• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.028 seconds

A Case of Transpalpebral Enucleation in Shih-tzu with Chronic Unilateral Glaucoma (편측성 만성 녹내장을 지닌 Shih-tzu의 안구적출술 치유예)

  • 정순욱;정월순
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.203-209
    • /
    • 1999
  • A 4-year-old female Shih-tzu with severe episcleral congestion and buphthalmos in left eye was referred to the Veterinary Teaching Hospital, Chonnam National University in October 1998. During two months in local veterinary clinics, the dog had been treated unsuccessfully with tarsorrhaphy and antibiotics. By history taking, cause of the glaucoma was ascertained as accidental nonpenetrated cornea trauma by owner, Ophthalmic examination revealed that the left eye was buphthalmic with severe episcleral congestion, pain and fever. The direct pupillary light response could not be evaluated in the left eye, but right eye had normal reaction. The intraocular pressure was 4.5 mmHg in the right eye and 33 mmHg in the left eye, as measured with a Schiotz tonometer, Ultrasonographic finding revealed hyperechoic vitrous body and central echofree material. The Schirmer tear test showed 20 mm in the left eye and 8 mm in the right eye. The hematologic examination revealed monocytosis. The initial medical treatment was admitted, but there was no response. Transpalpebral enucleation in the left eye under inhalation anesthesia with enflurane 1.2 vol% in oxygen was performed. The day after operation the left eye ravealed no exudate, and pain, and the systemic vital signs were normal. The prognosis is excellent.

  • PDF

A Study on the Simulation Model for Outpatient Waiting Time Reduction (외래환자 대기시간 단축에 대한 시뮬레이션 모델 연구)

  • Chung, Tae Joon;Yoon, Jin Sook;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.3
    • /
    • pp.460-467
    • /
    • 2020
  • The medical service, accompanied by various disease and disease of modern people, must collect various information about patients through various tests, and demand continued to increase. As a result, interest in waiting time for medical services is rising, and various studies are underway to reduce waiting time. However, medical procedure is complex and diverse in the procedure of the services need to be conducted for each procedure. In this study, we are going to propose ways to improve the waiting time of the test procedures that are basically experienced by outpatients through the simulation experimental method. Based on the actual measurement data, the Arena Simulation program was used to implement the hospital's ophthalmic examination model and alternative model. Through this analysis, the waiting time of the examination procedure, the size of the queue, and density of the waiting room were analyzed.

Factors influencing Video Display Terminal Syndrome in Clinical Nurses (임상간호사의 영상표시단말기 증후군 및 영향요인)

  • Kwon, Yunhee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.4
    • /
    • pp.485-494
    • /
    • 2016
  • Purpose: The present research is a descriptive study aimed at understanding clinical nurses' Video display terminal (VDT) syndrome and identifying the factors that affect their VDT syndrome. Methods: Data were collected from 239 clinical nurses working in two metropolitan cities. Research tools included subject's VDT syndrome assessing musculoskeletal, ophthalmic, dermal, psychiatric, and whole body syndromes. The data were analyzed using frequency analysis, average and standard deviation, t-test, One-way ANOVA, and multiple regression analysis with the SPSS/WIN 20.0 program. Results: The subjects' VDT syndrome score was 1.34 out of 5. There were significant differences in participating subjects' VDT syndrome, hospital's size, working unit, health status, diagnosis of illness, having an Order Communication System (OCS), having an Electronic Medical Record (EMR) System, continuous VDT working for more than one hour, break time during VDT use, VDT use time, comfort of the chair, adjustability of the height of the chair, size of the VDT's desk, distance between the monitor and the user's eyes, resolution of the monitor, and frequency of eye exercise during VDT use. According to the research, influencing factors on VDT syndrome in clinical nurses included size of the VDT's desk, frequency of eye exercise during VDT use, having an EMR system, break time during VDT use, diagnosis illness, and having an OCS' system. Conclusion: The findings from this study can be used as a basis for future VDT syndrome prevention education and programs for clinical nurses.

