• 제목/요약/키워드: operating temperature

검색결과 3,662건 처리시간 0.029초

수소저장합금을 이용하는 수소공급시스템의 운전 방법 최적화 (Operating Strategy Optimization of Metal Hydride based Hydrogen Supply System)

  • 김병준;성해정;이영덕;이상민;조주형;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.625-633
    • /
    • 2011
  • Characteristics of a commercial metal hydride (MH) hydrogen supply system have been investigated and an operating strategy was developed based on the experimental data. As a prior step, charging/discharging capacity, thermal properties such as heat capacity, heat of reaction of MH system were experimentally measured. And then P-C-T data for various operating conditions were collected and a correlation between P, C and T predicting the behavior of MH was derived. Based on the basic experimental data, an operating strategy of MH system was developed, in which the hot water temperature supplied into the water jacket of MH was controlled depending on the pressure of MH, thereby the pressure of MH could be maintained at a suitable range. By adjusting the temperature of hot water from $40^{\circ}C$ to $60^{\circ}C$, the maximum discharging capacity of hydrogen could be increased by 4.7%, and consequently more stable hydrogen supply and longer operation time of fuel cell system could be achieved.

내부 열교환기 부착 R744-R404A용 캐스케이드 냉동시스템의 성능 분석 (Performance analysis of a R744 and R404A cascade refrigeration system with internal heat exchanger)

  • 오후규;손창효
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.38-43
    • /
    • 2012
  • This paper describes an analysis on performance of R744-R404A cascade refrigeration system with internal heat exchanger to optimize the design for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporating and condensing temperature in the R744 low- and R404A high-temperature cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : COP of cascade refrigeration system increases with the increasing of compression efficiency, but decreases with the increasing temperature difference of cascade heat exchanger. Also, the COP increases with the increasing of internal heat exchanger efficiency in high-temperature cycle, but decreases with that in low-temperature cycle. Therefore, internal heat exchanger efficiency, compressor efficiency and temperature difference of cascade heat exchanger on R744-R404A cascade refrigeration system have an effect on the COP of this system.

R744-R717 캐스케이드 냉동시스템에서 운전조건 변화에 따른 성능 해석 (Performance Simulation of a R744-R717 Cascade Refrigeration System According to Operating Conditions)

  • 유지호;조홍현
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.497-505
    • /
    • 2015
  • The evaporating temperature range required for the low temperature freezing system is from $-50^{\circ}C$ to $-30^{\circ}C$. Since it is difficult to keep the required capacity in a cabinet, it is advantageous to design the system using a cascade refrigeration system. Use of carbon dioxide and ammonia would be advantageous since ammonia is an environment-friendly working fluid and has a high capacity for performance improvement. To investigate the performance characteristics of the R744-R717 cascade refrigeration system, a theoretical model was developed and performance was analyzed according to cascade heat exchanger operating temperature. The optimal cascade R744 condensing temperature was $-5^{\circ}C$, and maximum COP was 1.13 when the temperature difference of the cascade heat exchanger was $5^{\circ}C$. In addition, the total system COP increased by 1.17 when the cascade temperature gap was $3^{\circ}C$ at the middle temperature of $-7.5^{\circ}C$.

PCB 건조공정의 흄과 미스트에 대한 열안정성 분석 (The Thermal Stability Analysis of Fumes and Mists During the Drying Process of a PCB)

  • 추창엽;이정석;백종배
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.32-40
    • /
    • 2019
  • During the manufacturing process of a printed circuit board(PCB), fumes and mists are generated as the ink dries on the PCB surface. The generated fumes and mists are deposited in the dryer wall and the exhaust duct. Deposited fumes and mists may present a fire hazard if the dryer temperature control system fails. In this study, the thermal stability of the fumes and mists deposited in the dryer and ducts has been analyzed by experimental methods such as thermo gravimetric analysis (TGA), differential scanning calorimetry (DSC), auto ignition temperature (AIT), and multiple mode calorimetry(MMC). According to the experimental analyses, experimental samples are likely to generate gas at the temperature ($180{\sim}240^{\circ}C$) that deviates from the normal operating temperature ($150{\sim}156^{\circ}C$). It has been shown that the thermal stability is degraded when the temperature is deviated from the normal operating temperature. In the end, engineering and management safety measures of accidental prevention have been suggested.

