Rotor Initial Polarity Detection Method of Single-Phase PMSM Considering Asymmetric Air-Gap Structure (단상 영구자석 동기 전동기의 비대칭 공극 구조를 고려한 회전자 초기 자극 검출 기법)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Park, Jong-Won;Kim, Yong-Hyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.80-83
    • /
    • 2022
  • This paper proposes an initial rotor polarity detection algorithm of a single-phase permanent magnet synchronous motor (SP-PMSM) related to stable open-loop starting for sensorless operation. Generally, the SP-PMSM needs an asymmetric air-gap structure to can avoid the initial starting failure at zero torque point. Therefore, the rotor polarity information can be obtained by using the DC offset current direction of a stator current through a high frequency voltage injection into an SP-PMSM with an asymmetric air gap. In this paper, the proposed rotor initial polarity detection algorithm is verified through several experimental results.

Two-Dimensional Photonic Crystal Lasers (2차원 광자결정 레이저)

  • Lee, Y. H.;J. K. Hwang;H. Y. Ryu
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.96-98
    • /
    • 2000
  • Room-temperature continuous operation of two-dimensional photonic crystal lasers is achieved at 1.6 ${\mu}{\textrm}{m}$ by using InGaAsP slab-waveguide triangular photonic crystal on top of wet-oxidized aluminum oxide. The main difficulty in the realization of photonic bandgap (OBG) structures has been the nontrivial difficulties in nanofabrication, especially for 3-dimensional PBG structures. Recently, 2-D PBG structures have attracted a great deal of attention due to their simplicity in fabrication and theoretical study as compared to the three-dimensional counterparts [1]. Recently, air-gulfed 2-D slab PBG lasers were reported by Caltech group [2]. However, this air-slab structure is mechanically fragile and thermally unforgiving. Therefore, a new structure that can remove this thermal limitation is dearly sought after for 2-D PBG laser to have practical meaning. In this talk, we report room-temperature continuous operation of 2-D photonic bandgap lasers that are thermally and mechanically stable.

  • PDF

Structure Design and Implementation of AC Servo Motor Control Program (AC 서보모터 제어 프로그램 구조 설계 및 구현)

  • Kyungah Kim;Joon-Young Choi
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.5
    • /
    • pp.209-215
    • /
    • 2023
  • This study proposes an AC servo motor control program structure and its implementation method to efficiently integrate 13 types of additional compensation algorithms into the basic FOC (field-oriented control) algorithm program. Various compensation algorithms are necessary to enhance the stability and performance of machine tools by compensating for interference from disturbances and vibrations. Each compensation algorithm is implemented as a separate, independent function and called from a switch-case statement in the ISR (interrupt service routine) of the PWM (pulse-width modulation) device. The advantages of this approach include facilitating not only debugging and testing but also reducing the possibility of errors during the program development phase. Thus, it is easy to add and activate each specific compensation algorithm for the program update during the program operation phase. The implemented motor control program was experimented with a single-axis feed shaft testbed driven by a commercial AC servo motor control drive board and a 750 Watts SPMSM (surface-mounted permanent magnet synchronous motor), and the results verified its normal operation and performance improvement.

A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs (PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구)

  • 염정덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.6
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

A study on the improvement of floating point operation for AC servo motor controller based on fixed point DSP (고정소수연산 DSP 기반 AC 서보모터 제어기의 소수연산 개선에 관한 연구)

  • Hwang, In-Sung;Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.43-45
    • /
    • 2004
  • This paper represents the improvement of floating point operation for AC servo motor controller based on fixed point operation DSP. TMS320F2812 has fixed point operation processing structure. The controller parameters are modified to the digitized data by scaling the original parameters. TMS320F 2812 is a 32-bit processor, and it could have enough accuracy to get the digitized data this procedure is implemented and the experiments controling a AC servo system.

  • PDF

A study on application plan of driver assistance system for railway energy efficiency (철도에너지 효율화를 위한 운전자 지원시스템 적용방안 연구)

  • Kim, Young-Kyu;Park, Se-Young;Ko, Young-Ho;Nam, Hui-Bok;Han, Moon-Sub
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.171-176
    • /
    • 2010
  • Railway has recently played an important role in preventing global warming caused by green house gases and furthering a low carbon green growth, The various railway research centers have conducted facilitated studies on saving energy. In particular, urban railway has emerged as the best means of public transportation in terms of punctuality, safety and environmentally friendliness. There are various ways to save energy in terms of operation of urban railway system, and they can be generally divided into hardware aspects that pertain to structure of vehicles and development of control system and software aspects that pertain to effective operation of trains based on operation patterns and diagram control. In this paper, we investigated drive assistance system for railway energy efficiency. The railway operation patterns and train diagram management programs were researched.

  • PDF

Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter (비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어)

  • Lee, Hae-Chun;Park, Tae-Yeol;Kim, Gi-Taek
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

Verification of System using Master-Slave Structure (M-S 기법을 적용한 System Operation의 동작 검증)

  • Kim, In-Soo;Min, Hyoung-Bok;Baek, Chul-Ki;Park, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1963-1964
    • /
    • 2008
  • Scan design is a structured design-for-testability technique in which flip-flops are re-designed so that the flip-flops are chained in shift registers. We propose a new technique to re-design about clock operation. This technique propose about low power operation of scan clock and saved time of test operation.

  • PDF

A study on SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system

  • Lee Seung Ryul;Kim Jong Yul;Yoon Jae Young
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.47-51
    • /
    • 2005
  • This paper is for studying the feasibility of SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system. All Korean 154kV power systems are constructed as loop systems in downtown. However, the present 154kV systems are operated with separated systems around 345kV S/S because of fault current and overload problems. In this study, we investigate the structure and operation of 154kV power system in Seoul and study the feasibility of interconnection operation of 154kV systems under 345kV systmes by applying SFCLs to 154kV bus-tie.

A study on behavior of lateral-vibration about Railway truss bridge (철도트러스 교량의 횡진동 특성에 관한 연구)

  • Yoo Seoung-Hun;Cho Sun-Kyu;Oh Ji-Taek
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.916-921
    • /
    • 2004
  • At present, the highest operation speed of general domestic train is in the level of 140km/h and it is being improved to reach at the level of 200km/h in 2011. The improved environment of train operation speed which inevitably occurs owing to the operation of KTX on the existing line badly requires technology development such as testing and evaluating technology of factors hindering high speed of railway infrastructure including railway bridge, technology to ensure operation safety and technology to evaluate structure stability. Comparing dynamic numerical interpretation for railway truss bridge and load of design standard by using dynamic response measurement and analysis for the railway truss bridge currently in use, this study established the improvement program to ensure the lateral dynamic safety of truss bridge with the increased speed of train.

  • PDF