Development of Automatic Module Changer for Farmbot (팜봇과 연동하는 작업기 자동체결 장치 개발)

  • Kwon, Junhyuk;Lee, Myungho;Cho, Hyungho;Hong, Hyunggil;Cho, Yongjun;Yun, Haeyong;Oh, Jangseok;Park, Huichang;Gang, Minsu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.30-35
    • /
    • 2021
  • In this study, we developed an automatic module changer for agricultural implements for using in unmanned agricultural robots. An automatic module changer is attached by lowering from the top to bottom of the implements and fixing the four fastener bars attached to the implements in combination. The lift function was implemented using seesaw-type structures to keep the engagement point constant when the automatic module changer climbs and descends, and the switching function of the automatic module changer was implemented using the link device in the cam structure. We developed an algorithm to check the presence of attachment and opening/closing of the workpiece using limit switches and verified the performance through combination assessment and weight lift test to assess whether the combination was within the error range.

Development of Degassing Valves for Food Packaging using Ring Type Rubber Disk (링타입 고무막을 이용한 식품 포장용 가스배출 밸브(Degassing Valve) 개발)

  • Yu, Ha Kyoung;Lee, Kyungo Ho;Oh, Jae Young
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.2
    • /
    • pp.35-39
    • /
    • 2014
  • One-way degassing valves are designed to allow pressure to be released from an air-tight package while preventing air from getting back into the package. Air, especially the oxygen ($O_2$) portion of air, can have negative effects on the package contents and its freshness. The most common application of the one-way degassing valve is for fresh roasted coffee. Demands of one-way degassing valves have been increasing with the high growth of global coffee market. In this study, we have developed one-way degassing valves for coffee and food packaging using ring type rubber disk, named SP valve. Its quality and performance was verified with test results to be equal with that of global top maker's product, Goglio valve. SP valves showed 820~1200 Pa of opening pressure, 10~50 Pa of closing pressure, 1.2~1.6 L/ min of flow rate. And, the SP valve applicable to ferment food packaging is expected to contribute to globalize Korean traditional food.

  • PDF

Analyses of Plantar Foot Pressure and Static Balance According to the Type of Insole in the Elderly

  • Bae, Kang-Ho;Shin, Jin-Hyung;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin;Park, Seung-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.115-126
    • /
    • 2016
  • Objective: The purpose of this study was to investigate plantar foot pressure and static balance according to the type of insole in the elderly. Methods: Thirteen elderly (mean age: $67.08{\pm}2.25years$, mean height: $159.63{\pm}9.64cm$, mean body weight: $61.48{\pm}9.06kg$) who had no previous injury experience in the lower limbs and a normal gait pattern participated in this study. Three models of insoles of the normal, 3D, and triangle types were selected for the test. The Pedar-X system and Pedar-X insoles, 3.3 km/h of walking speed, and a compilation of 20 steps walking stages were used to analyze foot-pressure distribution. Static balance test was conducted using Gaitview AFA-50, and balance (opening eyes, closing eyes) was inspected for 20 s. One-way ANOVA was conducted to test the significance of the results with the three insoles. p-value of less than .05 was considered statistically significant. Results: The mean foot pressure under the forefoot regions was the lowest with the 3D insole during treadmill walking (p<.05). The mean value under the midfoot was the highest with the 3D insole (left: p<.05, right: p<.01). The mean value under the rearfoot was the lowest with the 3D insole (p<.001). The maximum foot pressure value under the foot regions was the lowest on both sides of the forefoot with the 3D insole. A statistically significant difference was seen only in the left foot (p<.01). The maximum value under the midfoot was the highest with the 3D insole (p<.001). No statistically significant difference was detected on the values under the rearfoot. In the case of vertical ground reaction force (GRF), statistically significant difference was seen only in the left side rearfoot (p<.01). However, static balance values (ENV, REC, RMS, Total Length, Sway velocity, and Length/ENV) did not show significant differences by the type of insole. Conclusion: These results show that functional insoles can decrease plantar pressure and GRF under the forefoot and rearfoot. Moreover, functional insoles can dislodge the overload of the rearfoot and forefoot to the midfoot. However, functional insoles do not affect the static balance in the elderly.

