• Title/Summary/Keyword: opening and closing test

Search Result 80, Processing Time 0.031 seconds

A Method on Safety Assessment of Shell-type Roller Gate (쉘타입 로울러게이트의 안전성평가 방법)

  • Chung, Jee-Seung;Jung, Hae-Wook;Lim, Hyung-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.92-98
    • /
    • 2015
  • This paper was carried out to prove the relation between static loads acting on the sluice(hydrostatic) and dynamic loads (additional loads) arising from opening or closing of sluice, through measuring the operation of shell-type roller gate by using the method of measuring of the completely opening water gate, as measured from one excitation state, it was confirmed to be capable of measuring the natural frequency reliable measurement results. Throughout the test, we prove that it's a reasonable way to estimate the default margin of safety when calculated by dividing the sum of the hydrostatic stress to the maximum stress and additional stress. The application of this paper's safety estimation method can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.

Development of Automatic Packing System of One Station for Fasteners(I): Optimization Design of Packing Mechanism (원 스테이션 파스너 자동포장기 개발(I): 패킹 메커니즘의 최적설계)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.335-341
    • /
    • 2011
  • In this paper, we proposed an automatic packing mechanism of one station concept for fastener objects where the continuous work is performed in a finite space. The proposed packing mechanism is composed of supporting frame, feeding supply, air shower device, clamping/opening device, batch charging device, sealing/cutting device and supply adjusting device. And, these mechanisms have been modularized through mechanical, dynamical, structural and fluid optimized design using the SMO(SimDesigner Motion) analysis module. Also, the virtual prototype was carried out using the 3-D CAD program. The packing process is consisted performed in the order of feeding, clamping, bottom sealing, cutting, opening, object charging, closing and the upper sealing. And the time of these cycles were designed to be completed in 15-20 seconds. This packing mechanism will be created as a prototype in the near future. In addition, it will be applied to the production scenes after going through a field test for the validation of performance.

Development of a Car Door Checker for Reducing Noise in Opening (승용차 도어의 개폐 이음 저감을 위한 도어체커 개발)

  • An, Byeongju;Son, Sungmin;Yun, Jaedeuk;Jung, Yoongho;Kim, Hyongdon;Shin, Jongil;Seo, Seungwoo;Jang, Kookjin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.396-401
    • /
    • 2015
  • A door checker holds a car door at several opening angles and limits the maximum door opening, so that the door does not bump against to passengers. Recently, the performance of door checker becomes more important as the feeling of door opening and closing effects on the quality of a car. However, some of door checkers make squealing noise when they are used for ages, which causes consumer's complaints as well as decreasing commercial value of the product. In this study, after various experiments for the noise, we concluded that the major reasons of the noise are acceleration of wearing and loss of lubricant due to impurities in working parts. Therefore, we developed a new mechanism of door checker which can resolve the major reasons of the noise. The developed mechanism is effective to prevent inflow of impurities and loss of lubricant by locating working parts in the case. We also proved that the developed mechanism does not make any noise after the test of 50,000 times of operations.

Accelerated Life Test Design of an Electromagnetic Shielding Door Hinge (전자파 차폐도어용 힌지의 가속 수명 시험법 설계)

  • Kim, Do Sik;Cheong, Han Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.887-895
    • /
    • 2017
  • This paper presents a study on the accelerated life tests of parts that operate during the opening and closing of door frames, particularly door hinges. Hinge theoretical verification and validation of the test equipment in the present study and the different structures and fault mode, depending on the purpose of usage analysis, failure mode for one of the hinges of the switchgear components used for electromagnetic shielding facilities and on-site operating conditions. The accelerated life test was designed for the characteristic lifetime prediction of the components, by estimating the shape parameter and the acceleration factor.

