Browse > Article
http://dx.doi.org/10.3795/KSME-A.2017.41.9.887

Accelerated Life Test Design of an Electromagnetic Shielding Door Hinge  

Kim, Do Sik (Reliability Assessment Center, Korea Institute of Machinery & Materials)
Cheong, Han Young (Reliability Assessment Center, Korea Institute of Machinery & Materials)
Publication Information
Transactions of the Korean Society of Mechanical Engineers A / v.41, no.9, 2017 , pp. 887-895 More about this Journal
Abstract
This paper presents a study on the accelerated life tests of parts that operate during the opening and closing of door frames, particularly door hinges. Hinge theoretical verification and validation of the test equipment in the present study and the different structures and fault mode, depending on the purpose of usage analysis, failure mode for one of the hinges of the switchgear components used for electromagnetic shielding facilities and on-site operating conditions. The accelerated life test was designed for the characteristic lifetime prediction of the components, by estimating the shape parameter and the acceleration factor.
Keywords
Hinge; Load; Wear; Failure; Accelerated Life Test;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 KS F 2236, 1999, "Doorsets - Soft Heavy Body Impact Test," Korean Standard Association.
2 KS F 2630, 2007, "Doorsets - Static Torsion Test," Korean Standard Association.
3 KS F 2631, 2007, "Doorsets - Vertical Load Test," Korean Standard Association.
4 KS F 2632, 2007, "Doorsets - Repeated Opening and Closing Test," Korean Standard Association.
5 KS F 2634, 2000, "Doorsets - Static Loading Test," Korean Standard Association.
6 KS F 3109, 2013, "Doorsets," Korean Standard Association.
7 UFGS-13 27 54.00 10, 2007, "Special Construction - Electromagnetic Shielding," United State Army Corps of Engineers.
8 MIL-STD-188-125, 1998, "High-Altitude Electromagnetic Pulse (HEMP) Protection for Ground-based C4I Facilities Performing Critical, Time-Urgent Missions for Common Long-Haul/Tactical Communication Systems," USA Department of Defense.
9 IEEE 299, 1997, Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures, The Institute of Electrical and Electronics Engineers.
10 Reliabiliy Assessment Criteria, 2013, "Electromagnetic Sheilding Doorsets," RS-KIMM-2013-0195.
11 Shin, J. H., Lee, H. K., Jang, J., Kim, D. S., Nam, T. Y. and Jung, D. S., 2014, "Reliability Demonstration Test Method for Electromagnetic Shielding Doorset with a Sub-unit Subjected to Preventive Replacement," Trans. Korean Soc. Mech, Eng. A, Vol. 38, No. 10, pp. 1171-1177.   DOI
12 Lee, J. H., Kim, D. S., Chang, M.S. and Cho, H. Y., 2015, "Accelerated Life Testing and Validity Evaluation of Finger Strips used for Electromagnetic Shielding Doors," Trans. Korean Soc. Mech, Eng. A, Vol. 39, No. 9, pp. 831-837.   DOI
13 Jeong, H. S., 2007, "A Study on Optimal of Accelerated Life Tests," International Research of Reliability Application, Vol. 7, No. 2, pp. 57-72.
14 Wasserman, G. S., 2003, Reliablity Verification, Testing and Analysis in Engineering Design, Marcel Dekker, New York.
15 Nelson, W., 1990, Accelerated Testing; Statistical Models, Test Plans, and Data Analysis, Wiley, New York.