• Title/Summary/Keyword: operation evaluation

Search Result 4,068, Processing Time 0.032 seconds

An Experimental Study on the Estimation of Oil Discharge Rate from Inverter Rotary Compressor (인버터 로터리 압축기 오일 토출량 산정의 실험적 고찰)

  • Sin, Hyun-Seok;Byun, Soon-Seok;Tae, Sang-Jin;Moon, Je-Myung;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.28-32
    • /
    • 2011
  • The inverter rotary compressor discharges refrigerant and compressor oil in air-conditioning systems. The compressor oil which discharged form compressor decreases the efficiency of heat exchanger and affects the compressor operation. Recently, several studies are in progress for reducing the compressor oil. Before the reduction of compressor oil discharge rate, the quantitative measurement and evaluation method are required. In order to cope with this requirement we have developed the measurement technic of oil discharge rate. The reliability assessment was carried out approximately 0.1% of the errors with compressor performance indicators. The acceptable errors were to ensure the reliability of measurement technic. In the experiment results at several conditions, The oil discharge rate of heating operation has been confirmed average 3.7 times more than cooling operation. In this study the evaluation method and the experimental results of oil discharge rate in air-conditioning systems are presented with various operating conditions.

Development of Aging Diagnosis Algorithm for Photovoltaic Modules by Considering Electric Characteristics and Environment Factors (전기적특성과 환경인자를 고려한 태양광모듈의 열화진단 알고리즘 개발)

  • Lee, Kye-Ho;Choi, Sung-Sik;Kim, Byung-Ki;Jung, Jong-Yun;Kim, Chan-Hyeok;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1411-1417
    • /
    • 2015
  • The installation of PV system to the power distribution system is being increased as one of solutions for environmental pollution and energy crisis. However, the efficiency of PV system is getting decreased because of the aging phenomenon and several operation obstacles. Therefore, The technology development of aging diagnosis of PV modules are required in order to improve operation performance of PV modules. This paper proposes evaluation algorithm for aging state in PV modules by using the electrical characteristics of PV modules and environmental factors. And also, this paper presents a operation evaluation system of PV modules based on the proposed aging diagnosis algorithm of PV modules. From the simulation results of proposed evaluation system, it is confirmed that the proposed algorithm is a useful tool for aging diagnosis of PV systems.

Local-Generator-Based Virtual Power Plant Operation Algorithm Considering Operation Time

  • Park, Sung-Won;Park, Yong-Gi;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2127-2137
    • /
    • 2017
  • A virtual power plant (VPP) is a system that virtually integrates power resources based on the VPP participating customer (VPC) unit and operates as a power plant. When VPP operators manage resources to maximize their benefits, load reduction instructions may focus on more responsive VPCs, or those producing high profitability, by using VPC resources with high operation efficiency. VPCs may thus encounter imbalance problems during operation. This imbalance in operation time would bring more participation for some VPCs, causing potential degradation of their resources. Such an operation strategy would be not preferable for VPP operators in managing the relationship with VPCs. This issue impedes both continual VPC participation and economical and reliable VPP operation in the long term. An operation algorithm is therefore proposed that considers the operation time of VPC generators for mandatory reduction of power resource consumption. The algorithm is based on constraints of daily and annual operation times when VPP operators of local generators perform capacity-market power transactions. The algorithm maximizes the operator benefit through VPP operations. The algorithm implements a penalty parameter for imbalances in operation times spent by VPC generators in fulfilling their obligations. An evaluation was conducted on VPP operational effects by applying the algorithm to the Korean power market.

A study on advanced EMU's maintenance program on test operation in Dabul line (차세대 전동차 대불선 시운전 시 유지보수방안 연구)

  • Kim, Young-Kyu;Park, Se-Young;Song, Jeong-Hun;An, Cheon-Heon;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2215-2222
    • /
    • 2010
  • Advanced EMU have been enhanced in terms of safe transport and maintainability. It is a new urban railway technology that enables an operation institution to cut repair and maintenance costs and customers to use convenient service at lower costs based on IT technology. If a development vehicle of Advanced EMU is completed, it will be used to test the entire advanced EMU system through sufficient performance check and reliability check prior to operation in commercial line. It will also verify efficiency, safety, punctuality and energy efficiency of transport. Accordingly, it is necessary to figure how to repair and maintain vehicles to enhance safety of Advanced EMU system in cooperation with operation during the period of comprehensive evaluation on the operation of a development vehicle in a test line. In this paper, we investigated the maintenance program of Advanced EMU on test operation in Dabul line. The test condition and operation environment of Advanced EMU in Daebul line was analyzed.

  • PDF

A Study on the Services Performance Evaluation of Intelligent Network Facilities (지능망 설비에서의 서비스 성능평가에 관한 연구)

  • 전희종;오중민;김춘수;김병진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.50-57
    • /
    • 1995
  • In this paper the model was analyzed on performance evaluation for IN facility and we carried out evaluation on it's service performance using this model as an example. We used simulation method and operation analysis method as evaluation technology. As the evaluation results, the case of simulation method was nearly consistent with the case of the operation analysis method and the user-network interaction time had more effect on service performance than delay time of IN facility. We expects that the performance models proposed in this paper is useful when operating, managing and designing IN services in considering service performance.