Adaptive Optics in Institute of Optics and Electronics, China

  • Jiang, Wenhan;Ling, Ning
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.3-3
    • /
    • 2000
  • Adaptive Optical (AO) technology can compensate for wave-front errors in real-time to improve image and beam quality. The research and development on AO in China began in 1979. In 1980, the first laboratory on AO in China was established in Institute of Optics and Electronics (IOE), Chinese Academy of Sciences (CAS). Since then several AO systems have been built in this Laboratory. The 19-element system is the first AO system in the world ever used in inertial confinement fusion (ICF) facility in our knowledge. It corrects the static error of this large laser engineering. The 21-element system was firstly tested at the 1.2m telescope of Kunming Observatory in 1990 and then up-dated as an IR AO system installed at the 2.16m telescope of Beijing Observatory. The 37-element system was used with a turbulence cell in Laboratory on Atmospheric Optics in Hefei to conduct elementary research on Atmospheric Optics. The 61-element system for astronomical observation is newly developed. It has been successfully installed at the 1.2m telescope of Kunming Observatory and a laser guide star system will be integrated with the system. A compact AO system using our newly developed miniature DM for high resolution ophthalmic imaging of retina is also being built. The key elements of these AO systems, deformable mirrors and fast-steering mirrors, are all developed in this Laboratory. In this talk, the main configurations of these AO systems, some test results as well as the specifications of these active mirrors will be presented.

  • PDF

Anaphylactic Shock Caused by the Epidurally-Administered Hyalurinidase

  • Lee, Hae-Kwang;Choi, Eun-Joo;Lee, Pyung-Bok;Nahm, Francis Sahngun
    • The Korean Journal of Pain
    • /
    • v.24 no.4
    • /
    • pp.221-225
    • /
    • 2011
  • Hyaluronidase is an enzyme that has temporary and reversible enzymatic effects on the matrix of connective tissue. When added to local anesthetics in pain treatments, it enhances their infiltration and dispersal into tissues. It is widely used in anesthesia for ocular, dental, and plastic surgery. Reports of drug hypersensitivity to hyaluronidase are rare and are usually confined to peribulbar or retrobulbar anesthesia during ophthalmic surgery. However, few reports exist on adverse drug reaction after epidural injection. We have observed two patients experiencing anaphylactic shock caused by hyaluronidase following epidural injection. Most of the patients with a hypersensitivity to hyaluronidase had one previous uneventful injection containing hyaluronidase, implying that sensitization had taken place. However, hypersensitivity occurring at the first administration is possible. A positive skin test can help establish the diagnosis. Although rare, the possibility of an allergic reaction to hyaluronidase should be considered even in patients with no known previous exposure.

The Relationship between Ophthalmic Refractive Errors and Factors of Nutrition and Health (건강 및 식이요인과 굴절이상 시력장애와의 관련성)

  • 김영옥;최혜정;이순영
    • Korean Journal of Community Nutrition
    • /
    • v.5 no.4
    • /
    • pp.608-614
    • /
    • 2000
  • The purpose of this study was to evaluate the relative importance among various biological and environmental factors on refractive errors. Various factors such as diseases, health related behavior such as drinking, smoking and exercise, as well as dietary factors were considered as a possible determinant. Surveys of 492 residents over 20 years of age in Kuri city were conducted during 1998. The survey included a refractive error test adopting a autokerato-refractometer, dietary survey using a 24 hour recall method, disease survey including blood and other diagnosis tests, and a health behavior survey using questionnaires with variables of smoking, drinking, and exercise. A stepwise logistic regression analysis was adopted to analyse the relative importance among independent variables of health behaviors, disease, and dietary factors on ametropias. As a result, in the case of myopia, liver dysfunction appeared to be the most important factors followed by the health related behavior of smoking and exercise as the second most important factors. Nutrient factors such as carotene and protein appeared to be the third most important factors. Similar results had been shown in the case of the hyperopia. In summary, liver dysfunction and the health related behaviors of drinking and smoking appeared to be more influential factors on abnormal eye sight of myopia and hyperopia than dietary factors.