주위온도조건이 스터링 극저온냉동기의 성능에 미치는 영향 (Effects of the environmental temperature on the performance of the Stirling cryocooler)

  • 홍용주;김효봉;박성제
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.65-68
    • /
    • 2009
  • The Stirling cryocoolers have been widely used for the cooling of the infrared detector(InSb, HgCdTe, and etc,) and HTS(High Temperature Superconductor) to the cryogenic temperature. The monobloc Stirling cryocoolers with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. The typical performance factors of the Stirling cryocooler are the cool-down time, cooling capacity at the desired temperature (80 K), the electric input power and COP. The above performance factors depend on the operating conditions such as the charging pressure of the helium gas, the thermal environment and etc.. In this study, the effects of the thermal environment (temperature of 241, 293, and 333 K) on the performance of the cryocooler were investigated by experiments. The results show the effects of the temperature of the thermal environment on the cooling capacity and input power.

고로내 열유동 현상의 수치해석 사례(I) (Numerical simulation of thermo-fluid flow in the blast furnace)

  • 진홍종;최상민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2038-2043
    • /
    • 2007
  • Analysis of the internal state of the blast furnace is needed to predict and control the operating condition. Especially, it is important to develop modeling of blast furnace for predicting cohesive zone because shape of cohesive zone influences on overall operating condition of blast furnace such as gas flow, temperature distribution and chemical reactions. Because many previous blast furnace models assumed cohesive zone to be fixed, they can't evaluate change of cohesive zone shape by operation condition such as PCR, blast condition and production rate. In this study, an axi-symmetric 2-dimensional steady state model is proposed to simulate blast furnace process using the general purpose-simulation code. And Porous media is assumed for the gas flow and the potential flow for the solid flow. Velocity, pressure and temperature distribution for gas and solid are displayed as the simulation results. The cohesive zones are figured in 3 different operating conditions.

  • PDF

캐소드극 입구 가습 조건이 고분자 전해질 연료전지의 성능에 미치는 영향 (Effect of Inlet Humidity Condition at Cathode Side on Performance of a Polymer Exchange Membrane Fuel Cell)

  • 문철언;이서희;고동수;양장식;최경민;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3423-3428
    • /
    • 2007
  • This paper shows that inlet humidity condition at cathode side is one of dominant parameters affecting the performance of PEMFC. To investigate effects of inlet humidity condition, the performance measurements were conducted for a single PEMFC with two operating variables : cathode relative humidity and dry condition in anode dry. The fuel cell employed for the experiments is a unit PEMFC with a 25$Cm^2$, Nafion$^(R)$112 membrane. As a result of this study, the cell performance is getting higher by increasing inlet humidity condition at cathode side. The cell performance is different from each operating temperature an it has maximum30% higher than dry condition at 60$^{\circ}C$ operating temperature with 80% relative humidity.

  • PDF

Experimental Analyses of Cell Voltages for a Two-cell PEM Stack Under Various Operating Conditions

  • Park, Sang-Kyun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.881-890
    • /
    • 2011
  • Analyses of performance and behavior of the individual PEM fuel cells (PEMFC) under different operating conditions are of importance optimally to design and efficiently to operate the stack. The paper focuses on experimental analyses of a two-cell stack under different operating conditions, which performance and behavior are measured by the voltage of a cell as well as the stack. Experimental parameters include stoichiometric ratio, temperature of the air supplied under different working stack temperatures and loads. Results showed that the cell voltages are dominantly influenced by the temperature of the air supplied among others. In addition, an inherent difference between the first and the second cell voltage exists because of the tolerances of the cell components and the resulting different over-potentials at different equilibrium states. Furthermore, it is shown that the proton conductivity in the membranes conditioned by the humidity in the cathode channel highly affects the voltage differences of the two cells.

Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구 (A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy)

  • 황용하
    • 융복합기술연구소 논문집
    • /
    • 제1권2호
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF

수소생산을 위한 자열개질기 작동조건의 수치해석 연구 (Numerical study on operating parameters of autothermal reformer for hydrogen production)

  • 박준근;이신구;임성광;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.507-510
    • /
    • 2008
  • Characteristics of an autothermal reformer at various operating parameters have been studied in this paper. Numerical method has been used, and simulation model has been developed for the analysis. Full Combustion reaction, Steam Reforming(SR) reaction, Water-Gas Shift(WGS) reaction, and Direct Steam Reforming(DSR) reaction are assumed as dominant chemical reactions in the autothermal reformer. Simulation results are compared with experimental results for code validation. Operating parameters of the autothermal reformer are inlet temperature, Oxygen to Carbon Ratio(OCR), Steam to Carbon Ratio(SCR), and Gas Hourly Space Veolcity(GHSV). SR reaction rate decreases with low inlet temperature. If OCR is increased, $H_2$ yield is increased but optimal point is suggested. WGS reaction is activated with high SCR. When GHSV is increased, reforming efficiency is increased but pressure drop may decrease the system efficiency.

  • PDF