• Title/Summary/Keyword: operation room

Search Result 874, Processing Time 0.026 seconds

The Effect of Preceptorship on OJT(On the Job Training) of New Nurses (신규간호사 배치후 교육시 프리셉터쉽 적용 사례연구)

  • Kim, Chang Hee;Kim, Hae Suk;Cho, Hae Sung;Lee, Soon Ohk;Ham, Hyeong Mi;Park, Mi Mi
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.546-559
    • /
    • 2000
  • The purpose of this study was to examine the effect of preceptorship on On the Job Training of new nurses. The research design was a retrospective survey and one group pre-post test design. The subjects were 49 entry nurses and 49 preceptors. The data were collected from Feburary 1, 1998 to December 1, 1998. One questionnair applied in this study consisted of general characteristics, the responses of new entry nurses and their preceptors and their qualities. The other questionnair consisted of job satisfaction of new entry nurses and preceptors and their competencies. The data were analyzed for frequencies, mean score, standard deviation, t-test, and ANOVA. The results of the study were as follows: 1) Preceptees's responses were that the nurses' affiliation of unit, cooperation of other nurses, and competencies of nursing skills improved after OJT applied preceptorship. 2) Preceptors's answers were that preceptorship had a positive effect on their continuing education. 3) While preceptees's job satisfaction scores were high in interaction, administration, and organization, they were low in autonomy and pay. 4) Pre-competency scores were the same as post-competency scores. 5) After preceptorship, preceptors responded that their nursing skill & communication competency increased, but their nursing administration competency decreased. 6) Finally, preceptorship's other effects were as follows: (1) Checklists for preceptee education at the nursing unit were developed separately. (2) It was proved that 'preceptor interview note' was effective on manage preceptorship. (3) We obtained duty overlap periods; medicalsurgical units-1 month, 5 ICU-2 months, operation room-3 months. (4) We prepared a preceptor program based on the study results.

  • PDF

Design and Implementation of PC Management System using SNMP (SNMP를 이용한 PC 관리 시스템의 설계 및 구현)

  • Joe, Kyu-Oak;Ahn, Sung-Jin;Chung, Jin-Wook
    • Journal of The Korean Association of Information Education
    • /
    • v.3 no.1
    • /
    • pp.86-93
    • /
    • 1999
  • In this paper, we have designed and implemented that PC management system has the function of monitoring and controlling system management MIB defined for PC management using SNMP in PC room. System management MIB consists of monitoring MIB for system and processor information and controlling MIB for backup and restoration. For this, we have added new defined MIB variables to standard MIB and displayed system information, processor information, backup and restoration information of managed PC. And the structure between management system and managed system is shown and process of system information, processor information, backup and restoration of managed PC is illustrated. On real environmental, by monitoring window version, CPU type, system memory and virtual memory and performing backup and restoration of managed PC, actual operation is tested. Management system gathers system information and processor information from managed system and performs backup and restoration for recovering fault of managed system. Hence PC managers can operate and manage many PCs on LAN, efficiently.

  • PDF

A Study on the Management of Performance Rating System in Nursing Organization (간호조직내 인사고과제도운영에 관한 고찰)

  • Ha, Na-Sun
    • The Korean Nurse
    • /
    • v.31 no.5
    • /
    • pp.53-64
    • /
    • 1992
  • A nurse is give much weight in the professions of hospital.The effective achievement of a goal of hospital organization needs to get nurses to contribute the structure positively through the rational personnel management of the nurses.The operation of performance rating system is necessary to improve because the nurses hold negative opinions about the resonable management of that system in most Korean hospitals.Therefore, the prupose of this research was to suggest an efficient method to solve the problem in connection with the management of nurses performance rating system.The results of the study are summarized as follows.1. As the performance rating implies the evaluation of employee's functional accomplishment and ability, and essential condition of the job was surveyed according to the job analysis of nursing activities and nurse position.That is to say, Nusrses' performances and capability is estimated in comparision with the condition of the job. 2. It is required adequacy for evaluation factors in performance rating.That is, $\circled1$ as for those who work in psychiatry or newborn baby room they should be appraied in terms of different factors from those applicable to whom work in a general staffs. $\circled2$ Evaluation factors should be concrete so that the quality and quantity of work and the potential ability of them can be correctly appraised. 3. In order to realize the object of perfamance rating system, the training on chief nurses are quite important. Also, careful practices and continuous supplementary training are required before the system is introduced.First of all, the appropriate evaluation can be mad by continuing to record the rating objects every day for the purpose of obtaining the objectivity of rating. 4. In course of transfering of the position and training, the induction of self-rating system and presentation of self-description is required to supplement functionally the performance rating system. 5. For the efficiency of nurses' performance rating system, the results of performance rating system must be reflected in promotion, allocation and training course, which makes the nurses have the motives and the organization accomplish the goal of modern nursing through its activation.

