• Title/Summary/Keyword: open loop control

Search Result 457, Processing Time 0.03 seconds

Simple and Flexible Temperature Control System for Space Environment Test

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.29.1-29.1
    • /
    • 2008
  • The temperature control system which is using liquid and gaseous nitrogen has been known as the most economical system to simulate space temperature condition due to relatively not expansive price of the liquid nitrogen (less than 0.2 USD per liter). And, among these systems, the closed loop system which circulates compressed nitrogen gas come from sprayed liquid nitrogen by blower and makes a target temperature with heat from an electrical heater and flow rate of liquid nitrogen is prevail all over the world. But, this complete closed loop system requires expansive equipments such as blower, heater, and liquid nitrogen injector, and special maintenance on the system. Therefore, KARI is developing efficient and simple open loop system which utilizes liquid and gaseous nitrogen with eliminating a special blower and other expansive units. In this study, this open loop system with more efficiency and flexibility will be designed and introduced.

  • PDF

Feedback stabilization of linear systems with delay in control by receding horizon (지연요소를 갖는 시스템의 안정화 방법)

  • 권욱현
    • 전기의세계
    • /
    • v.28 no.5
    • /
    • pp.44-48
    • /
    • 1979
  • For ordinary systems the receding horizon method has beer proved by the author as a very useful and easy tool to find stable feedback controls. In this paper an open-loop optimal control which minimizes the control energy with a suitable upper limit and terminal control and state constraints is derived and then transformed to the closed-loop control. The stable feedback control law is obtained from the closed-loop control. The stable feedback control law is obtained from the closed-loop control by the receding horizon concept. It is shown by the Lyapunov method that the control law derived from the receding, horizon concept is asymtotically stable under the complete controllability condition. The stable feedback control which is similar to but more general than the receding horizon control is presented in this paper To the author's knowledge the control laws in this paper are easiest to stabilize systems with delay in control.

  • PDF

A Stator Flux Oriented V/f Control of Induction Motor in Low Speed Range

  • Kim Young-Real
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.466-469
    • /
    • 2001
  • In this paper, closed loop V/f control of induction motor has been implemented by the estimated speed. Closed loop V/f control improve the performance of induction motor drive system at low speed compared to open loop V/f control. However, closed loop V/f control need speed sensor. By using the estimated speed, closed loop V/f control is possible without speed sensor. Rotor speed is calculated from the difference between synchronous frequency and slip angular frequency. 3-phase voltage reference is obtained from synchronous frequency. And the PWM technique using space vector PWM is applied in this scheme. In the space vector PWM, effective time of 3-phase voltage reference is used to simplify the calculation of effective voltage time. This scheme is simple to implement and one chip microprocessor was used in experimental system.

  • PDF

Handling Deflection Limit in Open-Loop-Onset-Point PIO Analysis (Open-Loop-Onset-Point PIO 해석의 변위한계)

  • Park, Sang-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2010
  • A new treatment is proposed to handle a deflection limit in the open-loop-onset-point (OLOP), which is commonly used in the prediction of pilot in-the-loop oscillation (PIO) due to a rate saturation. The new approach is motivated by the frequency response of a stand-alone actuator in that, unlike the suggestion by the original OLOP procedure, the rate limit onset is not delayed to a higher frequency by a deflection limit. Indeed, if a feedback control loop is closed, the rate limit onset can be shifted to a lower frequency since the controller tends to react with larger commands when deflection limited. The amplitude of the command at this onset frequency is combined with the deflection limit to estimate the associated gain reduction in the open-loop-onset-point in the final step of the OLOP process. The comparison of the new approach with the previous method reveals that an inaccurate optimism which can occur in the previous method is corrected by the proposed treatment.

Vibration-free Control of Double Integrator Typed Motor via Loop Transfer Recovery (루프 전달 회복을 통한 이중 적분 모터의 무진동 제어)

  • Suh, Sang-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.900-906
    • /
    • 2010
  • This note proposes vibration-free motor control through modified LQG/LTR methodology. A conventional LQG/LTR method is a design tool in the frequency domain. However, unlike the conventional one, the proposed one is a time response based design method. This feature is firstly designed by parameterized settling time control gain through the target loop design procedure and the feature is secondly realized by loop transfer recovery. In order to show convergence to the target loop transfer functions, asymptotic behaviors of the open and the closed loop transfer functions are shown. At the conclusion, it is verified that the proposed method is robustly stable to parametric uncertainties through ${\mu}$-plot.

