• 제목/요약/키워드: opening and closing test

Search Result 80, Processing Time 0.029 seconds

Thin Bonded Concrete Overlay for Concrete Pavement Rehabilitation (콘크리트포장의 박층 콘크리트 덧씌우기공법)

  • 윤경구;이형준;엄주용;서영찬
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.635-642
    • /
    • 1997
  • This research focused on the development of concrete overlay and test, which was conducted at 88 Highway 105k, 2 lanes of 290 m. The field application test consists of 6 cm and 10 cm bonded concrete overlay and 25 cm unbonded concrete overlay, using the slag cement for opening lanes for traffic early. The overlay were placed in a day. The whole period of traffic closing wes 8 day and it was reopened to traffic after concrete overlay has cured for 3 day. 5 cracks were founded when the field test section was investigated after 1 month, but all these may not make significant problems to overlay because these initiated and growed at the same line of repair section. The rideability and skid resistance become much better like in the new pavement after overlay. The structural capacity against deflection was much. which were verified by FWD(Falling Weight Deflectometer). The field test section is being used in a good condition and the results of field application and pavement performance analysis are encouraging. This rehabilitation methods may be adopted in Korea after a more field performance verifications.

  • PDF

The Development of Gas Bushing for 25.8kV/2000A GCB (25.8kV 2000A GCB용 개스붓싱 개발)

  • Kim, J.B.;Song, W.P.;Lee, C.H.;Noh, C.W.;Jang, W.Y.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1385-1387
    • /
    • 1994
  • For the development of the 25.8kV outdoor GCB (Gas - Circuit - Breaker), which have a surge surpression performance in closing & opening of circuit and a high reliability performance, we have developed the 25.8kV gas bushing first of all in KOREA. After manufacturing of 25.8kV/2000A gas bushing, we carried out the dimension & visual test and electrical & mechanical test and we have got the favorable test-results. And it was put together real outdoor GCB, and then we carried out type test at KERI and have confirmed the performance of this bushing.

  • PDF

Reliability Assessment on the Indoor Vacuum Circuit Breaker Used in Distribution System (배전급 옥내용 진공차단기의 신뢰성평가)

  • Kim, Min-Kyu;Kim, Maeng-Hyun;Shin, Young-June
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.160-163
    • /
    • 2003
  • This paper represent a test method for the reliability assessment on the indoor vacuum circuit breakers used in the distribution system by an accelerated life test. In order to guarantee the lifetime in service of the vacuum circuit breaker, additional test methods are suggested. Multiple closing-opening operation test under no load condition as a mechanical endurance test and a check of the quality in the vacuum interrupter are adopted to assure the long-term reliability of the vacuum circuit breaker.

  • PDF

Comparison of Heat Insulation Characteristics of Multi-layer Thermal Screen and Development of Curtain System (다겹보온자재의 보온성 비교 및 커튼개폐장치 개발)

  • Lee, Si-Young;Kim, Hark-Joo;Chun, Hee;Yum, Sung-Hyun;Lee, Hyun-Joo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • This study was accomplished to compare energy saving effects of several heat insulation materials in greenhouse and to develop new automatic opening and closing equipment which is suitable to the most effective heat insulation material. To find out more effective heat insulation material, the magnitude of heat transfer occurred through aluminum screen (ALS), non-woven fabric (NWF), double-layer aluminum screen with chemical cotton sheet (DAL), and multi-layer fabric screen material quilted with non-woven fabric, chemical cotton, poly foam, and polypropylene (MLF) were compared relatively. The results showed that the relative magnitude of heat transfer occurred through MLF was lower than DAL and ALS by 23.3% and 43.0% respectively. MLF screen material was the most effective compared with other heat insulation materials. But because of thickness, there was a need of new mechanism for automatic operation in greenhouse. Accordingly, new screen system using MLF-thick but profitable for keeping warm in greenhouse-was developed. Opening & closing equipment was designed to roll MLF with pipe axis during opening process and pull MLF with string during closing process with electric motors, clutches, drums, and so on. In hot pepper cultivation and energy saving test during winter time, the early stage yield of pepper under MLF screen system was higher than NWF by 27%, and gasoline consumption of MLF screen system was lower than NWF by 46%.

Wear Reduction of Tappet Surface by Undulated Surface (미세요철표면을 이용한 태핏 표면의 마모 저감에 관한 연구)

  • 여창동;김대은
    • Tribology and Lubricants
    • /
    • v.14 no.2
    • /
    • pp.63-74
    • /
    • 1998
  • The damage of cam/tappet surface is one of the major reasons for energy loss in an I.C. engine. High friction causes the accelerated wear of the cam/tappet surfaces which in turn changes the valve opening/closing timing. During the accelerated test evidence of both rolling fatigue and sliding abrasive wear could be found. Based on the results of the accelerated test, a scheme was devised to decrease tappet wear. Wear reduction of the tappet was achieved by using undulated surface topography in the tappet center region. The wear reduction is achieved by trapping of the wear particles in the undulations as well as by increasing the supply of lubricant to the sliding interface.

Development of the Controlled Switching Device for a Cirrcuit Breaker

  • Kim, Ik-Mo;Kim, Myung-Chan;Choi, Young-Chan;Ryu, Sung-Sic;Kim, Dong-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.558-560
    • /
    • 2004
  • Studies on the controlled switching method have been done to prevent the power system surges which cause the insulation deterioration and electro magnetic compatibility (EMC) problems during closing and opening of a circuit breaker. The controlled switching method controls the closing and tripping time in coincidence with the voltage or current to suppress switching surge. It is used to switch condenser bank, no load transformer, and shunt reactor. In this study, basic concept of the controlled switching is introduced, and also the test is performed to find parameters of the controlled switching in a 24kV vacuum circuit. And then, the control device hardware using TMS320C31 DSP has been designed and manufactured. It has been found that the application of IT technology to a circuit breaker is very effective to depress the switching surge.