  • PDF

Remote control by mobile and Labview (휴대폰과 Labview를 활용한 원격제어)

  • Park, Sang-Gug
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.797-801
    • /
    • 2008
  • This paper describes technical method about remote control and monitoring of local system by use personal mobile device in anytime and anywhere. Therefore, the user don't need to stay in operation room of local system. The PC server environment for the mobile connection are constructed with Apache web server, PHP and MySQL ODBC. The mobile internet homepage for the remote mobile connection is designed by Anybuilder software and mobile simulator, Openwave SDK 6.2 is used for the development. The mobile internet program can be applicate to all of domestic communication companies LGT, SKT and KTF. We use KTF mobile contains WAP browser for the test. We used NI Labview software to control and monitoring of local system. The local system, which will be controlled remotely have constructed with analog/digital signal acquisition device, signal control board and their software. By experiments, we confirmed remote control by mobile device are possible.

  • PDF

Development of VR Monitoring System for Gas Plant (가상현실을 이용한 가스플랜트의 VR Monitoring System 개발)

  • Seo, Myeong-Won;Jo, Gi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.5
    • /
    • pp.788-796
    • /
    • 2001
  • VR(Virtual reality) technologies have given engineers the ability to design, test, and evaluate engineering systems in a virtual environment. The virtual plant is the highlight of the application of the VR technology to plant engineering. Plant design, maintenance, control, management, operation are integrated in the virtual plant. The VR monitoring system including the concept of the virtual plant is developed to replace a current control room that has number of gages and warning lamps in two-dimensional panels which shows the operating status of a plant. The operating status of the plant is displayed in the VR monitoring system through the realistic computer graphics. Sophisticated, realistic and prompt control becomes possible. The VR monitoring system consists of advanced visualization, walk-through simulation and navigation. In the virtual environment, a user can navigate and interact with each component of a plant. In addition, the user can access the information by just clicking interesting component. The VR monitoring system is operated with various modules, such as (1) virtual plant constructed with Graphic Management System (GMS), (2) Touch & Tell System, and (3) Equipment DB System of Part. In order to confirm the usefulness of the VR monitoring system, a pilot gas plant which is currently being used for plant operator training is taken as application. The end of the paper gives an outlook on the future work and a brief conclusion.

Flexible and Transparent CuO/Cu/CuO Electrodes Grown on Flexible PET Substrate by Continuous Roll-to-roll Sputtering for Touch Screen Panels Cells

  • Kim, Dong-Ju;Kim, Han-Ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.217.2-217.2
    • /
    • 2014
  • We prepared a flexible and transparent CuO/Cu/CuO multilayer electrodes on a polyethylene terephthalate (PET) substrate using a specially designed roll-to-roll sputtering system at room temperature for GFF-type touch screen panels (TSPs). By the continuous roll-to-roll sputtering of the CuO and Cu layer, we fabricated a flexible CuO(150nm)/Cu(150nm)/CuO(150nm) multilayer electrodes with a sheet resistance of $0.289{\Omega}/square$, resistivity of $5.991{\times}10^{-23}{\Omega}-cm$, at the optimized condition without breaking the vacuum. To investigate the feasibility of the CuO/Cu/CuO multilayer as a transparent electrode for GFF-type TSPs, we fabricated simple GFF-type TSPs using the diamond patterned CuO/Cu/CuO electrode on PET substrate as function of mesh line width. Using diamond patterned CuO/Cu/CuO electrode of mesh line $5{\mu}m$ with sheet resistance of 38 Ohm/square, optical transmittance of 90% at 550 nm and an average transmittance of 89% at wavelength range from 380 to 780 nm, we successfully demonstrated GFF-type touch panel screens (TPSs). The successful operation of GFF-type TPSs with CuO/Cu/CuO multilayer electrodes indicates that the CuO/Cu/CuO multilayer is a promising transparent electrode for large-area capacitive-type TPSs due to its low sheet resistance and high transparency.