Stabilization of Multirate Sampled-Data Control Systems in Case of Open-Loop Unstable Plant (개루프 상태에서 플랜트가 불안정한 경우에 대한 멀티레이트 표본 데이터 제어 시스템의 안정화)

  • Son, Seok-Bo;Park, Sang-Hyeon;Kim, Yeong-Baek;Park, Chan-Sik;Lee, Sang-Jeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.7
    • /
    • pp.547-555
    • /
    • 2002
  • This paper proposes a stabilizing controller for the multirate sampled-data systems, which have a periodic output measurement scheme, in case of the open-loop unstable plant. A sufficient condition for maintaining observability in the multirate sampled-data systems is derived and a design strategy for filtered disturbance rejection is proposed. We also propose a design method for the plant output estimator. It is shown that the proposed pre-stabilizing controllers can stabilize the plant through the simulations. The proposed controller has IMC structure, and can be decomposed into the pre-stabilizing controller, the plant output estimator, the filtered disturbance estimator and the inverse of the fast pre-stabilized plant model. We assume that the plant is open-loop unstable and the disturbance consists of a sum of finite number of sinusoids with different frequencies. Some examples are presented for illustrations.

Sensitivity Analysis of input shaping filter designed in the Z-domain (Z-영역에서 설계된 입력성형필터의 민감도 해석)

  • Park, Un-Hwan;Lee, Jae-Won;Lim, Byoung-Duk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.8
    • /
    • pp.883-888
    • /
    • 1999
  • To obtain high positioning auccuracy for a long, flex bleman Ipulator, residual vibration must be removed from the tip motion. But it is difficult to control the vibration of low frequency. There are open-loop and closed loop methods in the elimination of the residual vibration. We inroduce input shaping technique has been used as a simple open-loop method of controlling the residual vibration of a flexible manipulator. Design of input shaper in the continuous time domain is complicated. This paper presents a new technique that designs input shaper in the z-domain and analyzes input shaping method in the z-domain. This technique is simple and easy to design input shaper.

  • PDF

Dedication Load Based Dispatching Rule for Load Balancing of Photolithography Machines in Wafer FABs (반도체 생산 공정에서 포토장비의 부하 밸런싱을 위한 Dedication 부하 기반 디스패칭 룰)

  • Cho, Kang Hoon;Chung, Yong ho;Park, Sang Chul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This research develops dispatching rule for a wafer FABs with dedication constraints. Dedication, mostly considered in a photolithography step, is a feature in a modern FABs in order to increase the yield of machines and achieve the advance of manufacturing technology. However, the dedication has the critical problem because it causes dedication load of machines to unbalance. In this paper, we proposes the dedication load based dispatching rule for load balancing in order to resolve the problem. The objective of this paper is to balance dedication load of photo machines in wafer FABs with dedication constraint. Simulation experiments show that the proposed rule improves the performance of wafer FABs as well as load balance for dedication machines compared to open-loop control based conventional dispatching rule.

Dynamic Characteristics of LIM controlled by constant V/f (V/f일정제어로 제어되는 LIM의 동특성)

  • Jang, S.M.;Jeong, H.G.;Kim, B.S.;Park, Y.T.;Jeong, Y.H.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.50-52
    • /
    • 1995
  • This paper deals with the dynamic characteristics of LIM which is controlled by constant V/f ratio and the characteristics of the Inverter acted as interface between the utility power system and LIM. Though open-loop control method is less reliable than closed-loop control method, it's commonly used because it is simple and cheap. This paper shows the consideration for dynamic characteristics of LIM under open-loop control and for Inverter.

  • PDF

On optimal correction of gunfire errors (포 사격오차의 최적 수정에 관한 연구)

  • 이양원;김영주;김경기;김경기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.109-112
    • /
    • 1989
  • Gun system operation is represented as a first-order Markov process, and an optimum linear filter is derived for closed-loop control of mean square error. Potential improvement is then estimated by contrasting the variance in performance and the auto correlation for open-loop system with that for the optimum linearly corrected process.

  • PDF