Effect of Oral Motor Facilitation Technique on Oral Motor Function in Stroke Patients (구강운동촉진기술(Oral Motor Facilitation Technique)이 뇌졸중 환자의 구강운동기능에 미치는 효과)

  • Son, Yeong Soo;Min, Kyoung Chul;Woo, Hee-Soon
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.4
    • /
    • pp.135-151
    • /
    • 2023
  • Objective : This study was conducted to confirm the effect of the oral motor facilitation technique (OMFT) on oral motor function in stroke patients. Methods : This study was conducted on 72 stroke patients with dysphagia were included. Thirty-six patients were randomly assigned to the experimental and control groups were randomly classified into 36 patients each using a random table, and a two-group pre-post test was designed. The experimental group underwent OMFT, and the control group underwent traditional dysphagia therapy for 30 min, once a day, 5 times a week for 4 weeks, for a total of 20 sessions. The Comprehensive Orofacial Function Scale (COFFS) was used to evaluate oral motor function. Repeated-measures analysis of variance (ANOVA) was performed to confirm the effect of the period, and an independent t-test was performed to analyze the difference in change between the two groups. Results : Total COFFS scores improved in both groups. The experimental group showed significant changes in mandibular and lip movements, cheek blows, and tongue movements. In addition, there were significant differences depending on the intervention period in terms of masticatory distribution, food spillage, swallowing of solid and liquid foods, and voice changes. There were significant differences in the mandibular opening and closing categories between the two groups. Conclusion : OMFT is effective in improving oral motor function in stroke patients with dysphagia and can be used as basic evidence in clinical practice.

The Effect of Data Size on the k-NN Predictability: Application to Samsung Electronics Stock Market Prediction (데이터 크기에 따른 k-NN의 예측력 연구: 삼성전자주가를 사례로)

  • Chun, Se-Hak
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.3
    • /
    • pp.239-251
    • /
    • 2019
  • Statistical methods such as moving averages, Kalman filtering, exponential smoothing, regression analysis, and ARIMA (autoregressive integrated moving average) have been used for stock market predictions. However, these statistical methods have not produced superior performances. In recent years, machine learning techniques have been widely used in stock market predictions, including artificial neural network, SVM, and genetic algorithm. In particular, a case-based reasoning method, known as k-nearest neighbor is also widely used for stock price prediction. Case based reasoning retrieves several similar cases from previous cases when a new problem occurs, and combines the class labels of similar cases to create a classification for the new problem. However, case based reasoning has some problems. First, case based reasoning has a tendency to search for a fixed number of neighbors in the observation space and always selects the same number of neighbors rather than the best similar neighbors for the target case. So, case based reasoning may have to take into account more cases even when there are fewer cases applicable depending on the subject. Second, case based reasoning may select neighbors that are far away from the target case. Thus, case based reasoning does not guarantee an optimal pseudo-neighborhood for various target cases, and the predictability can be degraded due to a deviation from the desired similar neighbor. This paper examines how the size of learning data affects stock price predictability through k-nearest neighbor and compares the predictability of k-nearest neighbor with the random walk model according to the size of the learning data and the number of neighbors. In this study, Samsung electronics stock prices were predicted by dividing the learning dataset into two types. For the prediction of next day's closing price, we used four variables: opening value, daily high, daily low, and daily close. In the first experiment, data from January 1, 2000 to December 31, 2017 were used for the learning process. In the second experiment, data from January 1, 2015 to December 31, 2017 were used for the learning process. The test data is from January 1, 2018 to August 31, 2018 for both experiments. We compared the performance of k-NN with the random walk model using the two learning dataset. The mean absolute percentage error (MAPE) was 1.3497 for the random walk model and 1.3570 for the k-NN for the first experiment when the learning data was small. However, the mean absolute percentage error (MAPE) for the random walk model was 1.3497 and the k-NN was 1.2928 for the second experiment when the learning data was large. These results show that the prediction power when more learning data are used is higher than when less learning data are used. Also, this paper shows that k-NN generally produces a better predictive power than random walk model for larger learning datasets and does not when the learning dataset is relatively small. Future studies need to consider macroeconomic variables related to stock price forecasting including opening price, low price, high price, and closing price. Also, to produce better results, it is recommended that the k-nearest neighbor needs to find nearest neighbors using the second step filtering method considering fundamental economic variables as well as a sufficient amount of learning data.

Development of Two-Dimensional Scanning Videokymography for Analysis of Vocal Fold Vibration

  • Wang, Soo-Geun;Lee, Byung-Joo;Lee, Jin-Choon;Lim, Yun-Sung;Park, Young Min;Park, Hee-June;Roh, Jung-Hoon;Jeon, Gye-Rok;Kwon, Soon-Bok;Shin, Bum-Joo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.2
    • /
    • pp.107-111
    • /
    • 2013
  • Objectives : We developed two-dimensional (2D) scanning videokyomography to evaluate the mucosal wave of whole vocal cords in real time to overcome the limit of preexisting stroboscopy and line scanning videokymography which could not evaluate it. Methods : We implemented a continuous light source with high brightness, a high-definition CMOS camera, and capture board for saving the data. We created the software program to analyze the image data from the system. The test of the functionality of the 2D scanning videokymography camera was performed in one of the authors (P.H.J 32 years old male). Vocal cord images were obtained during normal phonation and falsetto phonation. Images were obtained also during cough, diplophonia. Results : The system made it possible to measure objective parameters, including fundamental frequency, amplitude, regularity, mucosal wave, and phase difference, medial and lateral peak, opening versus closing duration related to vocal fold vibration. Simultaneously, it enabled analysis of the whole mucosal wave of the entire vocal fold in real time. 2D scanning videokymography was also effective for evaluating the dynamic status of the vocal fold when the subject phonated aperiodic voice. Conclusion : In conclusion, 2D scanning videokymography can support the analysis of the whole mucosal wave of the entire vocal cord with objective vocal parameters, overcoming the limitations of stroboscopy and previous line scanning videokymography techniques.

