• Title/Summary/Keyword: operating characteristic

Search Result 1,766, Processing Time 0.031 seconds

A Study on the Characteristic of the Thermal Environment in the Heating System at a Living Room (난방방식에 따른 거실의 열환경 특성에 관한 연구)

  • 이무진;이승수;진영언
    • Journal of the Korean housing association
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2001
  • The purpose of this study is to investigate the characteristic of the thermal environment at a living room by the heating system(floor radiation heating, forced convection heating, combined heating, radiation convection heating), and to compares the change of the thermal environment after operating the heating with after the operation stopped based on the floor radiation heating. This study proposes the basic data for the design and the development of the thermal storage structure heating system which not only utilizes fully the characteristic of the comfortable thermal environment but also reduces the preheating period and be able to use the off-peak electricity.

  • PDF

A Study on the Flow Characteristic of Non-Thermal Plasma Reactor for Demonstration (실증실험용 저온 플라즈마 반응기의 유동특성에 관한 연구)

  • Kim, Y.S.;Choi, S.H.;Kim, J.I.;Kim, T.H.;Yoo, J.S.;Paek, M.S.;Jang, G.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.508-513
    • /
    • 2000
  • HANJUNG has developed demonstration plant treating combustion flue gas such as dioxide($SO_2$) and nitrogen oxides(NOx). Before operating this system, we tested the inner airflow characteristic of demonstration plant in the front of plasma reactor field 1 and field 2. The experimental results of $25,000Nm^3/hr$ airflow are compared with the computational results using FLUENT code. It is found that the velocity distribution trends are matched the experimental results with the calculation results. To improve the eccentric airflow in the inlet hood, it is necessary to install the vertical guide vane as well as the horizontal guide vane.

  • PDF

Hot- Fire Injector Test for Determination of Combustion Stability Boundaries Using Model Chamber

  • Sohn Chae Hoon;Seol Woo-Seok;Shibanov Alexander A.;Pikalov Valery P.
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1821-1832
    • /
    • 2005
  • This study realizes the conceptual method to predict combustion instability in actual full-scale combustion chamber of rocket engines by experimental tests with model (sub-scale) chamber. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions, and hot-fire test procedures were followed to obtain stability boundaries. From the experimental tests, two instability regions are presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio, which are customary for combustor designers. It is found that instability characteristics in the chamber with the adopted jet injectors can be explained by the correlation between the characteristic burning or mixing time and the characteristic acoustic time: In each instability region, dynamic behaviors of flames are investigated to verify the hydrodynamically-derived characteristic lengths of the jet injectors. Large-amplitude pressure oscillation observed in upper instability region is found to be generated by lifted-off flames.

A study on the Stick-slip Characteristic of Machine Tool Feeding System. (공작기계 이송계의 Stick-Slip 특성에 관한 연구)

  • Park, Jong-Gwon;Lee, Hu-Sang
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.29-35
    • /
    • 1988
  • When low sliding velocities in the boundary lubrication range are operating, irregular movements frequently occur which are a result of the stick-slip phenomenon. Such slide motions are undesirable in precision machine tools, particularly with feed back systems used in numerical and adaptive control machine tools. Accordingly, this paper reports analytical and experimental studies in the stick-slip characteristic of machine tool feeding system. The main conclusions of this study are as follows; The tendency towards stick-slip effects may be reduced by; 1). Reducing the drop in friction coefficient in the Stribeck curve(on the rising part of the friction characteristic at higher sliding speeds, the system is stable all the time) 2). Reducing the transition velocity by the use of a higher viscosity lubricating oil. 3). Increasing the stiffness(Damping)and reducing normal load(Sliding mass) Therefore, the Critical velocity is decided from the above conclusions and in designing of machine tool, feed rates(sliding velocity)must be design the more than critical velocity.

  • PDF

Operating Condition Diagnosis of the Lubricated Machine Moving Surface by Image Analysis (화상해석에 의한 기계윤할 운동면의 작동상태 진단)

  • 박흥식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.79-87
    • /
    • 1999
  • The most part of the faculty drop a trouble and damage of machine equipment even if whatever cause they break out take place at local and trifling place and the factor dominating their trouble is due to wear debris occurred in the lubricated machine moving surface. This study has been car-ried out to identify morphology of wear debris on the lubricated machine moving system by means of computer image analysis. Namely the wear debris contained in lubricating oil extracted from movable machine equipment will be filtered through membrane filter(void diameter 0.45${\mu}m$) and will be analyzed with its data information such as 50% volume diameter aspect roundness and reflectivity. Morphological characteristic of wear debris is easily distinguished by four shape parameters it is necessary to divide small class of every 100 wear debris in total wear particles in order to distinguish morphological characteristic of wear debris more easily by computer image analysis. We are sure that operation condition diagnosis of the lubricated machine moving surfaces is possible by computer image analysis.

