• 제목/요약/키워드: operation evaluation

검색결과 4,077건 처리시간 0.035초

동적인 B-spline 곡선과 곡면의 효율적인 평가방법 (Fast Evaluation of a dynamic B-spline Curve and Surface)

  • 류중현;김덕수
    • 한국산업경영시스템학회:학술대회논문집
    • /
    • 한국산업경영시스템학회 2002년도 춘계학술대회
    • /
    • pp.461-466
    • /
    • 2002
  • In many applications of computer aided geometric design and computer graphics, B-spline is one of the most popular representation for curves and surfaces, and the evaluation of B-spline curves and surfaces is the most frequently used operation. For the evaluation and others, the power form representation of the curves and surfaces is preferred because it is possible to speed-up the operation using Horner's rule. In this paper, we present a new algorithm for the above-mentioned conversion focusing on a dynamic case. Experiment shows that the proposed algorithm significantly outperforms the conventional approach when one or more control points of a B-spline curve and surface are dynamically moving.

  • PDF

5축 복합가공기의 에너지 저감을 위한 기술 및 적용 방안 (Design Approaches and Strategies for Energy Saving of 5-Axis Multi-Functional Machine Tools)

  • 김태성;김경동;이찬홍;남성호
    • 한국정밀공학회지
    • /
    • 제30권5호
    • /
    • pp.467-473
    • /
    • 2013
  • Diverse approaches for reducing the total energy consumption of machine tools have been introduced and developed, to cope with rapid increase of total energy costs in world-wide manufacturing industries. To realize the improvement of the energy efficiency, systematic and integrated strategies must be considered, including energy-saving design, optimized control operation and concrete evaluation of the energy efficiency. This paper proposes key enabling technologies required to improve the energy efficiency of 5-axis multi-functional machining tools, considering both of system design and operation in the real production environments. Related standardized procedures of the energy efficiency evaluation is also represented.

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

전력계통 운용상태의 신속한 판단을 위한 정보수집 및 추론기법에 관한 연구 (A Study on Information Collection and Inference Technique for Fast Evaluation of Power System Operation State)

  • 박찬엄;홍창호;이승철;문운철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.34-35
    • /
    • 2006
  • This paper presents an information collection and a novel inference technique for evaluation of power system operation state. In most developing countries, power demands are steadily increasing and consequently power systems are becoming larger and more complicated. In addition, power system deregulations further complicate the power system operational tasks, which are resulted in prevailing wide area blackouts worldwide. In this paper, we proposed an effective information collection and operating state evaluation methods using a knowledge-based system. The RTS-79 24 bus system is used as a test system. The power system model is composed with JESS templates and included in the knowledge-base as a part of fixed facts. Dynamic informations are collected from various analysis results and actual operational data. Inferences are performed with rules expressed with terms in different abstraction levels. Future research will be concentrated on intelligent contingency selections for preventing wide area blackouts.

  • PDF

자동순항제어기에 의한 안전도 향상 효과 분석 (Evaluation of the Safety impact by Adaptive Cruise Control System)

  • 이태영;이경수;이찬규;이재완
    • 자동차안전학회지
    • /
    • 제4권1호
    • /
    • pp.5-11
    • /
    • 2012
  • This paper discusses the evaluation of the safety impact of the Adaptive Cruise Control (ACC) system in Korea. To evaluate the safety impact, this paper suggests an analysis method by using the test scenario and field operational test data. The test scenario is composed to represent the main component factor of the ACC system and ACC related accident situation such as rear-end collision, lane-change, and road-curvature, etc. Also, from the field operation test data, the system's potential to increase the safety can be measured ideally. Besides, field operational testdata was used to revise the expected safety impact value as Korean road conditions. By using the proposed evaluation method, enhanced safety impact of the ACC system can be estimated scientifically.

한국형 고속열차를 활용한 기존선 전철화 구간에서 고속열차 운행의 적합성 평가 (Test and evaluation on the suitability of operating high speed train in electrified conventional line through test run of HSR-350x)

  • 목진용;김영국;김기환;조민영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.229-235
    • /
    • 2007
  • The KTX, which have opened the revenue service in April 2004, is operating in Kyoung-Bu high-speed line and electrified conventional Ho-Nam line, and the more the electrification are enlarged, the more the requirement of operating of high speed train would be increased. In this paper, the result of test run and evaluation on the suitability of operating high speed train in electrified conventional line between Dae-jeon and East Dae-gu was reviewed. Evaluation and analysis was executed in specific categories, such as operation & running performance of the train considering vibration characteristics based on UIC 518, ride comfort and current collection, and response sensitivity of ATS device for signalling from track facility. The result of this running test was evaluated and considered as a good practice for revenue operation of high speed train in electrified conventional line between Dae-jeon and Dae-gu.

  • PDF

확정적 경우의 유연생산시스템 성능평가방법 (FMS Performance Evaluation Method of Deterministic Model)

  • 황규완;배홍석
    • 산업경영시스템학회지
    • /
    • 제19권37호
    • /
    • pp.71-85
    • /
    • 1996
  • There are studied on the evaluation of flexibility and design/operation of FMS. However. a new method that can assess the performance of FMS is propose in this study. To evalute the performance of an FMS the ordinary for total cost is not applied. Instead, a specially developed cost function is used to measure the performanced of proposed systems. The procedure is developed for deterministic variables cases. An FMS can produce various products systematically under computer control the evaluation of an FMS operation is not a simple task. The proposed procedure is done through computer simulation due to the complicated nature of the problem. A simulation model is developed using SIMAN and FORTRAN for practical application.

  • PDF

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong;Kwon Boo-Kil
    • Journal of Mechanical Science and Technology
    • /
    • 제20권3호
    • /
    • pp.329-334
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performances of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after about six-year-use of the regulators.

4kW급 상용차량용 전력전자 냉방장치의 열 환경 성능평가 (Thermal environmental performance evaluation of 4kW power electronic cooling system for commercial vehicle)

  • 한근우;김성곤;이충훈;최명현;정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.290-291
    • /
    • 2017
  • This study deals with an evaluation method for testing the robustness of the 4 kW commercial power electronic cooling system to the thermal environment. The power electronic cooling system consists of a cascaded push-pull DC / DC converter, a three-phase DC / AC inverter, and an electric compressor. The system manufactured by the thermal environment evaluation test (heat distribution test, thermal impact test, high temperature operation test, temperature cycle test, low temperature operation test) for the commercial electric power cooling system for commercial vehicle proves that it is robust against thermal environment.

  • PDF

운행 프로파일 기반 도시철도차량용 반도체 변압기의 전력 반도체 소자 수명 평가 (Operation-Profile Based Lifetime Evaluation of Power Semiconductor Devices in Solid-State Transformer for Urban Railway Vehicles)

  • 최의민;박진혁;김명룡;이준석
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.496-502
    • /
    • 2020
  • The reliability of a solid-state transformer (SST) is one of the important aspects to consider when replacing a conventional low-frequency passive transformer with SST for urban railway vehicles. Lifetime evaluation of SST in the design phase is therefore essential in guaranteeing a certain SST reliability. In this study, a lifetime evaluation of power semiconductor devices in SST is performed with respect to temperature stress. For a case study, a 3 MW SST with three kinds of power modules (one IGBT module and two SiC-MOSFET modules) is used for the lifetime estimation under the operation profile of urban railway vehicles.