• Title/Summary/Keyword: ophthalmic lens

Search Result 520, Processing Time 0.023 seconds

Clinical fitting of soft contact lenses

  • Cho-BOptom, Pauline
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.81-91
    • /
    • 2004
  • The use of soft contact lenses for myopia correction is increasing in many countries. It is therefore important for contact lens practitioners to be properly educated in fitting these lenses. Before fitting lenses, it is important to consider the factors and procedures related to soft contact lens fitting, indications and contraindications of fitting soft contact lenses. In this article, the functions and activities involved in preliminary, fitting and delivery consultations will be presented.

  • PDF

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

The Research on the Optical Reliability of Spectacle Lens in Korea (국내 안경렌즈 광학적 요소 신뢰성 조사)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Purpose: This study is to evaluate reliability of geometrical optics properties of spectacle lenses by using ISO and the medical instrument standard of KFDA, which are being sold in Korea. Methods: We used samples of three hundred and ninety eight spectacle lenses of eight company in total. Refractive indices of each samples which were used in experiment were classified into three groups of medium index (1.55~1.56), high index (1.60~1.61) and extra high index (1.67). Results: Conformity of refractive power was 81.61% in total spectacle lenses. The results showed that thickness conformity 90%, appearance conformity 85.18%, size conformity 96.23% and optical center point conformity 99.50% in total. Conclusions: We found that they deviated from the permitting value in many spectacle lenses on refractive power. The results of errors on prism power, surface inspection and optical center point showed small values in total products. In experiment of lens size and thickness, the bulk of indication rates and conformities of samples deviated from the permitting errors.

  • PDF

UV-cut Lens Manufacture using Optical Absorption Edge Control (광흡수단을 제어를 이용한 UV 차단렌즈 개발)

  • Kim, Yong Geun;Park, Dong Hwa;Sung, Jung Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.29-34
    • /
    • 2002
  • Because do dilution (5%) in Venzotriazol distilled water and is kept UV interception departure woe which make to time each 1, 2, 5, 15, 20, 30 minutes by dip method, produced sample ore of UV interception lens. Spectrum of transmittance for each sample are measured in 320~450nm sacred grounds. The result optical absorption edge is each 403, 408, 414, 419nm regions, and absorption edge appeared in each band of 3.07, 3.04, 2.99, 2.96 eV. UV-cut lens departure solution make 2-Hydroxy-4-n-octoxyhenzophenones of 5%, 10% because solvent methanol and UV-cut lens made by Spray pyrolysis method. Transmission edge of each lens that do spray to same warelength showed sameinwavelength spectra. Being storehouse absorption edgethat increase 385, 398 and 417nm region of when do spray for 2, 4 and 6 minutes, band is accomplishing each 3.22, 3.11, 2.97 eV.

  • PDF

Anti-reflection Coating using Optical Monitoring System (광학적 모니터링 장비를 이용한 안경렌즈의 무반사 코팅)

  • Jung, Boo-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.159-165
    • /
    • 2011
  • Purpose: In this paper, the reliability and reproductivity of anti-reflection (AR) coating on ophthalmic lens using optical monitoring system (OMS) were investigated. Methods: The random error simulation and RunSheet performance in Essential Macleod software to confirm possibility of AR coating using OMS were performed. The coating process of 19 batches was carried out in order to perform reproductivity test of AR coating after simulation process. Results: As a result, the coating results of 19 batches had shown the excellent reproductivity of about 0.5% error. Conclusions: We confirmed the excellent reproductivity and reliability of AR coating on ophthalmic lens using optical monitoring system from our results.

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF

Evaluation of Ultraviolet Blocking of Ophthalmic Lenses (안경렌즈의 자외선 차단 평가)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.7-12
    • /
    • 2008
  • Purpose: To evaluate ultraviolet (UV) blocking characteristics of transparent and tinted ophthalmic lenses. Methods: The transmittance spectra of ophthalmic lenses were measured using the method suggested in ANSI Z80.1 standard. Transmittance percentage were calculated for each lens for UV (200~380 nm; UVA, UVB, UVC) and blue light portions (380~400 nm) of spectrum. Results: The results indicate that transparent plastic lenses with middle, high refractive index and tinted plastic lenses had superior UV blocking characteristics at UV radiation while UV blocker-untreated lenses such as crown glasses and CR39 did not. All except high refractive index lenses and anti-glare night vision lens was not effectively blocked blue light. Conclusions: Crown glass and CR39 lenses need to treat UV blockers to protect eyes from UV. Also, all lenes except high refractive index lenses and anti-glare night vision lens need to treat blue light blockers for protecting from blue light.

  • PDF

Design and Fabrication of Sputter Coating System for Ophthalmic Lens (안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구)

  • Park, Moonchan;Jung, Boo Young;Kim, Eung Sun;Lee, Jong Geun;Joo, Kyung Bok;Moon, Hee Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: To design and fabricate the small sputter coating system for the Ophthalmic lens. Methods: The design of sputter target was done using macleod program for AR coating and mirror coating of Ophthalmic lens with Si target and then the sputter system was fabricated. Results: The optimum condition of AR coating with Si target was [air|$SiO_2$(81.3)|$Si_3N_4$ (102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)|$SiO_2$(102)|glass], for blue color mirror coating [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)|$Si_3N_4$(55.4)|$SiO_2$(53.53)|$Si_3N_4$(51.28)|glass], for green color coating [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)|$Si_3N_4$(140.35)|$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass], for gold color [air|$SiO_2$(83.59)|$Si_3N_4$(144.86)|$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass]. Conclusions: In the fabrication of sputtering coating apparatus, Dual cathode with same Ti target were coated at the same time on both sides of Ophthalmic lens to lessen the time of coating on Ophthalmic Lens and save the cost of the lens. The distance of target-substrate of cathode was variable from 12.5 cm to 20 cm. Turbo pump was used to take the whole coating process about 15 min. instead of diffusion pump. The lens holder was made to coat 2 pairs lens every coating and was rotated to get the uniformity of thin film.

  • PDF

Review of the plastic ophthalmic lens (플라스틱 안경렌즈에 관한 고찰)

  • Kim, Sang Yeoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.65-72
    • /
    • 1996
  • The general property of plastic ophthalmic lens has been reviewed by the optical property and polymer structure. A PMMA which is synthesized by the polymerization of monomers of two or more kinds is termed a copolymer, and the main chain composes a skeleton of molecular structure in the polymer. Refraction index of polymer was governed mainly by the polarization of molecular and was followed to increase it conspicuously as Cl, Br, and Iodine was substitude to hydrogen. Thermal dependence of refraction index of polymer show that the higher distinctive characteristic than glass material.

  • PDF