Study on Characteristics of Nipple Fracture for Fluid Path Control of 3-Way Ultra-High Pressure Valve (3-way 초고압 밸브의 유로제어를 위한 니플 파단 특성에 관한 연구)

  • Kang, Dae-Hee;Ranjit, Shrestha;Chung, Yoon-Jae;Kim, Won-Tae
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.865-871
    • /
    • 2018
  • The 3-way valve have been used as a valve for opening and closing the valve by the flow control in the pressure system of the cryogenic and high pressure environment. In this paper, numerical analysis and experimental study on fracture nipple of 3-way ultra high pressure valve applied to space launch vehicle was carried out. We have developed a 3-way valve numerical simulation modeler of cryogenic environment using commercial software ANSYS 18.2. As results of numerical analysis, optimum nipple condition was derived. In addition, a 3-way valve prototype was fabricated and the fracture test was performed and compared with the numerical analysis results.

Design and Development of Large Electric Curtain Control System for Time Controlled (대형전동커튼 타임제어 시스템 설계 및 개발)

  • Cheng, Shuo;Chung, Yong Taek;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.1-6
    • /
    • 2019
  • The purpose of this paper is to design a curtain control system for centralized management of large curtains, which includes curtain structure, electric curtain controller, communication system, user interface and remote control. Curtain structure is designed to avoid using limit switch. The system is based on microprocessor, determined the stop position and complete running time of electric curtain through time control, and achieved remote control of curtain opening and closing through wired and wireless communication modes. By establishment of a mathematical model to calculate the inertia compensation time of the electric curtain, the electric curtain can be stopped ahead of time, and the curtain can be completely closed by the inertia. The result of test experiment of 32 electric curtain controllers shows the communication success rate reached 100%.

Fluid-Structure Interaction Analysis for Pulsation Damping in Fuel Rail (연료 레일에서의 맥동저감을 위한 유체-구조 상호작용 해석)

  • Shim, Jeong-Yeon;Kim, Dong-Hyun;Cho, Yun-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.813-816
    • /
    • 2006
  • Complex pressure pulsation phenomenon in fuel rails is generated by rapid opening and closing of injectors and it commonly causes undesirable noise. In this study, fluid-structure interaction analyses based on CFD and FEM have been conducted to examine the pulsation damping characteristics for different shapes of fuel rails. It is shown from the present results that the fuel rail with a high aspect ratio rectangular cross section seems to be best in order to reduce the pressure pulsations. It also agrees well with the previous experimental test by Mizuno, K. et al.

  • PDF

Abrasion of abutment screw coated with TiN

  • Jung, Seok-Won;Son, Mee-Kyoung;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.102-106
    • /
    • 2009
  • STATEMENT OF PROBLEM. Screw loosening has been a common complication and still reported frequently. PURPOSE. The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS. Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated poly-esther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS. TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION. Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.

A Development of Measurement System for Diathesis-Diagnosis (체질 진단을 위한 센서 시스템의 개발)

  • Jung, Yong-Rae;Kim, Seong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.260-263
    • /
    • 2001
  • This paper is to develop the sensing system for opening-force measurement such as O-Ring muscular meridian. We designed to overcome the functional limit that the conventional force-sensor can measure just the closing-force. Therefore, the new sensor can meet a variety of application as well as O-Ring test. The structure of the new sensor is an actuator-type system using an electromagnet. That is made up of mechanical system, electromagnet, current transformer and computer interface circuit. Driving software and user interface program of the new sensor system also is explained in this paper.

  • PDF

Stress Analysis and Design Improvement to Prevent Failure of the Damping Hinges of Built-in Refrigerators (빌트인 냉장고 댐핑힌지의 응력해석 및 파손방지를 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.81-88
    • /
    • 2020
  • The damping hinge of a built-in refrigerator was examined in terms of its stress and fatigue life. Analysis of the initial design showed that stress concentration occurred at the concave surface of the hinge lever, which was broken during the door opening-and-closing endurance test of the prototype. The maximum von Mises stress at this location exceeded the yield strength. In addition, Goodman fatigue analysis of the initial design showed that the fatigue life at this location was consistent with the failure observed during the endurance test. Based on these results, an improved design for the damping hinge was derived. Analysis of this improved design showed that the stress concentration in the hinge lever of the initial design was eliminated. In this case, the maximum stress occurred at the position where the hinge lever was in contact with the door stopping pin, and the maximum von Mises stress was smaller than the yield strength. Goodman fatigue analysis of the improved design indicated that the fatigue life of the entire damping hinge was infinite. It was therefore concluded that the improved design does not suffer from fatigue damage during the endurance test.