  • PDF

The Effect of 3 Balance Training Programs on Improving Capabilities of Balancing among Some Female Students (일부 여대생의 세 가지 균형조절 훈련 효과 비교)

  • Yu, Jin-Ho;Jeong, Sun-Mi;Park, Hyung-Su
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.4
    • /
    • pp.619-629
    • /
    • 2013
  • This study was conducted to compare the effect improving balance abilities of 3 balance training programs by randomized intervention trial. Study subjects were 29 female students recruited from a university in Gwanju, who allocated randomly to 3 intervention groups, aqua group(modified Halliwick 10 point program, N=10), visual bio-feedback balance training group(N=10), and balance-pad plus trampolin group(N=9). As the results of repeated musure ANOVA, Wilcoxon signed rank test, major research findings were as follows; 1. Regarding SI or BIEMG measured at upright posture on hard platform, bio-feedback group under the condition with opening both eye and aqua group under the condition with closing both eye showed signigicant improvement in balance ability, respectively. 2. Regarding SI or BIEMG measured at upright posture on soft platform, bio-feedback group under the condition with opening both eye and aqua group under the condition with closing both eye showed signigicant improvement in balance ability, respectively. 3. Regarding all 3 sensory ratios, bio-feedback group showed significantly higher increasement in them than other 2 groups. The results suggested that visual bio-feedback training program improve the all 3 sensory functions required for balancing, and aqua training modified from Halliwick 10 point program contribute to improve vestibular function principally.

Burst Test and Finite Element Analysis for Failure Pressure Evaluation of Nuclear Power Plant Pipes (원전 배관 손상압력 평가를 위한 파열시험 및 유한요소해석)

  • Yoon, Min Soo;Kim, Sung Hwan;Kim, Taesoon
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.144-149
    • /
    • 2015
  • This study aims to quantitatively evaluate failure pressure of wall-thinned elbow under combined load along with internal pressure, by conducting real-scale burst test and finite element analysis together. For quantitative evaluation, failure pressure data was extracted from the real-scale burst test first, and then finite element analysis was carried out to compare with the test result. For the test, the wall-thinning defect of the extrados or intrados inside the center of 90-degree elbow was considered and the loading modes to open or close the specimen maintaining a certain load or displacement were applied. Internal pressure was applied until failure occurred. As a result, when the bending load was applied under the load control condition, the intrados of the defect was more affected by failure pressure than the extrados, and the opening mode was more vulnerable to failure pressure than the closing mode. When the bending load was applied under the displacement control, it was hardly affected by failure pressure though it was slightly different from the defect position. The result of the finite element analysis showed a similar aspect with the test. Moreover, when major factors such as material properties and pipeline thickness were calibrated to accurate values, the analytical results was more similar to the test results.

Opening Exercise Therapy with Locking-free Appliance(LA) : Preliminary Study (Locking-free Appliance(LA)를 이용한 개구운동치료 : 예비실험)

  • Jung, Won;Lee, Kyung-Eun;Sun, Sae-Ah;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • Objective: All patients who have the disc displacement with reduction (DDwR) are always not progressive but some of them with significant catching or locking progress to disc displacement without reduction (DDw/oR). In this study, we suggest opening exercise therapy using Locking-free Appliance (LA) to be helpful to prevent progressive derangement. Methods: Retrospectively, a total 37 patients who received exercise treatment using LA was analyzed from January 2010 to December 2011. Patients had been instructed in proper exercise technique to practise for opening and closing of mouth wearing the appliance 30 times a day in locking-free position. Results: None of the patients took a turn for worse to DDw/oR (37 patients). The 16 patients (43.2%, locking-free group) of them could open their mouth without intermittent condylar locking. Measurement of data was analyzed using and Mann-Whitney test. There was no statistically significant difference for age, gender, presence of palpational pain, locking period, VAS quantitative pain score between locking-free group and locking group. Conclusions: In this study, some patients could open their mouth without intermittent locking and did not take a turn for worse to DDw/oR after opening exercise therapy with LA. Furthermore, LA had advantages which were short wearing time, low costs and minimizing patients' uncomfortable compared to conventional treatment method. This therapy can be more appropriate new treatment to prevent progress to DDw/oR.

A comparison of transcranial with panoramic TMJ radiographs to assess the movement of the mandibular condyle (하악과두 운동 평가를 위한 경두개방사선사진과 파노라마 TMJ 방사선사진의 비교)

  • Oh, Jong-Hwa;Kim, Jae-Duk;Kim, Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.38 no.2
    • /
    • pp.89-93
    • /
    • 2008
  • Purpose: To evaluate the difference of the movement of the mandibular condyles between trans cranial and panoramic TMJ radiographs to view the movement of the mandibular condyles. Materials and Methods: Thirty-four paired transcranial and panoramic TMJ radiographs of patients were used to evaluate the movement of the mandibular condyle. The distances, from the most superior point of the mandibular condyle to the most inferior point of the articular eminence on both radiographs, were measured. The measurements were taken at closed state and maximum opening state of each radiograph on both side. Differences between matched pairs were analysed by paired t-test, with significance established at P<0.05. Results and Conclusion: The mean distance, from the most superior point of the mandibular condyle to the most inferior point of the articular eminence on both radiographs, was statistically different at each side (P<0.05). At closing state, the mean distance measured on panoramic TMJ radiographs was longer than on transcranial radio-graphs (0.85 mm at right side, 1.20 mm at left side). But at maximum opening state, the mean distance on transcranial radiographs was longer (1.00 mm at right side, 0.62 mm at left side) than panoramic TMJ radiographs.

  • PDF