist) System (안경사제도의 변화 필요성에 대하여)

  • Seo, Jae-Myoung;Kim, Jae-Do;Kim, Heung-Soo;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.527-536
    • /
    • 2015
  • Purpose: In this paper, we have dealt with problems and improvement of korean optician system. Methods: Using the relevant material of korean optician system and international optometrist system, provides the theoretical basis of the need for regulatory changes optician. Results: The people with refractive errors are increasing, 67% of refractive error test is made from optical shop and korean optician are sufficient trained, many opticians are in charge of the refractive error test at the ophthalmic hospital. We have confirmed that current law does not reflect adequately the nature of optician's work. Conclusions: Since current capacity of the Korean opticians and education system ready to provide health services for people, therefore an korean optician must redefine the law to fit the reality.