• Title/Summary/Keyword: operation evaluation

Search Result 4,101, Processing Time 0.028 seconds

Development and Application of the Slope Management Program in Urban Area (대도시 사면관리프로그램 개발 및 적용)

  • Kim, Kyeong-Su;Chae, Byung-Gon;Cho, Yong-Chan;Lee, Choon-Oh;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.15-25
    • /
    • 2007
  • In general, the life and asset casualties that occur due to landslide or slope failure in urban areas are larger than that in rural areas. In order to reduce the casualties, a slope management program is necessary to categorize slopes based on properties and to manage them systematically. The slope management system is the establishment of the data base for the geological and geotechnical factor according to slope stability, and the utilization of the data base to manage slopes. The suitable system must develop to slopes in urban area through the survey, analysis and evaluation process. Based on the above necessity, the slope management program which is applicable to slope management in an urban area has been developed at Hwangryung Mt. in Busan as a target area. The developed slope management program has various functions such as slope ID number of each slope or sub-region of a mountain, making a slope data sheet, analysis and grouping of slope stability, and establishment of a data base. The slope management program is constructed by use of GIS, and the survey, test and analysis data according to all slopes can be input and edited into the program. The program can also be utilized practically by end users due to the convenient input, edition printing, management and operation of slope data. Therefore, the slope management system has been established on the application of the developed program in Busan which is located in slope area. As the system is widely applied to other cities, the slope in urban area can be managed systematically and the slope hazards can be minimized.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients (유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가)

  • Jung, In Ho;Kim, Joon Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • Purpose : We investigated the safety of Intrabeam$^{TM}$ system, X-ray unit for Intraoperative Radiotheray (IORT) by measuring surface dose using Optically Stimulated Luminescent Dosimeter(OSLD). Materials and Methods : 30 patients were selected, who were in breast cancer patients and had an operation of breast conserving surgery (BCS). At the inner surface of tumor bed, 20 Gy were described, and 5 Gy at 1cm depth from the inner surface. Along the size of tumor bed which could be decided after resection of tumor, the size of applicator were determined. Usual treatment time were from 18 to 40 minutes. For the measurement of surface doses, OSLD were placed at superior(U1,2), inferior(D1,2), lateral(L1,2) and medial(M1,2) directions from the center of applicator. Each direction, two OSLD were placed at 0.5 cm and 1.5 cm from the center. Mean, maximum, and minimum doses were analyzed to be compared. Results : Mean values were U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, and M2 $1.51{\pm}0.58Gy$. Maximum values were 4.34 Gy at U1, and Minimum values were 0.45 Gy at M2. 13.3 % of patient (4pts out of 30) were reported that surface dose were over 4 Gy. Conclusion : The fact that skin dose of all patients were less than 5 Gy based on OSLD measurement showed the safety of Intrabeam$^{TM}$ system. In the relatively small breast volume, the tendency that surface dose was increased had been shown, which was analyzed by the data of patients who irradiated over 4Gy at skin surface. Therefore, for appropriate indication for IORT, it is suggested that breast volume as well as the size and position of tumor should be carfully considered.

  • PDF

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

Management Efficiency of Chestnut-Cultivating Households in Chungnam Province (충남지역 밤나무 재배 임가의 경영 효율성 분석)

  • Won, Hyun-Kyu;Jeon, Jun-Heon;Yoo, Byoung-Il;Lee, Seong-Youn;Lee, Jung-Min;Ji, Dong-Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.3
    • /
    • pp.390-397
    • /
    • 2013
  • The study, utilizing a data envelopment analysis (DEA) which is one of the nonparametric estimation methods, aims to evaluate the management efficiency of chestnut tree cultivators in such provinces in Chungchungnam-do as Cheong-yang, Gong-ju, Bu-yeo and so on. The analysis data of this study is based on inputs and outputs of 20 forestry households surveyed in the 2012 survey titled 'A Study on Current Level and Condition of Chestnut Cultivation and Management', which was conducted from March 2012 to October 2012. The elements of inputs are composed of management cost, harvesting cost, material cost, non-operation expenses and cultivation area, while the element of output is a gross margin only. Then the study analyzes a technical efficiency, a puretechnical efficiency and a scale efficiency using CCR and BCC model among DEA methods. Based on that, it also provides improvement methods for forestry households that turned out to be inefficient. In order to verify the result of DEA analysis, the study additionally compares a result of this efficiency study with that of chestnuts management standard diagnostic table. According to the result, the average value of technical efficiency analyzed was 0.667, proving to be inefficient in general. Given that the average value of pure-technical efficiency was 0.944 and that of scale efficiency was 0.703, it can be inferred that inefficiency exists in the field of scale, not in the field of cultivation techniques. As for forestry households with the efficiency score of 1, it is shown that there were 6 households that recorded 1 in the technical efficiency field and 13 households that recorded 1 in the pure technical efficiency. Meanwhile, there were 6 households that recorded 1 in all of the three aspects. In the comparison with the scores from chestnuts management standard diagnostic table, there were 5 households made a high score of over 80, among which are 3 households with score 1 in the technical efficiency. Also, the results of this study and the chestnuts management standard diagnostic table are proved to have the same result, both of them showing the same households that recorded the highest score and the lowest score. This means the management efficiency evaluation using DEA can be applied to the fieldwork along with the chestnuts management standard diagnostic table.