  • PDF

Performance Evaluation of Set-top Box Energy Saving using Poisson Process Modeling (포아송 프로세스 모델링을 통한 셋톱박스 에너지 절감 성능 분석)

  • Kim, Yong-Ho;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2011
  • This paper considers a performance analysis of set-top box (STB) power saving schemes. STB converts the signal into content which is then displayed on the television (TV) screen, and there are typically two operation modes: on mode and stand-by mode. The total energy consumption (TEC), a typical measure of power consumption of STB, is defined by the sum of power consumption in each mode. Recently there are some works of STB power saving schemes that transit STB operation modes efficiently, and the mode transition time point of those schemes can be different. Thus it is required to develop a performance evaluation method that reflects mode transition time points of each scheme to get TEC correctly. This paper proposes a performance evaluation method for STB power consumption using Poisson process to consider the mode transition time point. By modeling STB mode transitions as events of Poisson process, the average time duration of STB mode is computed and accordingly the effect of power saving is evaluated. The performance evaluation result shows that the proposed method achieves 1 to 19% improvement in power consumption compared with a conventional performance evaluation method.

  • PDF

Performance Evaluation of Solar Water Heating System Using Proof Test (태양열 온수기 실증연구를 통한 성능 평가)

  • Kim, Jae-Yeol;Kwac, Lee-Ku;Yang, Dong-Jo;Choi, Choul-Jun;Kim, Hong-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

The Quantification of Considerations related with Decision-making in Ground Operation : Focusing on Evaluating Avenues of Approach in IPB (지상작전과 연관된 의사결정 고려요소의 정량화 방안 : 전장정보분석의 접근로 평가요소를 중심으로)

  • Han, Seung Jo;Lee, Seungmin
    • Convergence Security Journal
    • /
    • v.19 no.2
    • /
    • pp.129-136
    • /
    • 2019
  • The main tasks of commander and staffs in ground operations are a continuation performing the process of making decisions in various situations. Since the current decision-making process is largely dependent on qualitative methods, it is difficult to integrate with the decision-making tools associated with the 4th Industrial Revolution. The purpose of this study is to suggest the process of deriving the relative importance of the evaluation factors using the AHP with focusing on assessing the avenues of approach in IPB related to the ground operation plan. The most important aspect of IPB is the evaluation of the avenues of approach. Evaluation factors include target accessibility, observation and seasons, concealment and cover-up, ease of maneuverability, and ease of transition to adjacent access roads. The existing methods are the comparison method with evaluation factors and the analysis with the advantages and disadvantages. However, it has been criticized that they regard evaluation factors as equal importance. The results show that target accessibility has the highest score related with priority when considering the criteria.

Economical Evaluation Based on Method of Coagulation with GAC Adsorber Operation (활성탄 흡착지의 운영시 응집 방법에 따른 경제성 평가)

  • Hong, Seongho;Sung, Dae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.473-479
    • /
    • 2005
  • Applying enhanced coagulation is not uncommon not only to improve water quality but also to obtain economical advantages in water treatment. In this study, the economical evaluation was investigated with considering dosage of coagulant, produced sludges and usage of activated carbon with two different water sources. To simulate the granular activated carbon(GAC) adsorber mini-column test was adapted. Even if there were some variation according to the source waters, the life time of GAC was extended 60 to 110days with adding 2.5 to 3 times of coagulant in enhanced coagulation. With assumption of changing GAC adsorber at 50% of breakthrough the total treatment cost can be reduced to range from 25% to 44% with adapting the enhanced coagulation. The obtained value can not be generalized because the value can be varied by water quality and cost of the GAC or coagulant. However, the evaluation can be basis starting point to find optimum operation methods for the drinking water treatment which has plan to adapt GAC adsorber.

A Study on Satisfaction of New Employee Engineering Introduction Training Program Applying CIPP Evaluation Model Focusing on D Corporation (CIPP 평가 모형을 적용한 대기업 사원 공학입문 교육 만족도에 관한 연구)

  • Jeon, Ju-Hyun;Lee, Jae-Eung
    • Journal of Engineering Education Research
    • /
    • v.16 no.3
    • /
    • pp.79-86
    • /
    • 2013
  • The purpose of this study was to analyze the factors related to the satisfaction of the introductory engineering education program for the employees, who majored liberal arts or commerce, among the educational programs for industrial workers which are performed as an effort to spread the performance of the Innovation Center for Engineering Education, and reinforce the competitiveness through effective program operation. This study was performed on the basis of CIPP evaluation model (context, input, process, product). A factorial analysis and a regression analysis were conducted based on a survey made on 87 persons who completed the introductory engineering education program among the employees of D group who majored liberal arts or commerce. It is expected that this study will contribute toward suggesting the implications for designing and operating the educational programs for industrial workers in order to find out the important factors of satisfaction and to conduct the education operation with professionalism.