  • PDF

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

A Study of Legibility by Monitor Letter Color with an Eye Tracker (아이트래커를 이용한 모니터 글자 색상에 따른 가독성에 대한 연구)

  • Kim, Ha-Rim;Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Hee-Young;Kim, Young-Gil;Kim, Tae-Hong;Seo, Jae-Myoung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.279-284
    • /
    • 2014
  • Purpose: This study will be a basic research providing data which can reduce eye strain using monitor and electric media by measuring legibility of text color on monitor. Methods: Total experimental subjects who don't have color anomaly and best corrected visual acuity was over 1.0 were 50 and their mean age was $22.83{\pm}1.47$. Reading speed test were carried out with 163 words and subjects who could read over 123 words were selected for legibility examination. Monitor background color was white and letter colors were black, blue, red, and yellow for the legibility examination. Results: In case of text color of black, blue, red, and yellow, Event duration(sec) was measured to 41.89, 42.89, 45.32, and 56.28, respevtively, and reading error (number) was measured to 1.94, 2.74, 3.36, and 5.14. Average of fixation duration(sec) was measured to 0.25, 0.26, 0.27, and 0.32. Conclusions: In this paper, event Duration, reading error and average of fixation duration which can measure the legibility was reduced in a sequence of black blue, red, and yellow.

Marsupialization of the Nictitating Membrane Cyst Following Cherry Eye Repair in a Dog

  • Kim, Sunhyo;Kang, Seon-mi;Susanti, Lina;Kim, Boyun;Park, Yoonji;Shim, Jaeho;Go, Seokmin;Lee, Eunji;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.149-152
    • /
    • 2020
  • One-year-old male Cocker Spaniel dog was referred for the third eyelid enlargement and inflammation in the left eye (OS). It gradually swelled for 2 weeks after the cherry eye repair by conjunctival mucosa pocket procedure at a private animal clinic. Routine ophthalmic examinations including neuro-ophthalmic examination, Schirmer tear test, intraocular pressure and corneal fluorescein staining were all normal. No lesions were found on slit lamp biomicroscopy and indirect ophthalmoscopy except for third eyelid swelling in the OS. Ultrasonography revealed cystic structure within the OS nictitating membrane. Fluid from the cyst was aspirated and there were no microorganisms or neoplastic changes. Surgical intervention was performed under general anesthesia. On the day of the surgery, there was a deep corneal ulcer in the OS, which had not existed before. Ventral palpebral surface of the third eyelid was incised horizontally to the shaft of the T-shaped hyaline cartilage. And then, a full thickness of the cystic wall was incised and marsupialized. Additionally, a direct suture was performed on the ulcerated cornea. Topical and systemic antibiotics and anti-inflammatory drugs were prescribed. One month after the surgery, the third eyelid swelling and the discharge were improved. Marsupialization of the nictitating membrane cyst relieved the swelling of the third eyelid and inflammation. It could be a simple but effective surgical intervention for the cystic complication of conjunctival mucosa pocket procedure in dogs.

Relationships between Reading Ability and Binocular Vision (읽기능력과 양안시기능의 관계성)

  • Kim, Young Ji;Lee, Min-A;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.171-177
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the relationships between reading ability and binocular functions, based on self tests through surveys. The possibility of the reading ability tests used in this study as a tool on the determination about vision efficiency was also evaluated. Methods: Through reading ability tests about 138 university students, 72 students (52.2%) of them were first selected. Through self tests about dyslexia and light sensitivity, 38 students (52.7%) of the first selected students were secondly selected, whose extents are more than 3. Binocular tests were carried out about three groups (high, middle, low) of these secondly selected students. Tests about NPCs, distance and near phoria, amplitude of accommodation, fusional vergence, AC/A ratio, accommodative facility, and vergence facility were performed as binocular tests. Results: NPCs were closest to eyes at high groups. Fusional vergence, AC/A ratio, accommodative facility, and vergence facility of high group showed higher than other groups. The phoria at middle group showed higher than other groups. Conclusions: We found that reading ability and some of binocular functions were closely related. Therefore, vision training, associated with insufficiencies of binocular functions, is expected to improve reading ability.