Fabrication of Label-Free Biochips Based on Localized Surface Plasmon Resonance (LSPR) and Its Application to Biosensors (국소 표면 플라즈몬 공명 (LSPR) 기반 비표지 바이오칩 제작 및 바이오센서로의 응용)

  • Kim, Do-Kyun;Park, Tae-Jung;Lee, Sang-Yup
    • KSBB Journal
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • In the past decade, we have observed rapid advances in the development of biochips in many fields including medical and environmental monitoring. Biochip experiments involve immobilizing a ligand on a solid substrate surface, and monitoring its interaction with an analyte in a sample solution. Metal nanoparticles can display extinction bands on their surfaces. These charge density oscillations are simply known as the localized surface plasmon resonance (LSPR). The high sensitivity of LSPR has been utilized to design biochips for the label-free detection of biomolecular interactions with various ligands. LSPR-based optical biochips and biosensors are easy to fabricate, and the apparatus cost for the evaluation of optical characteristics is lower than that for the conventional surface plasmon resonance apparatus. Furthermore, the operation procedure has become more convenient as it does not require labeling procedure. In this paper, we review the recent advances in LSPR research and also describe the LSPR-based optical biosensor constructed with a core-shell dielectric nanoparticle biochip for its application to label-free biomolecular detections such as antigen-antibody interaction.

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

The Change of Health Service before and after the Unification of two Health Subcenters in a Rural Area (한 농촌지역 2개면 보건지소 통합전후 보건의료사업 변화 연구)

  • Sul, Sue-Jeong;Park, Hyang;Sohn, Seok-Joon;Park, Jong;Kim, Ki-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.2
    • /
    • pp.427-440
    • /
    • 2000
  • A comparative study was made about health resources, medical care service statistics and public health service statistics by health subcenters at Jangdong and Jangpyung townships, Jangheung County, Chollanamdo before and after the unification of two health subcenter to improve their function. 1. While two general physicians, one dentist, 4 nurse aids arid one oral hygienist were working at two health subcenters with simple facility with examination room and public health office in 1997 prior to the unification, in 1999 after the unification of two health subcenters 14 staff including a specialist physician, a general physician, a dentist, a herb hygienist, a radiology technician and a physical therapist were working in the new health subcenters equipped with appropriate facilities in two storey building. 2. In 1997 before the unification the yearly total income of two health subcenters was 78,815 thousand won(about 14,000 won per capita) and the amount was 140,376 thousand won(about 25,000 won per capita) in 1999 after the unification. And the income was used for operation of health subcenters excluding personnel expense. 3. While 90.5% of visitors to the health subcenters came for general medical care, and 91.6% came for the revisit before the unification, after the unification 71.2% came for general medical care, 10.8% for dental care, 16.5% for oriental physician's care, 29.7% for the first visit and 70.3% for revisit. Most common problem cared for was musculoskeletal disorder like arthralgia. Average treatment cost per person per month was 9,363 won before the unification and 8,309 won after the unification. 4. Through the comparison of execution rate of public health services before and after the unification. the practice rate of most health service among target population including visiting service for chronic illness, maternal and child health service and immunization service increased after the unification. The practice rate of tuberculosis control service, hypertension control and diabetes management was a little decreased. In conclusion, continuous effort to satisfy all persons in two townships and evaluation are necessary to coincide with the spirit of unification of two health subcenters.

  • PDF

Development of a Small Size Hammer Mill for Farm Use (I) (농가용(農家用) 소형(小型) 사료(飼料) 분쇄기(粉碎機) 개량(改良)에 관(關)한 연구(硏究) (I))

  • Chang, D.I.;Kim, S.R.;Kim, M.S.;Lee, B.D.;Yi, K.J.
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.334-344
    • /
    • 1983
  • This study was conducted to investigate the variables affecting the performance of hammer mills by the theoretical and dimensional analysis, and evaluate the power requirements of hammer mills for farm use in Korea. From the theoretical analysis, 16 variables affecting the performance of hammer mills were defined. In order to develop the mathematical relationships among the variables, the dimensional analysis was made for power requirements and $12{\pi}$ parameters were obtained. For the evaluation of the power requirements of hammer mills, approximate rates of grinding for 1HP, 3HP, 5HP, 6HP, 8HP, and 10HP were analyzed. Then, the fineness of grinding recommendation and average feeding rate of grain for livestock which is native cattle, dairy cattle, beef cattle, swine, broilers, and layers, were estimated. Finally number of livestock feeding shelled corn and barley were estimated from the above for one hour's hammer mill operation having the various power requirements. From this study it is known that 5HP is considered as an enough power for feed grinding of any kinds of livestock of Korean farm, as far as the grinding capacity is concerned.

  • PDF

A Study on the Performance of Cloud-based VDI Adoption: Comparing between IS administrators and business users (클라우드 기반 VDI 도입 성과에 관한 연구 - 시스템 관리자와 일반 사용자의 비교를 중심으로 -)

  • Kim, Il-Han;Kwon, Sun-Dong
    • Management & Information Systems Review
    • /
    • v.37 no.2
    • /
    • pp.149-167
    • /
    • 2018
  • The purpose of this study is to analyze the performance of Virtual Desktop Infrastructure(VDI) adoption. VDI performance was measured by IS manager (system quality, security, and managerial operation) and business user (usability, access, and user satisfaction). The survey questionnaires were developed for measuring VDI performance. 84 data samples were collected from the companies that had adopted cloud-based VDI. This research model was verified by Smart-PLS and SPSS. The research findings were as follows: First, the companies using VDI experienced actual performance, but they did not attain their expectation. Second, as results of comparing between IS managers and business users, IS administrators had considerably higher performance than business users, which indicates that there were big differences in performance perception among users. Compared with prior research such as technical trend, system construction, and performance improvement, this study has the following implications. First, by comparing the expected performance with the actual performance of the companies that have implemented and operating VDI, it was suggested how a company that wants to adopt VDI can manage the expectation level of VDI and achieve higher actual performance. Second, because the perception of VDI performance differs between business users and system managers, it is meaningful that a fair evaluation of VDI performance requires a balanced consideration of business users and system managers.