  • PDF

Micromirrors Driven by Detached Piezoelectric Microactuators For Low-voltage and Wide-angle Rotation (저전압 대회전을 위한 분리된 압전 구동기에 의한 미소거울)

  • Kim, Sung-Jin;Jin, Young-Hyun;Lee, Won-Chul;Nam, Hyo-Jin;Bu, Jong-Uk;Cho, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.149-155
    • /
    • 2006
  • This paper presents a torsional micromirror detached from PZT actuators (TMD), whose rotational motion is achieved by push bars in the PZT actuators detached from the micromirror. The push bar mechanism is intended to reduce the bending, tensile and torsional constraints generated by the conventional bending bar mechanism, where the torsional micromirror is attached to the PZT actuators (TMA). We have designed, fabricated and tested prototypes of TMDs for single-axis and dual-axis rotation, respectively. The single-axis TMD generates the static rotational angle of $6.1^{\circ}$ at 16 VDC, which is 6 times larger than that of single-axis TMA, $0.9^{\circ}$. However, the rotational response curve of TMD shows hysteresis due to the static friction between the cover and the push bar in the PZT actuator. We have shown that 63.2% of the hysteresis is due to the static friction caused by the initial contact force of the PZT actuaor. Without the initial contact force, the rotational response curve of TMD shows linear voltage-angle characteristics. The dual-axis TMD generates the static rotational angles of $5.5^{\circ}$ and $4.7^{\circ}$ in x-axis and y-axis, respectively at 16 VDC. The measured resonant frequencies of dual-axis TMD are $2.1\pm0.1$ kHz in x-axis and $1.7\pm0.1$ kHz in y-axis. The dual-axis TMD shows stable operation without severe wear for 21.6 million cycles driven by 16 Vp-p sinusoidal wave signal at room temperature.

The suture method using ribbon shaped knot in pediatric facial lacerations (소아 안면 열상 시 리본 모양 매듭법을 이용한 봉합법)

  • Sung, Hyoung Woo;Kim, Jin Woo;Shin, Han Kyung;Jung, Jae Hak;Kim, Young Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.122-125
    • /
    • 2009
  • Purpose: Stitching out in facial simple laceration on children, we use No.11 blade. But the procedure is technically demanded to take care of the uncooperative pediatric patient. When we suture a laceration on the pediatric patient, we apply this method using ribbon shaped knot. On stitching out, We pull one the edge of a stitching fiber easily without injury about normal tissue. Methods: We studied 54 pediatric patients who have facial lacerations for children under six years old, from May, 2006 to December, 2007 in Plastic Surgery department, emergency room. Among them 35 were male, 19 were female and age average was 3.9. Results: For following up dressing, ribbon shaped knot did not get loose. After stitching out in facial laceration on children, Major complication of infection, hematoma, dehiscence was not found. Conclusion: The advantage of this operation method using ribbon shaped knot when we Stitch out the fiber on the incorporative pediatric patients, is easy to perform and to reduce the stitching time, without sedation.

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

Experience with Operating a Trauma Team at a Local Private University Hospital (일개 지방사립대학병원에서의 중증외상팀 운영경험)

  • Kim, Yong Hwan;Yang, Young Mo;Lee, Jang Young;Lee, Won Suk;Sung, Won Young;Bark, Koung Nam
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.99-103
    • /
    • 2013
  • Purpose: This hospital has operated a trauma system of the inclusive trauma system under the sponsorship of this hospital and with financial support from the government from 2011, and it has been designated as a specialized trauma center (candidate) since November 2008. Therefore, this emergency medical center evaluated the influence of the inclusive trauma system on the course of healing and on the results for trauma patients within the region. Methods: The medical records of all patients who were registered as trauma patients from among those who visited the emergency medical center of this hospital from April 2009 to May 2012 were retrospectively reviewed. The monthly and the annual averages of important indices, such as the time in the emergency room and preventable mortalities, were calculated, and patterns of change were sought. The preventable mortality rate was calculated by using the Trauma Injury Severity Score (TRISS) for each patient. Results: The total number of patients registered from April 2009 to May 2012 was 601, and male patients accounted for a larger proportion(432 males(71.88%) vs. 169 females(28.12%)). Their average age was 46.2 years, the average Revised Trauma Score (RTS) was 5.74 points, and the average Injury Severity Score (ISS) was 26.99 points. The preventable mortality rate during the entire period, which was calculated using the TRISS, appeared lower than the preventable mortality rates reported in past studies in the Republic of Korea. Conclusion: These results for the operation of a new trauma system are limited in that they are only for a local private university hospital. However, results show greater changes and developments in and out of the hospital due to multilateral endeavors by the trauma team and the hospital. These endeavors include increased communications among the departments and development of a complementary patient registration system.