  • PDF

Structural Analysis of Damping Hinge for Built-in Side-by-Side Refrigerator and Design Improvement of Bracket Pin to Reduce Stress Concentration (빌트인 양문형 냉장고 댐핑힌지의 구조해석 및 브래킷핀의 응력집중 저감을 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.373-379
    • /
    • 2020
  • This study performed stress and fatigue life analysis of the damping hinge of a built-in side-by-side refrigerator that occurs when the door is opened to the maximum angle. An analysis of the initial design showed that stress concentration occurred at the corner between the cylinder and upper disk of the bracket pin, and the maximum stress exceeded the yield strength. The maximum stress location and the calculated fatigue life were consistent with the door opening-and-closing endurance test results for a prototype. Three cases of design improvement for the bracket pin were derived with the aim of reducing the stress concentration that appeared in the initial design. An analysis of the cases showed that inserting a fillet between the disk and the cylinder of the bracket pin reduced the stress and increased the fatigue life. Moreover, changing the disk into two steps was more favorable. In conclusion, the best design improvement was the case that the disk was changed to two steps and the fillet with a large radius was inserted. In that case, the stress was the smallest and the fatigue life was infinite.

Forecasting Power of Range Volatility According to Different Estimating Period (한국주식시장에서 범위변동성의 기간별 예측력에 관한 연구)

  • Park, Jong-Hae
    • Management & Information Systems Review
    • /
    • v.30 no.2
    • /
    • pp.237-255
    • /
    • 2011
  • This empirical study is focused on practical application of Range-Based Volatility which is estimated by opening, high, low, closing price of overall asset. Especially proper forecasting period is what I want to know. There is four useful Range-Based Volatility(RV) such as Parkinson(1980; PK), Garman and Klass(1980; GK) Rogers and Satchell(1991; RS), Yang and Zhang(2008; YZ). So, four RV of KOPSI 200 index during 2000.5.22-2009.9.18 was used for empirical test. The emprirical result as follows. First, the best RV which shows the best forecasting performance is PK volatility among PK, GK, RS, YZ volatility. According to estimating period forcasting performance of RV shows delicate difference. PK has better performance in the period with financial crisis of sub-prime mortgage loan. if not, RS is better. Second, almost result shows better performance on forecasting volatility without sub-prime mortgage loan period. so we can say that forecasting performance is lower when historical volatiltiy is comparatively high. Finally, I find that longer estimating period in AR(1) and MA(1) model can reduce forecasting error. More interesting point is that the result shows rapid decrease form 60 days to 90 days and there is no more after 90 days. So, if we forecast the volatility using Range-Based volaility it is better to estimate with 90 trading period or over 90 days.

  • PDF

Simulation of Water Quality Changes in the Saemangeum Reservoir Induced by Dike Completion (방조제 완공에 따른 호내부 수질변화 모의)

  • Suh, Seung-Won;Lee, Hwa-Young;Yoo, Sang-Cheol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.258-271
    • /
    • 2010
  • In order to figure out hydrodynamic and water quality changes after completion of dike construction of the Saemangeum, which behaves as a semi-enclosed estuarine lake, numerical simulations based on fine grid structure by using EFDC were intensively carried out. In this study some limitations of precedent study has been improved and gate operation were considered. Also 3 phases such as air-water-sediment interaction modeling was considered. It is clear that inner mixing of the Saemangeum is dominated by Mankyeong and Dongjin riverine discharges rather than the gate opening influence through the Lagrangian particle tracking simulations. Vertical DO structure after the dike completion shows steep gradient especially at Dongjin river estuary due to lessen of outer sea water exchange. Increasing SOD at stagnantly changed man-made reservoir might cause oxygen deficiency and accelerating degradation of water quality. According to TSI evaluation test representing eutrophication status, it shows high possibility of eutrophication along Mankyeong waterway in spite of dike completion, while the index is getting high after final closing along Dongjin waterway. Numerical tests with gate operations show significant differences in water quality. Thus it should be noted that proper gate operation plays a major role in preserving target water quality and management for inner development plan.

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.