  • PDF

A Characteristic Analysis of Resonant Voltage Resultant Type DC/DC Converter (공진 전압 합성형 DC/DC 컨버터의 특성해석)

  • Hwang, Gye-Ho;Kim, Jong-Hae;Nam, Seung-Sik;Kim, Dong-Hui;Jeong, Do-Yeong;O, Seung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.1
    • /
    • pp.40-47
    • /
    • 2000
  • This paper presents a circuit of resonant voltage resultant type DC/DC converter consists of two unit half-bridge high frequency resonant inverters, and describes operating modes, principle and analysis of the proposed circuit. Also, the analysis of the proposed circuit has generally described by using normalized parameters. Based on the characteristic values, a method of the circuit design is proposed. According to phase shift, the output voltage of the proposed circuit can be controlled. In addition, the justification of theoretical analysis was certified by comparing to the experimental waveforms. In the future, this proposed converter show that it can be practically used as the system of fixed DC voltage source etc.

  • PDF

Modeling Electrical Characteristics for Multi-Finger MOSFETs Based on Drain Voltage Variation

  • Kang, Min-Gu;Yun, Il-Gu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.245-248
    • /
    • 2011
  • The scaling down of metal oxide semiconductor field-effect transistors (MOSFETs) for the last several years has contributed to the reduction of the scaling variables and device parameters as well as the operating voltage of the MOSFET. At the same time, the variation in the electrical characteristics of MOSFETs is one of the major issues that need to be solved. Especially because the issue with variation is magnified as the drive voltage is decreased. Therefore, this paper will focus on the variations between electrical characteristics and drain voltage. In order to do this, the test patterned multi-finger MOSFETs using 90-nm process is used to investigate the characteristic variations, such as the threshold voltage, DIBL, subthreshold swing, transconductance and mobility via parasitic resistance extraction method. These characteristics can be analyzed by varying the gate width and length, and the number of fingers. Through this modeling scheme, the characteristic variations of multi-finger MOSFETs can be analyzed.

Operation and Generation Characteristic of 100MW-Class Wound Rotor Synchronous Generator According to Number of Slots (슬롯 수에 따른 100MW급 권선형 동기발전기 발전특성 및 운전특성 비교)

  • Kim, Chang-Woo;Park, Yo-Han;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.4
    • /
    • pp.523-531
    • /
    • 2019
  • This paper deals with a wound-field synchronous machines(WFSM), with an electromagnet on its salient rotor, as an alternative to a permanent magnet in the rotor. We then examine the power performance characteristics, loss characteristics, V-curves and large short-circuit ratios for a large-scale synchronous generator, considering the leading and lagging operations, based on the finite-element method. We predict the performance of a 100MVA-class generator based on the operating range for a constant short-circuit ratio. At the last, We compared with the electromagnetic characteristics of three model according to number of slots.

A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent (노후화된 누전차단기의 과전류 동작 특성에 관한 연구)

  • Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

A Comparative Study on the Predictive Validity among Pressure Ulcer Risk Assessment Scales (욕창발생위험사정도구의 타당도 비교)

  • 이영희;정인숙;전성숙
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.2
    • /
    • pp.162-169
    • /
    • 2003
  • Purpose: This study was to compare the predictive validity of Norton Scale(1962), Cubbin & Jackson Scale(1991), and Song & Choi Scale(1991). Method: Data were collected three times per week from 48~72hours after admission based on the four pressure sore risk assessment scales and a skin assessment tool for pressure sore on 112 intensive care unit(ICU) patients in a educational hospital Ulsan during Dec, 11, 2000 to Feb, 10, 2001. Four indices of validity and area under the curve(AUC) of receiver operating characteristic(ROC) were calculated. Result: Based on the cut off point presented by the developer, sensitivity, specificity, positive predictive value, negative predictive value were as follows : Norton Scale : 97%, 18%, 35%, 93% respectively; Cubbin & Jackson Scale : 89%, 61%, 51%, 92%, respectively; and Song & Choi Scale : 100%, 18%, 36%, 100% respectively. Area under the curves(AUC) of receiver operating characteristic(ROC) were Norton Scale .737, Cubbin & Jackson Scale .826, Song & Choi Scale .683. Conclusion: The Cubbin & Jackson Scale was found to be the most valid pressure sore risk assessment tool. Further studies on patients with chronic conditions may be helpful to validate this finding.